PE Mouse Anti-Human CD20
Alert icon
Consider BD Horizon RealYellow™ 586 (RY586) Reagents, a bright and clean fluorochrome alternative to PE off the yellow-green laser. RY586 can be used alongside PE on spectral cytometers. More Info #
Product Details
Down Arrow Up Arrow


BD Pharmingen™
Rhesus, Cynomolgus, Baboon (QC Testing)
Mouse C57BL/6 IgG2b, κ
Human 6.16c1.3 B cell line
Flow cytometry (Routinely Tested), Immunohistochemistry-frozen (Tested During Development)
20 µl
II B22; III B739, NL382; IV B201
931
AB_396502
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation And Storage

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with R-PE under optimum conditions, and unconjugated antibody and free PE were removed. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  3. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
556633 Rev. 6
Antibody Details
Down Arrow Up Arrow
2H7

Clone 2H7 reacts with the human form of a phosphoprotein, CD20, found on circulating peripheral blood B lymphocytes. This clone also cross-reacts with a subset of peripheral blood lymphocytes, but not monocytes nor granulocytes, of baboon and both rhesus and cynomolgus macaque monkeys. The distrubution on lymphocytes is similar to that seen with normal human donor lymphocytes, namely bright staining on B lymphocytes and weak reactivity on a small subset of CD3-positive T lymphocytes.

556633 Rev. 6
Format Details
Down Arrow Up Arrow
PE
R-Phycoerythrin (PE), is part of the BD family of Phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 496 nm and 566 nm and an emission maximum (Em Max) at 576 nm. PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 575/26-nm bandpass filter). As PE is excited by multiple lasers, this can result in cross-laser excitation and fluorescence spillover on instruments with various combinations of Blue, Green, and Yellow-Green lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
576 nm
556633 Rev.6
Citations & References
Down Arrow Up Arrow

Development References (3)

  1. Hultin LE, Hausner MA, Hultin PM, Giorgi JV. CD20 (pan-B cell) antigen is expressed at a low level on a subpopulation of human T lymphocytes. Cytometry. 1993; 14(2):193-204. (Biology). View Reference
  2. Knapp W. W. Knapp .. et al., ed. Leucocyte typing IV : white cell differentiation antigens. Oxford New York: Oxford University Press; 1989:1-1182.
  3. Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995.
556633 Rev. 6

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.