Skip to main content Skip to navigation
BV650 Streptavidin
BV650 Streptavidin
Flow cytometric analysis of CD45R/B220 expression on mouse splenocytes.  Mouse splenic leucocytes were stained with Biotin Rat Anti-Mouse CD45R/B220 antibody (Cat. No. 553085/553086) followed by BD Horizon™ BV650 Streptavidin (Cat. No. 563855; solid line histogram) or with BD Horizon™ BV650 Streptavidin alone (dashed line histogram). Flow cytometric histograms were derived from gated events with the forward and side light-scatter characteristics of viable splenic leucocytes. Flow cytometric analysis was performed using a BD™ LSR II Flow Cytometer System.
Flow cytometric analysis of CD45R/B220 expression on mouse splenocytes.  Mouse splenic leucocytes were stained with Biotin Rat Anti-Mouse CD45R/B220 antibody (Cat. No. 553085/553086) followed by BD Horizon™ BV650 Streptavidin (Cat. No. 563855; solid line histogram) or with BD Horizon™ BV650 Streptavidin alone (dashed line histogram). Flow cytometric histograms were derived from gated events with the forward and side light-scatter characteristics of viable splenic leucocytes. Flow cytometric analysis was performed using a BD™ LSR II Flow Cytometer System.
Product Details
Down Arrow Up Arrow


BD Horizon™
Flow cytometry (Routinely Tested)
0.1 mg/ml
AB_2869528
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. Streptavidin was conjugated with dye under optimum conditions, and unconjugated Streptavidin and free dye were removed

Recommended Assay Procedures

BD Horizon™ BV650 Streptavidin is a useful second-step reagent for the indirect immunofluorescent staining of cells in combination with biotinylated primary antibodies for flow cytometric analysis.

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes are used in the same experiment.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions.  More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  3. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  4. Alexa Fluor® is a registered trademark of Molecular Probes, Inc., Eugene, OR.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  7. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  8. BD Horizon Brilliant Violet 650 is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,227,187; 8,455,613; 8,575,303; 8,354,239.
  9. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
563855 Rev. 4
Antibody Details
Down Arrow Up Arrow

Streptavidin is a non-glycosylated protein that is prepared chromatographically from the bacterium Streptomyces avidinii. Streptavidin homotetramers have a particularly high, non-covalent binding affinity for biotin. When conjugated with fluorochromes, streptavidin has been widely used with biotin-conjugated antibodies and other biotinylated specific-binding molecules (eg, recombinant proteins and lectins) to stain cells and tissues for subsequent multiparameter analysis by flow cytometry, fluorescence microscopy and imaging. Likewise, when conjugated with an enzyme (eg, Horseradish Peroxidase or Alkaline Phosphatase) and coupled with a colorimetric or luminescent substrate development system, streptavidin has found widespread use along with biotinylated antibodies in a number of applications including Western blot, ELISA, ELISPOT, immunocytochemistry and immunohistochemistry.

Streptavidin was conjugated to BD Horizon BV650 which is part of the BD Horizon Brilliant™ Violet family of dyes. This dye is a tandem fluorochrome of BD Horizon BV421 with an Ex Max of 405-nm and an acceptor dye with an Em Max at 650-nm.  BD Horizon BV650 can be excited by the violet laser and detected in a filter used to detect APC-like dyes (eg, 660/20-nm filter).  Due to the excitation and emission characteristics of the acceptor dye, there will be  spillover into the APC and Alexa Fluor® 700 detectors.  However, the spillover can be corrected through compensation as with any other dye combination.

563855 Rev. 4
Format Details
Down Arrow Up Arrow
BV650
The BD Horizon Brilliant Violet™ 650 (BV650) Dye is part of the BD Horizon Brilliant Violet™ family of dyes. This tandem fluorochrome is comprised of a BV421 donor with an excitation maximum (Ex Max) of 406-nm and an acceptor dye with an emission maximum (Em Max) at 649-nm. BV650, driven by BD innovation, is designed to be excited by the violet laser (405-nm) and detected using an optical filter centered near 650-nm (e.g., a 660/20-nm bandpass filter). The acceptor dye can be excited by the Red (628–640-nm) laser resulting in cross-laser excitation and fluorescence spillover. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BV650
Violet 405 nm
406 nm
649 nm
563855 Rev.4
Citations & References
Down Arrow Up Arrow

Development References (2)

  1. Diamandis EP, Christopoulos TK. The biotin-(strept)avidin system: principles and applications in biotechnology. Clin Chem. 1991; 37(5):625-636. (Biology). View Reference
  2. Shapiro HM. Practical flow cytometry, 4th ed.. Hoboken, N.J.: Wiley-Liss; 2003:1-681.
563855 Rev. 4

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.