Skip to main content Skip to navigation
BV480 Mouse Anti-Human CD61
製品詳細
Down Arrow Up Arrow


BD OptiBuild™
Integrin β3; Integrin beta-3; GP3A; GPIIIa; ITGB3; ITB3
Human (Tested in Development)
Mouse IgG1, κ
Flow cytometry (Qualified)
0.2 mg/ml
III 866; IV P83; V T-124
3690
AB_2743904
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation and Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with BD Horizon BV480 under optimal conditions that minimize unconjugated dye and antibody.

推奨アッセイ手順

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes (including BD OptiBuild Brilliant reagents) are used in the same experiment.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions.  More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794).

Product Notices

  1. This antibody was developed for use in flow cytometry.
  2. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  3. Researchers should determine the optimal concentration of this reagent for their individual applications.
  4. An isotype control should be used at the same concentration as the antibody of interest.
  5. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  8. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  9. BD Horizon Brilliant Violet 480 is covered by one or more of the following US patents: 8,575,303; 8,354,239.
746624 Rev. 1
抗体の詳細
Down Arrow Up Arrow
VI-PL2

The VI-PL2 monoclonal antibody specifically binds to CD61. CD61 is a 105 kDa transmembrane glycoprotein that is also known as integrin β3 and platelet glycoprotein IIIa (GPIIIa or GP3A). It is expressed on platelets, megakaryocytes, osteoclasts and endothelia. Integrin β3 associates with gpIIa (CD41) to form the CD41/CD61 complex which mediates platelet adhesion and aggregation. CD61 also associates with CD51 to form the CD51/CD61 complex (vitronectin receptor). CD61 appears to bind to fibrinogen, fibronectin, vWF, vitronectin, and thrombospondin to mediate cell adhesion.

The antibody was conjugated to BD Horizon™ BV480 which is part of the BD Horizon Brilliant™ Violet family of dyes. With an Ex Max of 436-nm and Em Max at 478-nm, BD Horizon BV480 can be excited by the violet laser and detected in the BD Horizon BV510 (525/40-nm) filter set.  BV480 has less spillover into the BV605 detector and, in general, is brighter than BV510.

746624 Rev. 1
フォーマットの詳細
Down Arrow Up Arrow
BV480
The BD Horizon Brilliant Violet™ 480 (BV480) Dye is part of the BD Horizon Brilliant Violet™ family of dyes. This polymer-technology fluorochrome has an excitation maximum (Ex Max) of 440-nm and an emission maximum (Em Max) of 479-nm. Driven by BD innovation, BV480 is designed to be excited by the violet laser (405-nm) and detected using an optical filter centered near 480-nm (e.g., a 525/50 bandpass filter). The increased fluorescence intensity of BV480 and narrower emission spectra, make it a good alternative for BV510 or V500. Due to its excitation profile, BV480 will also has less cross-laser excitation with the UV laser, resulting in less spillover into UV channels compared to BV510. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BV480
Violet 405 nm
440 nm
479 nm
746624 Rev.1
引用&参考文献
Down Arrow Up Arrow

Development References (6)

  1. Kishimoto T. Tadamitsu Kishimoto .. et al., ed. Leucocyte typing VI : white cell differentiation antigens : proceedings of the sixth international workshop and conference held in Kobe, Japan, 10-14 November 1996. New York: Garland Pub.; 1997.
  2. Knapp W, Dorken B, Rieber P, Schmidt RE, Stein H, von dem Borne AE. CD Antigens 1989: Summary of Nomenclature System for Human Leacocyte Surface Antigens. Am J Pathol. 1989; 135(2):420-421. (Clone-specific: Flow cytometry). View Reference
  3. Lin G-X, Yang X, Hollemweguer E, et al. Cross-reactivity of CD antibodies in eight animal species. In: Mason D. David Mason .. et al., ed. Leucocyte typing VII : white cell differentiation antigens : proceedings of the Seventh International Workshop and Conference held in Harrogate, United Kingdom. Oxford: Oxford University Press; 2002:519-523.
  4. Mason D. David Mason .. et al., ed. Leucocyte typing VII : white cell differentiation antigens : proceedings of the Seventh International Workshop and Conference held in Harrogate, United Kingdom. Oxford: Oxford University Press; 2002.
  5. Modderman PW. Cluster report: CD61. In: Knapp W. W. Knapp .. et al., ed. Leucocyte typing IV : white cell differentiation antigens. Oxford New York: Oxford University Press; 1989:1025.
  6. Yu J-F, Yang X-F, Nguyen E, et al. Seventh HLDA Workshop—Cytokine Receptor Section: Flow cytometric analysis on 11 different target cells. In: Mason D. David Mason .. et al., ed. Leucocyte typing VII : white cell differentiation antigens : proceedings of the Seventh International Workshop and Conference held in Harrogate, United Kingdom. Oxford: Oxford University Press; 2002:275-278.
すべて表示する (6) 表示項目を減らす
746624 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.