-
Your selected country is
United States
- Change country/language
-
Reagents
- Flow Cytometry Reagents
-
Western Blotting and Molecular Reagents
- Immunoassay Reagents
-
Single-Cell Multiomics Reagents
- BD® OMICS-Guard Sample Preservation Buffer
- BD® AbSeq Assay
- BD® OMICS-One Immune Profiler Protein Panel
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Accessory Kits
-
Functional Assays
-
Microscopy and Imaging Reagents
-
Cell Preparation and Separation Reagents
-
- BD® OMICS-Guard Sample Preservation Buffer
- BD® AbSeq Assay
- BD® OMICS-One Immune Profiler Protein Panel
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Accessory Kits
- United States (English)
- Change country/language
Old Browser
This page has been recently translated and is available in French now.
Looks like you're visiting us from {countryName}.
Would you like to stay on the current country site or be switched to your country?
Multicolor flow cytometric analysis of TCR Vγ6 expression on newborn Mouse thymocytes. Two-day old BALB/c Mouse thymocytes were isolated and then stained with PE Hamster Anti-Mouse CD3e antibody (Cat. No. 553064), BD Horizon™ BV421 Hamster Anti-Mouse γδ T-Cell Receptor (TCR γδ; Cat. No. 562892), and with either BD Horizon™ RB705 Mouse IgG1, κ Isotype Control (Cat. No. 570261; Left Plot) or BD Horizon™ RB705 Mouse Anti-Mouse TCR Vγ6 antibody (Cat. No. 570931/571003; Right Plot) at 0.5 µg/test. BD Via-Probe™ Cell Viability 7-AAD Solution (Cat. No. 555815) was added to cells right before analysis. The bivariate pseudocolor density plot showing the correlated expression of TCR Vγ6 (or Ig Isotype control staining) versus TCR γδ was derived from gated events with the forward and side light-scatter characteristics of viable (7-AAD-negative) CD3e-positive lymphocytes. Flow cytometry and data analysis were performed using a BD FACSymphony™ A5 SE Cell Analyzer System and FlowJo™ Software. Data shown on this Technical Data Sheet are not lot specific.
BD Horizon™ RB705 Mouse Anti-Mouse TCR Vγ6
Regulatory Status Legend
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Preparation And Storage
Recommended Assay Procedures
BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.
Product Notices
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- An isotype control should be used at the same concentration as the antibody of interest.
- Please observe the following precautions: We recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to protect exposure of conjugated reagents, including cells stained with those reagents, to any room illumination. Absorption of visible light can significantly affect the emission spectra and quantum yield of tandem fluorochrome conjugates.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- When using high concentrations of antibody, background binding of this dye to erythroid fragments produced by ammonium chloride-based lysis, such as with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899), has been observed when the antibody conjugate was present during the lysis procedure. This may cause nonspecific staining of target cells, such as leukocytes, which have bound the resulting erythroid fragments. This background can be mitigated by any of the following: titrating the antibody conjugate to a lower concentration, fixing samples with formaldehyde, or removing erythrocytes before staining (eg, gradient centrifugation or pre-lysis with wash). This background has not been observed when cells were lysed with BD FACS™ Lysing Solution (Cat. No. 349202) after staining.
- Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
- Tandem fluorochromes contain both an energy donor and an energy acceptor. Although every effort is made to minimize the lot-to-lot variation in the efficiency of the fluorochrome energy transfer, differences in the residual emission from the donor may be observed. Additionally, multi-laser cytometers may directly excite both the donor and acceptor fluorochromes. Therefore, we recommend for every tandem conjugate, a matched individual single-stain control be acquired for generating a compensation or spectral unmixing matrix.
- Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.
- For U.S. patents that may apply, see bd.com/patents.
Companion Products
The 1C10-1F7 monoclonal antibody specifically recognizes the variable gamma 6 region of the γ subunit of the mouse γδ T cell receptor for antigen, TCR Vγ6 (using the Heilig and Tonegawa nomenclature for mouse TCR γ and δ chains). TCR Vγ6 is encoded by the Trgv6 (T cell receptor gamma, variable 6) gene element. TCR Vγ6 is expressed by a subset of TCR γδ+ thymocytes that appear from approximately embryonic day 15 to birth and express Vγ6 paired with Vδ1 γδ TCR. These invariant TCR Vγ6Vδ1+ T cells home to various tissues including the epithelia of the lungs, peritoneal cavity, uterus, testis, tongue as well as the dermis, lamina propria of the colon, and adipose tissue. They are are programmed to secrete IL-17 upon activation. The 1C10-1F7 antibody has been found useful for immunofluorescent staining and flow cytometric analysis of TCR Vγ6+ T cells from C57BL/6 and BALB/c mice. It was also found useful for immunohistochemical analysis and in vivo blocking studies of TCR Vγ6+ γδ T cell function as well. This antibody is suitable for TCR Vγ6+ thymocyte and γδ T cell separations and analyzing TCR Vγ repertoires expressed by thymocytes, peripheral T cells, and T cell hybridomas in developmental and other experimental model systems. TCR Vγ6 is referred to as TCR Vγ4 using the Garman, Doherty, and Raulet nomenclature for mouse TCR γ and δ chains.
Development References (4)
-
Hatano S, Tun X, Noguchi N, et al. Development of a new monoclonal antibody specific to mouse Vγ6 chain.. Life Sci Alliance. 2019; 2(3):e201900363. (Immunogen: Flow cytometry, Functional assay, Immunofluorescence, Immunohistochemistry, In vivo exacerbation). View Reference
-
Monin L, Ushakov DS, Arnesen H, et al. γδ T cells compose a developmentally regulated intrauterine population and protect against vaginal candidiasis.. Mucosal Immunol. 2020; 13(6):969-981. (Clone-specific: Flow cytometry). View Reference
-
Roark CL, Aydintug MK, Lewis J, et al. Subset-specific, uniform activation among V gamma 6/V delta 1+ gamma delta T cells elicited by inflammation.. J Leukoc Biol. 2004; 75(1):68-75. (Biology). View Reference
-
Tun X, Hatano S, Mine K, et al. Vγ6+ γδ T cells are critical for protection against infection by Escherichia coli in mice.. Eur J Immunol. 2021; 51(8):2093-2096. (Clone-specific: Flow cytometry). View Reference
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.