Skip to main content Skip to navigation
R718 Armenian Hamster Anti-ICOS (CD278)
R718 Armenian Hamster Anti-ICOS (CD278)
Analysis of ICOS (CD278) Expression      Left Panel - Two-color flow cytometric analysis of ICOS (CD278) expression on human peripheral blood lymphocytes. Whole blood was stained with FITC Mouse Anti-Human CD3 antibody (Cat. No. 561806/561807/555332) and either no antibody (BD Horizon™ R718 Autofluorescence Control; Top Plot) or BD Horizon™ R718 Hamster Anti-ICOS (CD278) antibody (Cat. No. 566990/566991; Bottom Plot). Erythrocytes were lysed with BD FACS Lysing Solution (Cat. No. 349202). Two-color flow cytometric contour plots showing the correlated expression of ICOS (CD278) [or BD Horizon™ R718 Autofluorescence] versus CD3 were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes.      Right Panel - Multicolor flow cytometric analysis of ICOS (CD278) expression on mouse thymocytes. Mouse thymocytes were preincubated with Purified Rat Anti-Mouse CD16/CD32 antibody (Mouse BD Fc Block™) (Cat. No. 553141/553142). The cells were then stained with FITC Rat Anti-Mouse CD4 (Cat. No. 553046/553047/561835) and PE Rat Anti-Mouse CD8a (Cat. No. 553033/553032/561095) antibodies, and either no antibody (BD Horizon™ R718 Autofluorescence Control; dashed line histograms) or BD Horizon™ R718 Hamster Anti-ICOS (CD278) antibody (solid line histograms) at 0.125 µg/test. The fluorescence histograms showing ICOS (CD278) expression (or BD Horizon™ R718 Autofluorescence) were derived from CD4 and CD8 gated events with the forward and side light-scatter characteristics of viable thymocytes as indicated. Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
Analysis of ICOS (CD278) Expression      Left Panel - Two-color flow cytometric analysis of ICOS (CD278) expression on human peripheral blood lymphocytes. Whole blood was stained with FITC Mouse Anti-Human CD3 antibody (Cat. No. 561806/561807/555332) and either no antibody (BD Horizon™ R718 Autofluorescence Control; Top Plot) or BD Horizon™ R718 Hamster Anti-ICOS (CD278) antibody (Cat. No. 566990/566991; Bottom Plot). Erythrocytes were lysed with BD FACS Lysing Solution (Cat. No. 349202). Two-color flow cytometric contour plots showing the correlated expression of ICOS (CD278) [or BD Horizon™ R718 Autofluorescence] versus CD3 were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes.      Right Panel - Multicolor flow cytometric analysis of ICOS (CD278) expression on mouse thymocytes. Mouse thymocytes were preincubated with Purified Rat Anti-Mouse CD16/CD32 antibody (Mouse BD Fc Block™) (Cat. No. 553141/553142). The cells were then stained with FITC Rat Anti-Mouse CD4 (Cat. No. 553046/553047/561835) and PE Rat Anti-Mouse CD8a (Cat. No. 553033/553032/561095) antibodies, and either no antibody (BD Horizon™ R718 Autofluorescence Control; dashed line histograms) or BD Horizon™ R718 Hamster Anti-ICOS (CD278) antibody (solid line histograms) at 0.125 µg/test. The fluorescence histograms showing ICOS (CD278) expression (or BD Horizon™ R718 Autofluorescence) were derived from CD4 and CD8 gated events with the forward and side light-scatter characteristics of viable thymocytes as indicated. Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
Product Details
Down Arrow Up Arrow


BD Horizon™
ICOS; AILIM; H4; Inducible T-cell costimulator; CVID1; Ly115
Human (QC Testing), Mouse (Tested in Development)
Armenian Hamster IgG
Mouse D10.G4.1 T-cell clone
Flow cytometry (Routinely Tested)
0.2 mg/ml
AB_2869993
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unreacted dye was removed.

Recommended Assay Procedures

  BD™ CompBeads can be used as surrogates to assess fluorescence spillover (Compensation). When fluorochrome conjugated antibodies are bound to BD CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD CompBead to ensure that BD CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. Alexa Fluor® is a registered trademark of Life Technologies Corporation.
  5. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  6. Species cross-reactivity detected in product development may not have been confirmed on every format and/or application.
  7. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  8. This product is provided under an Agreement between BIOTIUM and BD Biosciences. This product, and only in the amount purchased by buyer, may be used solely for buyer’s own internal research, in a manner consistent with the accompanying product literature. No other right to use, sell or otherwise transfer (a) this product, or (b) its components is hereby granted expressly, by implication or by estoppel. This product is for research use only. Diagnostic uses require a separate license from Biotium, Inc. For information on purchasing a license to this product including for purposes other than research, contact Biotium, Inc., 3159 Corporate Place, Hayward, CA 94545, Tel: (510) 265-1027. Fax: (510) 265-1352. Email: btinfo@biotium.com.
Antibody Details
Down Arrow Up Arrow
C398.4A

The C398.4A monoclonal antibody specifically binds to Inducible Costimulator (ICOS), which is also known as, CD278, Activation-inducible lymphocyte immunomediatory molecule (AILIM), or H4. ICOS is a type I transmembrane glycoprotein that forms a disulfide-linked homodimer and belongs to the CD28 family within the Ig superfamily. ICOS is expressed on either CD4+ or CD8+ single-positive mature thymocytes, T cells, or subsets of Innate Lymphoid Cells (ILC). Its expression is upregulated on activated T lymphocytes. ICOS is a costimulatory receptor that can bind to the B7-H2 ligand (CD275, ICOS-L) that is expressed on B cells, monocytes, macrophages, dendritic cells, and endothelial cells. ICOS plays a critical role in many types of T cell-dependent immunity. In the case of humoral immunity, for example, ICOS signaling is critical for the differentiation of T follicular helper (Tfh) cells and development of germinal centers. Although C398.4A was generated against mouse ICOS, this antibody reportedly crossreacts with human, rhesus, and rat ICOS.

  The antibody was conjugated to BD Horizon Red 718, which has been developed exclusively for BD Biosciences as a better alternative to Alexa Fluor® 700. BD Horizon Red 718 can be excited by the red laser (628 – 640 nm) and, with an Em Max around 718 nm, it can be detected using a 730/45 nm filter. Due to similar excitation and emission properties, we do not recommend using R718 in combination with APC-R700 or Alexa Fluor® 700.

Format Details
Down Arrow Up Arrow
R718
The BD Horizon™ Red 718 (R718) Dye is part of the BD red family of dyes. It is a small organic fluorochrome with an excitation maximum (Ex Max) at 695-nm and an emission maximum (Em Max) at 718-nm. Driven by BD innovation, R718 is designed to be excited by the red laser (627–640-nm) and detected using an optical filter centered near 720-nm (e.g., a 720/40-nm bandpass filter). R718 is a brighter alternative to Alexa Fluor™ 700. R718 is also a bright small molecule alternative to APC-R700 with lower spread into the APC detector. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
R718
Red 627-640 nm
695 nm
718 nm
Citations & References
Down Arrow Up Arrow

Development References (8)

  1. Araujo LM, Fert I, Jouhault Q, et al. Increased production of interleukin-17 over interleukin-10 by treg cells implicates inducible costimulator molecule in experimental spondyloarthritis. Arthritis Rheum. 2014; 66(9):2412-2422. (Clone-specific: Flow cytometry). View Reference
  2. Brenchley JM, Vinton C, Tabb B, et al. Differential infection patterns of CD4+ T cells and lymphoid tissue viral burden distinguish progressive and nonprogressive lentiviral infections.. Blood. 2012; 120(20):4172-81. (Clone-specific: Flow cytometry). View Reference
  3. Buonfiglio D, Bragardo M, Bonissoni S, et al. Characterization of a novel human surface molecule selectively expressed by mature thymocytes, activated T cells and subsets of T cell lymphomas. Eur J Immunol. 1999; 29(9):2863-2879. (Clone-specific: Flow cytometry, Immunohistochemistry, Immunoprecipitation, Radioimmunoassay). View Reference
  4. Buonfiglio D, Bragardo M, Redoglia V, et al. The T cell activation molecule H4 and the CD28-like molecule ICOS are identical. Eur J Immunol. 2000; 30(12):3463-3467. (Clone-specific: Blocking, Flow cytometry). View Reference
  5. Chen Y, Shen S, Gorentla BK, Gao J, Zhong XP. Murine regulatory T cells contain hyperproliferative and death-prone subsets with differential ICOS expression. J Immunol. 2012; 188(4):1698-1707. (Clone-specific: Flow cytometry, Fluorescence activated cell sorting). View Reference
  6. Klatt NR, Vinton CL, Lynch RM et al. SIV infection of rhesus macaques results in dysfunctional T- and B-cell responses to neo and recall Leishmania major vaccination. Blood. 2011; 118(22):5803-5812. (Clone-specific: Flow cytometry). View Reference
  7. Redoglia V, Dianzani U, Rojo JM, et al. Characterization of H4: a mouse T lymphocyte activation molecule functionally associated with the CD3/T cell receptor. Eur J Immunol. 1996; 26(11):2781-2789. (Immunogen: Bioassay, (Co)-stimulation, Flow cytometry, Functional assay, Immunoprecipitation, Radioimmunoassay). View Reference
  8. Xu H, Wang X, Lackner AA, Veazey RS. PD-1(HIGH) Follicular CD4 T Helper Cell Subsets Residing in Lymph Node Germinal Centers Correlate with B Cell Maturation and IgG Production in Rhesus Macaques. Front Biosci. 2014; 5(85):1-7. (Clone-specific: Flow cytometry). View Reference
View All (8) View Less

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.