Skip to main content Skip to navigation
BV711 Mouse Anti-Human TIGIT
Alert icon
Try the new and improved Anti-Human TIGIT antibody: [570379]
Product Details
Down Arrow Up Arrow


BD OptiBuild™
TIGIT; T-cell immunoreceptor with Ig and ITIM domains; VSIG9; VSTM3; WUCAM
Human (Tested in Development)
Mouse IgG2b, κ
Human TIGIT Recombinant Protein
Flow cytometry (Qualified)
0.2 mg/ml
201633
AB_2872302
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with BD Horizon BV711 under optimal conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes (including BD OptiBuild Brilliant reagents) are used in the same experiment.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions.  More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794).

Product Notices

  1. This antibody was developed for use in flow cytometry.
  2. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  3. Researchers should determine the optimal concentration of this reagent for their individual applications.
  4. An isotype control should be used at the same concentration as the antibody of interest.
  5. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  8. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  9. BD Horizon Brilliant Violet 711 is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,227,187; 8,455,613; 8,575,303; 8,354,239.
  10. Cy is a trademark of GE Healthcare.
  11. Alexa Fluor® is a registered trademark of Life Technologies Corporation.
747839 Rev. 1
Antibody Details
Down Arrow Up Arrow
741182

The 741182 monoclonal antibody specifically recognizes TIGIT (T cell Immunoreceptor with Ig and ITIM domains) which is also known as Vstm3 (V-set and transmembrane domain-containing 3), Vsig9 (V-set and Ig domain-containing 9) and WUCAM (Washington University Cell Adhesion Molecule). TIGIT is a 30-34 kDa single-pass type I transmembrane glycoprotein that belongs to the CD28 family within the Ig superfamily. TIGIT has an extracellular region with a V-type Ig-like domain, transmembrane sequence, and a cytoplasmic domain with an immunoreceptor tyrosine-based inhibitory motif (ITIM). TIGIT is expressed on NK cells and subsets of activated and memory T cells, regulatory T cells (Treg), and T follicular helper (Tfh) cells. TIGIT binds to CD112 (PVRL2/Nectin-2) and CD155 (PVR/Necl-5) that are expressed on dendritic cells (DC), endothelial cells, fibroblasts, and some tumor cells and can induce IL-10 release and inhibition of IL-12 production. Ligand-bound TIGIT downregulates TCR-mediated T cell activation and proliferation, and can block NK cell-mediated cytotoxicity.

The antibody was conjugated to BD Horizon™ BV711 which is part of the BD Horizon Brilliant™ Violet family of dyes. This dye is a tandem fluorochrome of BD Horizon BV421 with an Ex Max of 405-nm and an acceptor dye with an Em Max at 711-nm.  BD Horizon BV711 can be excited by the violet laser and detected in a filter used to detect Cy™5.5 / Alexa Fluor® 700-like dyes (eg, 712/20-nm filter).  Due to the excitation and emission characteristics of the acceptor dye, there may be moderate spillover into the Alexa Fluor® 700 and PerCP-Cy5.5 detectors.  However, the spillover can be corrected through compensation as with any other dye combination.

747839 Rev. 1
Format Details
Down Arrow Up Arrow
BV711
The BD Horizon Brilliant Violet™ 711 (BV711) Dye is part of the BD Horizon Brilliant Violet™ family of dyes. This tandem fluorochrome is comprised of a BV421 donor with an excitation maximum (Ex Max) of 407-nm and an acceptor dye with an emission maximum (Em Max) at 713-nm. BV711, driven by BD innovation, is designed to be excited by the violet laser (405-nm) and detected using an optical filter centered near 710-nm (e.g., a 712/20-nm bandpass filter). The acceptor dye can be excited by the Red (628–640-nm) laser resulting in cross-laser excitation and fluorescence spillover. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BV711
Violet 405 nm
407 nm
713 nm
747839 Rev.1
Citations & References
Down Arrow Up Arrow

Development References (3)

  1. Downs-Canner S, Berkey S, Delgoffe GM, et al. Suppressive IL-17A(+)Foxp3(+) and ex-Th17 IL-17A(neg)Foxp3(+) Treg cells are a source of tumour-associated Treg cells.. Nat Commun. 2017; 8:14649. (Clone-specific: Flow cytometry). View Reference
  2. Yasuma K, Yasunaga J, Takemoto K, et al. HTLV-1 bZIP Factor Impairs Anti-viral Immunity by Inducing Co-inhibitory Molecule, T Cell Immunoglobulin and ITIM Domain (TIGIT).. PLoS Pathog. 2016; 12(1):e1005372. (Clone-specific: Flow cytometry). View Reference
  3. Yu X, Harden K, Gonzalez LC, Francesco M, et al. The surface protein TIGIT suppresses T cell activation by promoting the generation of mature immunoregulatory dendritic cells. Nat Immunol. 2009; 10(1):48-57. (Biology). View Reference
747839 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described