Skip to main content Skip to navigation
PerCP-Cy™5.5 Rat Anti-Mouse Ly-6C
Alert icon
Consider BD Horizon RealBlue™ 705 (RB705) Reagents, a bright and clean fluorochrome alternative to BD Horizon™ BB700 and PerCP-Cy5.5 More Info #
PerCP-Cy™5.5 Rat Anti-Mouse Ly-6C
Flow cytometric analysis of Ly-6C on mouse splenocytes.  Splenocytes from BALB/c mice were stained either with a PerCP-Cy™5.5 Rat IgM, κ isotype control (shaded) or with the PerCP-Cy™5.5 Rat Anti-Mouse Ly-6C  antibody (unshaded).  Histograms were derived from gated events based on light scattering characteristics for splenocytes.  Flow cytometry was performed on a BD™ LSR II flow cytometry system.
PerCP-Cy™5.5 Rat Anti-Mouse Ly-6C
Flow cytometric analysis of Ly-6C on mouse splenocytes.  Splenocytes from BALB/c mice were stained with the PerCP-Cy™5.5 Rat Anti-Mouse Ly-6C  antibody in conjunction with a FITC Rat Anti-Mouse CD8a antibody.  Dot plots were derived from gated events based on light scattering characteristics for splenocytes.  Flow cytometry was performed on a BD™ LSR II flow cytometry system.
Flow cytometric analysis of Ly-6C on mouse splenocytes.  Splenocytes from BALB/c mice were stained either with a PerCP-Cy™5.5 Rat IgM, κ isotype control (shaded) or with the PerCP-Cy™5.5 Rat Anti-Mouse Ly-6C  antibody (unshaded).  Histograms were derived from gated events based on light scattering characteristics for splenocytes.  Flow cytometry was performed on a BD™ LSR II flow cytometry system.
Flow cytometric analysis of Ly-6C on mouse splenocytes.  Splenocytes from BALB/c mice were stained with the PerCP-Cy™5.5 Rat Anti-Mouse Ly-6C  antibody in conjunction with a FITC Rat Anti-Mouse CD8a antibody.  Dot plots were derived from gated events based on light scattering characteristics for splenocytes.  Flow cytometry was performed on a BD™ LSR II flow cytometry system.
Product Details
Down Arrow Up Arrow


BD Pharmingen™
Mouse (QC Testing)
Rat IgM, κ
Not reported
Flow cytometry (Routinely Tested)
0.2 mg/ml
AB_1727558
Aqueous buffered solution containing protein stabilizer and ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with PerCP-Cy5.5 under optimum conditions, and unconjugated antibody and free PerCP-Cy5.5 were removed. Storage of PerCP-Cy5.5 conjugates in unoptimized diluent is not recommended and may result in loss of signal intensity.

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Please observe the following precautions: Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
  4. Cy is a trademark of Amersham Biosciences Limited. This conjugated product is sold under license to the following patents: US Patent Nos. 5,486,616; 5,569,587; 5,569,766; 5,627,027.
  5. This product is subject to proprietary rights of Amersham Biosciences Corp. and Carnegie Mellon University and made and sold under license from Amersham Biosciences Corp. This product is licensed for sale only for research. It is not licensed for any other use. If you require a commercial license to use this product and do not have one return this material, unopened to BD Biosciences, 10975 Torreyana Rd, San Diego, CA 92121 and any money paid for the material will be refunded.
  6. PerCP-Cy5.5 is optimized for use with a single argon ion laser emitting 488-nm light. Because of the broad absorption spectrum of the tandem fluorochrome, extra care must be taken when using dual-laser cytometers, which may directly excite both PerCP and Cy5.5™. We recommend the use of cross-beam compensation during data acquisition or software compensation during data analysis.
  7. PerCP-Cy5.5–labelled antibodies can be used with FITC- and R-PE–labelled reagents in single-laser flow cytometers with no significant spectral overlap of PerCP-Cy5.5, FITC, and R-PE fluorescence.
  8. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  9. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  10. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
560525 Rev. 1
Antibody Details
Down Arrow Up Arrow
AL-21

The AL-21 monoclonal antibody specifically binds to a non-polymorphic determinant of Ly-6C, a 14-17 kDa GPI-linked cell-surface antigen found on some monocyte/macrophage populations, granulocytes, endothelial cells, plasma cells, and thymocyte, NK-cell, and T-subsets.  Mice with the Ly-6.2 alloantigen (eg, AKR, C57BL, C57BR, C57L, C58, DBA/2, PL, SJL, SWR, 129) have subsets of CD8+ and CD4+ Ly-6C+ T cells, while Ly-6.1 strains (eg, A, BALB/c, CBA, C3H/He, DBA/1, NZB) have only CD8+ Ly-6C+ T cells.   Upregulation of Ly-6C expression on CD8+ T cells by interferons α and β and poly (I:C) has been described,  and Ly-6C is a memory marker on CD8+ T cells.

560525 Rev. 1
Format Details
Down Arrow Up Arrow
PerCP-Cy5.5
PerCP-Cy5.5 dye is part of the BD blue family of dyes. This tandem fluorochrome is comprised of a fluorescent protein complex (PerCP) with an excitation maximum (Ex Max) of 482 nm and an acceptor dye with an emission maximum (Em Max) at 676 nm. PerCP-Cy5 is designed to be excited by the blue laser (488-nm) and detected using an optical filter centered near 680 nm (e.g., a 695/40 nm bandpass filter). The donor dye can be partially excited by the Violet (405-nm) laser resulting in cross-laser excitation and fluorescence spillover. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PerCP-Cy5.5
Blue 488 nm
482 nm
676 nm
560525 Rev.1
Citations & References
Down Arrow Up Arrow

Development References (7)

  1. Cerwenka A, Carter LL, Reome JB, Swain SL, Dutton RW. In vivo persistence of CD8 polarized T cell subsets producing type 1 or type 2 cytokines. J Immunol. 1998; 161(1):97-105. (Biology). View Reference
  2. Jutila DB, Kurk S, Jutila MA.. Differences in the expression of Ly-6C on neutrophils and monocytes following PI-PLC hydrolysis and cellular activation.. Immunol Lett. 1994 ; 41(1):49-57. (Biology). View Reference
  3. Jutila MA, Kroese FG, Jutila KL, et al. Ly-6C is a monocyte/macrophage and endothelial cell differentiation antigen regulated by interferon-gamma. Eur J Immunol. 1988; 18(11):1819-1826. (Biology). View Reference
  4. Sato N, Yahata T, Santa K. Functional characterization of NK1.1 + Ly-6C+ cells. Immunol Lett. 1996; 1(54):1-5-9. (Biology). View Reference
  5. Takahama Y, Sharrow SO, Singer A. Expression of an unusual T cell receptor (TCR)-V beta repertoire by Ly-6C+ subpopulations of CD4+ and/or CD8+ thymocytes. Evidence for a developmental relationship between Ly-6C+ thymocytes and CD4-CD8-TCR-alpha beta+ thymocytes. J Immunol. 1991; 147(9):2883-2891. (Biology). View Reference
  6. Tough DF, Borrow P, Sprent J. Induction of bystander T cell proliferation by viruses and type I interferon in vivo. Science. 1996; 272(5270):1947-1950. (Biology). View Reference
  7. Wrammert J, Källberg E, Agace WW, Leanderson T. Ly6C expression differentiates plasma cells from other B cell subsets in mice. Eur J Immunol. 2002; 32(1):97-103. (Biology). View Reference
View All (7) View Less
560525 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.