
-
Reagents
- Flow Cytometry Reagents
-
Western Blotting and Molecular Reagents
- Immunoassay Reagents
-
Single-Cell Multiomics Reagents
- BD® OMICS-Guard Sample Preservation Buffer
- BD® AbSeq Assay
- BD® OMICS-One Immune Profiler Protein Panel
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Accessory Kits
-
Functional Assays
-
Microscopy and Imaging Reagents
-
Cell Preparation and Separation Reagents
-
Promotions
-
BD Primer Program
-
BD Horizon™ Human T Cell Backbone Panel
-
New Lab Promotion
-
BD’s 50 Years of Innovation Research Instrument Promotion
-
BD FACSLyric™ Flow Cytometers 50th Anniversary Promo
-
BD FACSAria™ Customer Loyalty Promotion
-
FlowJo™ Software Promotion
-
BD® Research Cloud Promotion
-
35% off Research Reagents + Free Shipping!
-
BD Primer Program
-
- BD® OMICS-Guard Sample Preservation Buffer
- BD® AbSeq Assay
- BD® OMICS-One Immune Profiler Protein Panel
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Accessory Kits
- United States (English)
-
Change country/language
Old Browser
This page has been recently translated and is available in French now.
Looks like you're visiting us from {countryName}.
Would you like to stay on the current country site or be switched to your country?
BD Pharmingen™ Alexa Fluor™ 647 Rat Anti-Mouse CD169 (Siglec-1)
Clone 3D6/CD169 (also known as 3D6)
(RUO)



Multicolor flow cytometric analysis of CD169 (Siglec -1) expression on Mouse myeloid cells. C57BL/6 Mouse bone marrow cells were preincubated with Purified Rat Anti-Mouse CD16/CD32 antibody (Mouse BD Fc Block™) [Cat. No. 553141/553142]. The cells were then stained with BD Horizon™ BV421 Rat Anti-Mouse Ly-6G and Ly-6C antibody (Cat. No. 562709) and with either Alexa Fluor™ 647 Rat IgG2a, κ Isotype Control (Cat. No. 557690; Left Plot) or Alexa Fluor™ 647 Rat Anti-Mouse CD169 (Siglec-1) antibody (Cat. No. 570769/570847; Right Plot) at 1 µg/test. BD Via-Probe™ Cell Viability 7-AAD Solution (Cat. No. 555815/555816) was added to cells right before analysis. The bivariate pseudocolor density plot showing the correlated expression of CD169 (Siglec-1) [or Ig Isotype control staining] versus Ly-6G and Ly-6C was derived from gated events with the forward and side light-scatter characteristics of viable (7-AAD-negative) bone marrow cells. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Flow Cytometer System and FlowJo™ Software. Data shown on this Technical Data Sheet are not lot specific.


BD Pharmingen™ Alexa Fluor™ 647 Rat Anti-Mouse CD169 (Siglec-1)

Regulatory Status Legend
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Preparation And Storage
Recommended Assay Procedures
BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cell and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.
Product Notices
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- An isotype control should be used at the same concentration as the antibody of interest.
- Alexa Fluor® 647 fluorochrome emission is collected at the same instrument settings as for allophycocyanin (APC).
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- This product is provided under an intellectual property license between Life Technologies Corporation and BD Businesses. The purchase of this product conveys to the buyer the non-transferable right to use the purchased amount of the product and components of the product in research conducted by the buyer (whether the buyer is an academic or for-profit entity). The buyer cannot sell or otherwise transfer (a) this product (b) its components or (c) materials made using this product or its components to a third party or otherwise use this product or its components or materials made using this product or its components for Commercial Purposes. Commercial Purposes means any activity by a party for consideration and may include, but is not limited to: (1) use of the product or its components in manufacturing; (2) use of the product or its components to provide a service, information, or data; (3) use of the product or its components for therapeutic, diagnostic or prophylactic purposes; or (4) resale of the product or its components, whether or not such product or its components are resold for use in research. For information on purchasing a license to this product for any other use, contact Life Technologies Corporation, Cell Analysis Business Unit Business Development, 29851 Willow Creek Road, Eugene, OR 97402, USA, Tel: (541) 465-8300. Fax: (541) 335-0504.
- Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
- Alexa Fluor™ is a trademark of Life Technologies Corporation.
- For U.S. patents that may apply, see bd.com/patents.
Companion Products






The 3D6 monoclonal antibody specifically recognizes CD169 which is a ~185 kDa type I transmembrane glycoprotein that is encoded by Siglec1. CD169 belongs to the Sialic acid binding Ig like lectins (Siglec) family and is also known as Sialoadhesin (Sn), Siglec-1, or Sheep erythrocyte receptor (SER). CD169 is expressed on subsets of macrophages found in the bone marrow, secondary lymphoid tissues, liver colon and lungs. It binds to the oligosaccharide sequence NeuAc alpha 2,3Gal present on glycolipids and glycoproteins including CD43, CD162, CD206, or CD227. CD169 serves as an adhesion molecule that can mediate cellular interactions with the extracellular matrix or with other cells including lymphocytes and myeloid cells. CD169 may play a role in erythroid and myeloid cell development as well as leucocyte trafficking and inflammation.
Development References (4)
-
Crocker PR, Freeman S, Gordon S, Kelm S. Sialoadhesin binds preferentially to cells of the granulocytic lineage.. J Clin Invest. 1995; 95(2):635-43. (Immunogen: Blocking, Radioimmunoassay). View Reference
-
Ducreux J, Crocker PR, Vanbever R. Analysis of sialoadhesin expression on mouse alveolar macrophages.. Immunol Lett. 2009; 124(2):77-80. (Clone-specific: Blocking, Inhibition). View Reference
-
Kumamoto Y, Higashi N, Denda-Nagai K, et al. Identification of sialoadhesin as a dominant lymph node counter-receptor for mouse macrophage galactose-type C-type lectin 1.. J Biol Chem. 2004; 279(47):49274-80. (Clone-specific: Fluorescence microscopy, Immunofluorescence, Western blot). View Reference
-
Nath D, van der Merwe PA, Kelm S, Bradfield P, Crocker PR. The amino-terminal immunoglobulin-like domain of sialoadhesin contains the sialic acid binding site. Comparison with CD22.. J Biol Chem. 1995; 270(44):26184-91. (Clone-specific: Functional assay, Immunoaffinity chromatography). View Reference
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.