Skip to main content Skip to navigation
Biotin Mouse Anti-Human HLA-DR
Biotin Mouse Anti-Human HLA-DR
Multiparameter flow cytometric analysis of HLA-DR expression on human peripheral blood leucocyte populations. Whole blood was stained with either Biotin Mouse IgG2a, κ Isotype Control (Cat. No. 553455; Left Plot) or Biotin Mouse Anti-Human HLA-DR antibody (Cat. No. 567712; Right Plot) at 1 µg/test. The cells were counterstained with PE-Streptavidin (Cat. No. 554061). The erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202). The bivariate pseudocolor density plot showing the correlated expression of HLA-DR (or Ig Isotype control staining) versus side-light scatter (SSC-A) signals was derived from gated events with the forward and side light-scatter characteristics of intact leucocyte populations. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
Multiparameter flow cytometric analysis of HLA-DR expression on human peripheral blood leucocyte populations. Whole blood was stained with either Biotin Mouse IgG2a, κ Isotype Control (Cat. No. 553455; Left Plot) or Biotin Mouse Anti-Human HLA-DR antibody (Cat. No. 567712; Right Plot) at 1 µg/test. The cells were counterstained with PE-Streptavidin (Cat. No. 554061). The erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202). The bivariate pseudocolor density plot showing the correlated expression of HLA-DR (or Ig Isotype control staining) versus side-light scatter (SSC-A) signals was derived from gated events with the forward and side light-scatter characteristics of intact leucocyte populations. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
Product Details
Down Arrow Up Arrow


BD Pharmingen™
MHC class II antigen; HLA class II histocompatibility antigen
Human (QC Testing)
Mouse IgG2a, κ
Human lymphoblastoid B-cell line RPMI 8866
Flow cytometry (Routinely Tested)
0.5 mg/ml
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with biotin under optimum conditions, and unreacted biotin was removed.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  3. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  4. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  5. An isotype control should be used at the same concentration as the antibody of interest.
  6. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
567712 Rev. 1
Antibody Details
Down Arrow Up Arrow
L243

The L243 monoclonal antibody specifically binds to HLA-DR, a major histocompatibility complex (MHC) class II antigen. HLA-DR antigens are encoded by genes within the Human Leukocyte Antigen (HLA) Complex located on chromosome 6. HLA-DR is a transmembrane heterodimeric glycoprotein composed of an α chain (36 kDa) and a β subunit (27 kDa) expressed primarily on antigen presenting cells including B cells, dendritic cells, monocytes, macrophages, Langerhans cells, and thymic epithelial cells. HLA-DR is also expressed on activated T cells. This molecule plays a major role in mediating cellular interactions during antigen presentation to CD4-positive T cells.

567712 Rev. 1
Format Details
Down Arrow Up Arrow
Biotin
Biotin is a ubiquitous co-factor (also known as Vitamin B7) that has many properties that make it extremely useful for molecular biology. Biotin has an extremely high affinity for the Avidin family of proteins (Kd = 10-15 M), making it the perfect tool to link two molecules. Biotin labeled antibodies can be combined with any number of Avidin-conjugated probes in order to customize an assay to a particular need. This is especially useful in the case of magnetic cell separation using streptavidin/magnetic bead conjugates, or in the case of flow cytometry using streptavidin/fluorophore conjugates.
Biotin
567712 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "567712" on CiteAb

Development References (9)

  1. Autissier P, Soulas C, Burdo TH, Williams KC. Evaluation of a 12-color flow cytometry panel to study lymphocyte, monocyte, and dendritic cell subsets in humans.. Cytometry A. 2010; 77(5):410-9. (Clone-specific: Flow cytometry). View Reference
  2. Brodsky FM. A matrix approach to human class II histocompatibility antigens: reactions of four monoclonal antibodies with the products of nine haplotypes.. Immunogenetics. 1984; 19(3):179-94. (Clone-specific: Blocking, Immunoprecipitation, Radioimmunoassay). View Reference
  3. Charles N, Hardwick D, Daugas E, Illei GG, Rivera J. Basophils and the T helper 2 environment can promote the development of lupus nephritis.. Nat Med. 2010; 16(6):701-7. (Clone-specific: Flow cytometry). View Reference
  4. Engleman EG, Warnke R, Fox RI, Dilley J, Benike CJ, Levy R. Studies of a human T lymphocyte antigen recognized by a monoclonal antibody.. Proc Natl Acad Sci USA. 1981; 78(3):1791-5. (Clone-specific: Immunohistochemistry). View Reference
  5. Fujita H, Nograles KE, Kikuchi T, Gonzalez J, Carucci JA, Krueger JG. Human Langerhans cells induce distinct IL-22-producing CD4+ T cells lacking IL-17 production.. Proc Natl Acad Sci U S A. 2009; 106(51):21795-800. (Clone-specific: Flow cytometry). View Reference
  6. Lampson LA, Levy R. Two populations of Ia-like molecules on a human B cell line.. J Immunol. 1980; 125(1):293-9. (Immunogen: Blocking, Immunoprecipitation, Radioimmunoassay). View Reference
  7. Stumptner-Cuvelette P, Morchoisne S, Dugast M, et al. HIV-1 Nef impairs MHC class II antigen presentation and surface expression.. Proc Natl Acad Sci U S A. 2001; 98(21):12144-9. (Clone-specific: Flow cytometry). View Reference
  8. Tomkinson BE, Wagner DK, Nelson DL, Sullivan JL. Activated lymphocytes during acute Epstein-Barr virus infection.. J Immunol. 1987; 139(11):3802-7. (Clone-specific: Flow cytometry). View Reference
  9. Wang RF, Wang X, Atwood AC, Topalian SL, Rosenberg SA. Cloning genes encoding MHC class II-restricted antigens: mutated CDC27 as a tumor antigen.. Science. 1999; 284(5418):1351-4. (Clone-specific: Blocking). View Reference
View All (9) View Less
567712 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.