BB515 Mouse Anti-Human CD57
Clone NK-1 (RUO)
- Brand BD Horizon™
- Alternative Name B3GAT1; Beta-1,3-glucuronyltransferase 1; HNK1; LEU7; NK-1; GLCATP; GLCUATP
- Vol. Per Test 5 µl
- Isotype Mouse IgM, κ
- Reactivity Human (QC Testing)
- Application
Flow cytometry (Routinely Tested)
- Storage Buffer Aqueous buffered solution containing ≤0.09% sodium azide.
- Regulatory Status RUO
Regulatory Status Legend
Description
The NK-1 monoclonal antibody specifically reacts with a 110 kDa carbohydrate antigen associated with myelin-associated glycoprotein expressed on 7-35% of normal peripheral blood lymphocytes including a subset of natural killer cells, a subset of CD8-positive peripheral blood T cells, and on some neural tissues. CD57 is not expressed on granulocytes, platelets, red blood cells or thymocytes. The function of CD57 is still unclear, however, its expression on T-cell subets occurs in late immune responses.
The antibody was conjugated to BD Horizon BB515 which was developed exclusively by BD Biosciences. With an excitation max of 490 nm and an emission max of 515 nm, BD Horizon BB515 can be excited by the 488 nm laser and detected in a standard FITC set (e.g. 530/30-nm filter). This dye provides a much brighter alternative to FITC with less spillover into the PE detector.
Format
BB515 is a dye that was exclusively developed by BD Biosciences as a brighter alternative to FITC. This dye is up to seven times brighter than FITC and has less spillover into the PE channel. Due to similar excitation and emission properties, BB515, FITC, and Alexa Fluor® 488 cannot be used simultaneously.
Suggested Companion Products
Lysing Solution 10X Concentrate RUO (GMP)
100
Cat No: 349202
Lysing Buffer RUO
100 mL
Cat No: 555899
BB515 Mouse IgM, κ Isotype Control RUO
50 µg
Cat No: 564680
Stain Buffer (FBS) RUO
500 mL
Cat No: 554656
Stain Buffer (BSA) RUO
500 mL
Cat No: 554657
Brilliant Stain Buffer RUO
100 Tests
Cat No: 563794
Brilliant Stain Buffer RUO
1000 Tests
Cat No: 566349
BB515 Mouse Anti-Human CD57 NK-1 RUO
25 Tests
Cat No: 565945
APC Mouse Anti-Human CD3 UCHT1 (also known as UCHT-1; UCHT 1) RUO
100 Tests
Cat No: 555335
APC Mouse Anti-Human CD3 UCHT1 (also known as UCHT-1; UCHT 1) RUO
25 Tests
Cat No: 561810
APC Mouse Anti-Human CD3 UCHT1 (also known as UCHT-1; UCHT 1) RUO
500 Tests
Cat No: 561811
Brilliant Stain Buffer Plus RUO
1000 Tests
Cat No: 566385
Resources & Tools | ||||||
---|---|---|---|---|---|---|
Spectrum Viewer | Panel Designer | Spectrum Viewer | Download TDS | Regulatory Document Website |
Preparation and Storage
Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.
The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography.
The antibody was conjugated with BD Horizon™ BB515 under optimum conditions and unconjugated antibody was removed.
Product Notices
- This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
- An isotype control should be used at the same concentration as the antibody of interest.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
- Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
For optimal results, it is recommended to perform 2 washes after staining with antibodies. Cells may be prepared, stained with antibodies and washed twice with wash buffer per established protocols for immunofluorescence staining, prior to acquisition on a flow cytometer. Performing fewer than the recommended wash steps may lead to increased spread of the negative population.
For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes are used in the same experiment. Fluorescent dye interactions may cause staining artifacts which may affect data interpretation. The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349).