Skip to main content Skip to navigation
PE Rat Anti-Integrin β7
PE Rat Anti-Integrin β7
Flow cytometric analysis of Integrin β7 expression on human peripheral blood lymphocytes. Whole blood was stained with either PE Rat IgG2a, κ Isotype Control (Cat. No. 555844; dashed line histogram) or PE Rat Anti-Integrin β7 antibody (Cat. No. 555945; solid line histogram). Erythrocytes were lysed with BD FACS Lysing Solution (Cat. No. 349202). The fluorescence histograms were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometry was performed on a BD FACScan™ system.
Flow cytometric analysis of Integrin β7 expression on human peripheral blood lymphocytes. Whole blood was stained with either PE Rat IgG2a, κ Isotype Control (Cat. No. 555844; dashed line histogram) or PE Rat Anti-Integrin β7 antibody (Cat. No. 555945; solid line histogram). Erythrocytes were lysed with BD FACS Lysing Solution (Cat. No. 349202). The fluorescence histograms were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometry was performed on a BD FACScan™ system.
Product Details
Down Arrow Up Arrow


BD Pharmingen™
Itgb7; Integrin β7; Integrin beta 7; ITB7; Ly-69; Ly69
Human (QC Testing), Mouse (Tested in Development)
Rat F344, also known as Fischer, CDF IgG2a, κ
Mouse T lymphoma line TK1
Flow cytometry (Routinely Tested)
20 µl
VI A024, VI 6T-101
AB_396241
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with R-PE under optimum conditions, and unconjugated antibody and free PE were removed.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Species cross-reactivity detected in product development may not have been confirmed on every format and/or application.
  7. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
555945 Rev. 4
Antibody Details
Down Arrow Up Arrow
FIB504

The FIB504 monoclonal antibody specifically recognizes mouse integrin β7 subunit (130 kDa) but also crossreacts with human integrin β7. Integrin β7 associates with α4 (CD49d) expressed on subsets of lymphocytes and thymocytes. It also associates with αIEL (CD103) expressed on T cells adjacent to mucosal epithelium and intraepithelial lymphocytes. Integrin β7 plays an important role in the adhesion of leukocytes to endothelial cells promoting the transmigration of leucocytes to extravascular spaces during the inflammatory response.

555945 Rev. 4
Format Details
Down Arrow Up Arrow
PE
R-Phycoerythrin (PE), is part of the BD family of Phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 496 nm and 566 nm and an emission maximum (Em Max) at 576 nm. PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 575/26-nm bandpass filter). As PE is excited by multiple lasers, this can result in cross-laser excitation and fluorescence spillover on instruments with various combinations of Blue, Green, and Yellow-Green lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
576 nm
555945 Rev.4
Citations & References
Down Arrow Up Arrow

Development References (7)

  1. Andrew DP, Berlin C, Honda S, et al. Distinct but overlapping epitopes are involved in alpha 4 beta 7-mediated adhesion to vascular cell adhesion molecule-1, mucosal addressin-1, fibronectin, and lymphocyte aggregation. J Immunol. 1994; 153(9):3847-3861. (Biology). View Reference
  2. Berlin C, Berg EL, Briskin MJ, et al. Alpha 4 beta 7 integrin mediates lymphocyte binding to the mucosal vascular addressin MAdCAM-1. Cell. 1993; 74(1):185-195. (Biology). View Reference
  3. Butcher EC, Picker LJ. Lymphocyte homing and homeostasis. Science. 1996; 272(5258):60-66. (Biology). View Reference
  4. Erle DJ, Briskin MJ, Butcher EC, Garcia-Pardo A, Lazarovits AI, Tidswell M. Expression and function of the MAdCAM-1 receptor, integrin alpha 4 beta 7, on human leukocytes. J Immunol. 1994; 153(2):517-528. (Biology). View Reference
  5. Kishimoto T. Tadamitsu Kishimoto .. et al., ed. Leucocyte typing VI : white cell differentiation antigens : proceedings of the sixth international workshop and conference held in Kobe, Japan, 10-14 November 1996. New York: Garland Pub.; 1997.
  6. Rott LS, Briskin MJ, Andrew DP, Berg EL, Butcher EC. A fundamental subdivision of circulating lymphocytes defined by adhesion to mucosal addressin cell adhesion molecule-1. Comparison with vascular cell adhesion molecule-1 and correlation with beta 7 integrins and memory differentiation. J Immunol. 1996; 156(10):3727-3736. (Biology). View Reference
  7. Teague TK, Lazarovits AI, McIntyre BW. Integrin alpha 4 beta 7 co-stimulation of human peripheral blood T cell proliferation. Cell Adhes Commun. 1994; 2(6):539-547. (Biology). View Reference
View All (7) View Less
555945 Rev. 4

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.