V500 Rat Anti-Mouse TER-119/Erythroid Cells
Clone TER-119 (RUO)
- Brand BD Horizon™
- Alternative Name Lymphocyte antigen 76; Ly76; Ly-76; TER-119; Ter119
- Concentration 0.2 mg/ml
- Isotype Rat WI, also known as Wistar (outbred) IgG2b, κ
- Reactivity Mouse (QC Testing)
- Application
Flow cytometry (Routinely Tested)
- Immunogen Mouse Fetal Liver
- Entrez Gene ID 104231
- Storage Buffer Aqueous buffered solution containing protein stabilizer, glycerol and ≤0.09% sodium azide.
- Regulatory Status RUO
Regulatory Status Legend
Description
The TER-119 antibody specifically binds to a 52 kDa molecule associated with glycophorin A on cells of the erythroid lineage in embryonic yolk sac, fetal liver, newborn liver, adult bone marrow, adult peripheral blood, and adult lymphoid organs. The TER-119 antigen is expressed on erythroid cells from pro-erythroblast through mature erythrocyte stages, but not on cells with BFU-E or CFU-E activities. The TER-119 epitope is not detected on hematopoietic stem cells, lymphoid cells, myeloid cells, or erythroleukemia lines. The TER-119 mAb is a component of the "lineage cocktail" used in studies of hematopoietic progenitors to detect, or deplete cells committed to the hematopoietic lineages.
The antibody is conjugated to BD Horizon™ V500, which has been developed for use in multicolor flow cytometry experiments and is
available exclusively from BD Biosciences. It is excited by the Violet laser with an Ex max of 415 nm and Em Max at 500 nm. BD Horizon V500 conjugates emit at a similar wavelength to Amcyan yet exhibit reduced spillover into the FITC channel. For more information on BD Horizon V500, visit bdbiosciences.com/colors.
When compensating dyes in this spectral range (such as Horizon™ V500 and AmCyan), the most accurate compensation can be obtained using single stained cellular controls. Due to spectral differences between cells and beads in this channel, using BD CompBeads can result in spillover errors for V500 and AmCyan reagents. Therefore, the use of BD CompBeads or BD CompBeads Plus to determine spillover values for these reagents is not recommended. Different V500 reagents (e.g. CD4 vs. CD45) can have slightly different fluorescence spillover therefore, it may also be necessary to use clone specific compensation controls when using these reagents.
Format
BD Horizon™ V500 is a novel organic dye excited by the violet laser. This dye offers improved brightness over Pacific Orange™ and reduced spillover into the FITC channel when compared to AmCyan. BD Horizon V500 cannot be used simultaneously with AmCyan or Pacific Orange™.
Suggested Companion Products
Purified Rat Anti-Mouse CD16/CD32 (Mouse BD Fc Block™) 2.4G2 RUO
0.1 mg
Cat No: 553141
Purified Rat Anti-Mouse CD16/CD32 (Mouse BD Fc Block™) 2.4G2 RUO
0.5 mg
Cat No: 553142
V500 Rat IgG2b, κ Isotype Control RUO
0.1 mg
Cat No: 560784
Stain Buffer (FBS) RUO
500 mL
Cat No: 554656
APC Rat Anti-Mouse CD45 30-F11 RUO
0.1 mg
Cat No: 559864
APC Rat Anti-Mouse CD45 30-F11 RUO
25 mg
Cat No: 561018
Resources & Tools | ||||||
---|---|---|---|---|---|---|
Spectrum Viewer | Panel Designer | Spectrum Viewer | Download TDS | Regulatory Document Website |
Preparation and Storage
Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.
The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography.
The antibody was conjugated with BD Horizon™ V500 under optimum conditions, and unreacted BD Horizon™ V500 was removed.
Product Notices
- Please refer to www.bdbiosciences.com/pharmingen/protocols for technical protocols.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- BD Horizon V500 has a maximum absorption of 415 nm and maximum emission of 500 nm. Before staining with this reagent, please confirm that your flow cytometer is capable of exciting the fluorochrome and discriminating the resulting fluorescence.
- An isotype control should be used at the same concentration as the antibody of interest.