Skip to main content Skip to navigation
FITC Mouse Anti-Rat Granulocytes
製品詳細
Down Arrow Up Arrow


BD Pharmingen™
Rat (QC Testing)
Mouse IgM, κ
Not reported
Flow cytometry (Routinely Tested)
0.5 mg/ml
AB_395595
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation and Storage

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with FITC under optimum conditions, and unreacted FITC was removed. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
554907 Rev. 9
抗体の詳細
Down Arrow Up Arrow
HIS48

The HIS48 antibody reacts with an antigen found on all granulocytes. It is also found on cells of the erythroid lineage at various stages of maturation in bone marrow.

554907 Rev. 9
フォーマットの詳細
Down Arrow Up Arrow
FITC
Fluorescein (FITC) is part of the BD blue family of dyes. This is a small organic fluorochrome with an excitation maximum (Ex Max) at 494-nm and an emission maximum (Em Max) at 518-nm. FITC is designed to be excited by the Blue laser (488-nm) and detected using an optical filter centered near 520 nm (e.g., a 530/30-nm bandpass filter). Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
FITC
Blue 488 nm
494 nm
518 nm
554907 Rev.9
引用&参考文献
Down Arrow Up Arrow

Development References (1)

  1. van Goor H, Fidler V, Weening JJ, Grond J. Determinants of focal and segmental glomerulosclerosis in the rat after renal ablation. Evidence for involvement of macrophages and lipids. Lab Invest. 1991; 64(6):754-765. (Clone-specific). View Reference
554907 Rev. 9

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.