PE Mouse Anti-Human β2-Microglobulin
PE Mouse Anti-Human β2-Microglobulin
Flow cytometric analysis of β2-Microglobulin expression on peripheral blood lymphocytes. Whole blood was stained with either PE Mouse Anti-Human β2-Microglobulin (Cat. No. 551337; solid line histogram), or with PE Mouse IgM, κ Isotype Control (Cat. No.555584; dashed line histogram). Erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202). The fluorescence histograms were derived from gated events with the forward and side light-scattering characteristics of viable lymphocytes.
Flow cytometric analysis of β2-Microglobulin expression on peripheral blood lymphocytes. Whole blood was stained with either PE Mouse Anti-Human β2-Microglobulin (Cat. No. 551337; solid line histogram), or with PE Mouse IgM, κ Isotype Control (Cat. No.555584; dashed line histogram). Erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202). The fluorescence histograms were derived from gated events with the forward and side light-scattering characteristics of viable lymphocytes.
製品詳細
Down Arrow Up Arrow


BD Pharmingen™
Human (QC Testing)
Mouse IgM, κ
Flow cytometry (Routinely Tested)
20 µl
N/A
567
AB_394152
Aqueous buffered solution containing BSA, protein stabilizer, and ≤0.09% sodium azide.
RUO


Preparation and Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with R-PE under optimum conditions, and unconjugated antibody and free PE were removed.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
551337 Rev. 6
抗体の詳細
Down Arrow Up Arrow
TÜ99

β2-microglobulin is the 12 kDa β chain which noncovalently associates with the 44 kDa α chain to form the HLA Class I antigen complex. This antibody reacts with free or complexed β2-microglobulin. TÜ99 does not react with β2-microglobulin of other species. This antibody is suitable for staining formalin-fixed, paraffin-embedded tissue sections using TUF pretreatment.

551337 Rev. 6
フォーマットの詳細
Down Arrow Up Arrow
PE
R-Phycoerythrin (PE), is part of the BD family of Phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 496 nm and 566 nm and an emission maximum (Em Max) at 576 nm. PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 575/26-nm bandpass filter). As PE is excited by multiple lasers, this can result in cross-laser excitation and fluorescence spillover on instruments with various combinations of Blue, Green, and Yellow-Green lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
576 nm
551337 Rev.6
引用&参考文献
Down Arrow Up Arrow

Development References (3)

  1. Barclay NA, Brown MH, Birkeland ML, et al, ed. The Leukocyte Antigen FactsBook. San Diego, CA: Academic Press; 1997.
  2. Desoye G, Dohr GA, Motter W, et al. Lack of HLA class I and class II antigens on human preimplantation embryos. J Immunol. 1988; 140(12):4157-4159. (Biology). View Reference
  3. Dohr GA, Motter W, Leitinger S, et al. Lack of expression of HLA [corrected] class I and class II molecules on the human oocyte. J Immunol. 1987; 138(11):3766-3770. (Biology). View Reference
551337 Rev. 6

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.