BD Pharmingen™ FITC Mouse Anti-Human Blood Group A
クローン NaM87-1F6 (RUO)
Flow cytometric analysis of Human Blood Group A expression on human red blood cells. Human red blood cells were stained with either FITC Mouse IgG3, κ Isotype Control (Cat. No. 555578; dashed line histogram) or PE Mouse Anti-Human Blood Group A antibody (Cat. No. 550807; solid line histogram). The fluorescence histogram showing Human Blood Group A expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of erythrocytes.
Flow cytometric analysis of Human Blood Group A expression on human red blood cells. Human red blood cells were stained with either FITC Mouse IgG3, κ Isotype Control (Cat. No. 555578; dashed line histogram) or PE Mouse Anti-Human Blood Group A antibody (Cat. No. 550807; solid line histogram). The fluorescence histogram showing Human Blood Group A expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of erythrocytes.
Flow cytometric analysis of Human Blood Group A expression on human red blood cells. Human red blood cells were stained with either FITC Mouse IgG3, κ Isotype Control (Cat. No. 555578; dashed line histogram) or PE Mouse Anti-Human Blood Group A antibody (Cat. No. 550807; solid line histogram). The fluorescence histogram showing Human Blood Group A expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of erythrocytes.
Regulatory Statusの凡例
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Preparation and Storage
Product Notices
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- An isotype control should be used at the same concentration as the antibody of interest.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
関連製品
The NaM87-1F6 monoclonal antibody specifically binds to blood group A expressed on human erythrocytes. Clone NaM87-1F6 induces agglutination of human group A red blood cells. It does not react with human group B, or group O red blood cells.
Development References (3)
-
Blanchard D, Bruneau V, Bernard D, et al. Flow cytometry analysis of dual red blood cell populations after bone marrow transplantation. Br J Haematol. 1995; 89(4):741-747. (Clone-specific: Flow cytometry). View Reference
-
David B, Bernard D, Navenot JM, Muller JY, Blanchard D. Flow cytometric monitoring of red blood cell chimerism after bone marrow transplantation. Transfus Med. 1999; 9(3):209-217. (Clone-specific: Flow cytometry).
-
Walker RH, ed. Technical Manual of the American Association of Blood Banks. Arlington VA: 1990.
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.