Skip to main content Skip to navigation
Oligo Mouse Anti-Human CD134

BD™ AbSeq Oligo Mouse Anti-Human CD134

Clone L106

(RUO)
Product Details
Down Arrow Up Arrow


BD™ AbSeq
OX40; OX 40; OX40L Receptor; TNFRSF4; ACT35; TXGP1L; OX40L Receptor; IMD16
7293
2 µl
Mouse BALB/c IgG1, κ
Human (Tested in Development)
Single Cell 3' Sequencing (Qualified)
GTTATTTATCCCATGCGTTGCGAGAGAGTATTAGGC
AHS0271
Phytohemagglutinin-activated T lymphocytes
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO
Mouse


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography and conjugated to BD® AbSeq oligonucleotide under optimal conditions.

Recommended Assay Procedures

Put all BD® AbSeq Reagents to be pooled into a Latch Rack for 500 µL Tubes (Thermo Fisher Scientific Cat. No. 4900). Arrange the tubes so that they can be easily uncapped and re-capped with an 8-Channel Screw Cap Tube Capper (Thermo Fisher Scientific Cat. No. 4105MAT) and the reagents aliquoted with a multi-channel pipette.

BD® AbSeq tubes should be centrifuged for ≥ 30 seconds at 400 × g to ensure removal of any content in the cap/tube threads prior to the first opening.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended volume per test. Typical use is 2 µl for 1 × 10^6 cells in a 200-µl staining reaction.
  2. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  5. Illumina is a trademark of Illumina, Inc.
  6. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  7. Please refer to bd.com/genomics-resources for technical protocols.
  8. For U.S. patents that may apply, see bd.com/patents.
940392 Rev. 2
Antibody Details
Down Arrow Up Arrow
L106

The L106 monoclonal antibody specifically recognizes CD134 which is also known as OX40, OX40L receptor or TAX transcriptionally-activated glycoprotein 1 receptor (TXGP1L). CD134 is a ~48 kDa type I transmembrane glycoprotein that is encoded by TNFRSF4 (TNF receptor superfamily member 4) and belongs to the TNF/NGF receptor family. By sequence analysis, CD134 is related to the antigen recognized by the rat monoclonal antibody Ox 40. The CD134 antigen (Human Ox 40) is found on activated peripheral CD4+ T lymphocytes and a subset of activated CD8+ T lymphocytes. It is not expressed on CD3-activated purified CD8+ T lymphocytes. It is also present on HUT-102, an HTLV- 1-infected T-lymphocyte line. Its ligand, gp34 (CD252 or Ox 40 Ligand encoded by TNFSF4), is found on some antigen presenting cells including B cells and dendritic cells as well as Epstein Barr virus (EBV)-transformed B lymphocytes. Preliminary evidence suggests a possible role for CD134 antigen in graft rejection.

940392 Rev. 2
Format Details
Down Arrow Up Arrow
Antibody-Oligo
The antibody was conjugated to an oligonucleotide that contains an antibody clone-specific barcode (ABC) flanked by a poly-A tail on the 3' end and a PCR handle (PCR primer binding site) on the 5' end. The ABC for this antibody was designed to be used with other BD® AbSeq oligonucleotides conjugated to other antibodies. All AbSeq ABC sequences were selected in silico to be unique from human and mouse genomes, have low predicted secondary structure, and have high Hamming distance within the BD® AbSeq portfolio, to allow for sequencing error correction and unique mapping. The poly-A tail of the oligonucleotide allows the ABC to be captured by the BD Rhapsody™ system. The 5' PCR handle allows for efficient sequencing library generation for Illumina sequencing platforms.NOTE: The BD Rhapsody™ Single-Cell Analysis System must be used with the BD Rhapsody™ Express Instrument.
Antibody-Oligo
940392 Rev.2
Citations & References
Down Arrow Up Arrow

Development References (5)

  1. Godfrey W, Buck D, Harara M, Benike C, Engleman E. Studies of the L106 protein and its gene: Evidence that L106 and Ox 40 are homologous. In: Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995:1157-1160.
  2. Godfrey WR, Fagnoni FF, Harara MA, Buck D, Engleman EG. Identification of a human OX-40 ligand, a costimulator of CD4+ T cells with homology to tumor necrosis factor. J Exp Med. 1994 August; 180(2):757-762. (Clone-specific: Flow cytometry). View Reference
  3. Lamb LS, Abhyankar SA, Hazlett L, et al. Expression of CD134 (0X-40) on T cells during the first 100 days following allogeneic bone marrow transplantation as a marker for lymphocyte activation and therapy-resistant graft-versus-host disease.. Cytometry. 1999; 38(5):238-43. (Biology). View Reference
  4. Mallett S, Fossum S, Barclay AN. Characterization of the MRC OX40 antigen of activated CD4 positive T lymphocytes--a molecule related to nerve growth factor receptor. EMBO J. 1990; 9(4):1063-1068. (Biology). View Reference
  5. Paterson DJ, Jefferies WA, Green JR. Antigens of activated rat T lymphocytes including a molecule of 50,000 Mr detected only on CD4 positive T blasts. Mol Immunol. 1987; 24(12):1281-1290. (Biology). View Reference
940392 Rev. 2

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.