Skip to main content Skip to navigation
BB700 Mouse Anti-Human TCR Vβ11
Product Details
Down Arrow Up Arrow


BD OptiBuild™
TCR V beta 11; TCR Vbeta11; TCRBV11S1; TRBV251
Human (Tested in Development)
Mouse BALB/c IgG2a, κ
T Cell Clone
Flow cytometry (Qualified)
0.2 mg/ml
28582
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation).  When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells.   However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls.  It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

For optimal and reproducible results, BD Horizon Brilliant™ Stain Buffer should be used anytime BD Horizon Brilliant™ dyes are used in a multicolor flow cytometry panel.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. When BD Horizon Brilliant Stain Buffer is used in in the multicolor panel, it should also be used in the corresponding compensation controls for all dyes to achieve the most accurate compensation. For the most accurate compensation, compensation controls created with either cells or beads should be exposed to BD Horizon Brilliant Stain Buffer for the same length of time as the corresponding multicolor panel. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).

For optimal results, it is recommended to perform two washes after staining with antibodies. Cells may be prepared, stained with antibodies and washed twice with wash buffer per established protocols for immunofluorescent staining prior to acquisition on a flow cytometer. Performing fewer than the recommended wash steps may lead to increased spread of the negative population.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  3. For U.S. patents that may apply, see bd.com/patents.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  6. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  7. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  8. An isotype control should be used at the same concentration as the antibody of interest.
  9. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.
759614 Rev. 1
Antibody Details
Down Arrow Up Arrow
C21

The C21 monoclonal antibody specifically recognizes the variable beta 11 region of the β subunit of the human αβ T cell receptor for antigen (TCR Vβ11). TCR Vβ11 is encoded by TRBV25-1 (T cell receptor beta variable 25-1) which is also known as TCRBV11S1. TCR Vβ11 can pair with different TCR Vα region containing TCR α chains. The paired expression of semivariant TCR Vβ11 with invariant TCR Vα24 and Jα18  identifies some CD3+TCR αβ+ positive thymocytes and from ~ 0.01-0.92%  of peripheral blood CD3+ TCR αβ+ T cells known as invariant NKT (iNKT) cells or Type I NKT cells. iNKT cells can be divided into three subpopulations which are either CD4+, CD8+, or CD4-CD8- double negative. Due to their innate-like responsiveness, tissue resident iNKT cells are capable of rapid effector responses to microbial or self-lipid antigens presented by the cell surface MHC class Ib molecule, CD1d. iNKT cells recognize and respond to α-galactosylceramide (α-GalCer) and various self-lipids such as sphingolipids and diacylglycerols and microbial lipids presented by CD1d. iNKT cells can produce high levels of cytokines, including IL-4 and IFN-γ, and act as cytotoxic T cells against CD1d+ target cells following stimulation. The C21 antibody is useful for multiparameter cell sorting and phenotypic analyses designed to study the nature of TCR Vβ11-positive T cells and T cell clones. When combined with other TCR V region-specific antibodies, C15 is helpful for characterizing TCR Vβ repertoires expressed by T cell populations collected from blood, tissues or other sources in health and disease models including inflammation, infectious diseases, autoimmunity, and tumors.

759614 Rev. 1
Format Details
Down Arrow Up Arrow
BB700
The BD Horizon Brilliant™ Blue 700 (BB700) Dye is part of the BD Horizon Brilliant™ Blue family of dyes. This tandem fluorochrome is comprised of a polymer-technology dye donor with an excitation maximum (Ex Max) of 476-nm and an acceptor dye with an emission maximum (Em Max) at 695-nm. Driven by BD innovation, BB700 is designed to be excited by the blue laser (488-nm) and detected using an optical filter centered near 695-nm (e.g., a 695/20-nm bandpass filter). The donor dye can be excited by the Violet (405 nm) laser and the acceptor dye can be excited by the red (627–640 nm) laser resulting in cross-laser excitation and fluorescence spillover. BB700 Reagents are significantly brighter than equivalent PerCP or PerCP-Cy5.5 reagents and are less sensitive to photobleaching. In addition, BB700 shows much less excitation by the violet (407-nm) laser resulting in less spillover. BB700 has minimal yellow green (562-nm) excitation and is ideal for instruments with both blue (488-nm) and yellow green (562-nm) lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BB700
Blue 488 nm
476 nm
695 nm
759614 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "759614" on CiteAb

Development References (6)

  1. Cossarizza A, Chang HD, Radbruch A, et al. Guidelines for the use of flow cytometry and cell sorting in immunological studies (third edition).. Eur J Immunol. 2021; 51(12):2708-3145. (Clone-specific: Flow cytometry, Fluorescence activated cell sorting). View Reference
  2. Dellabona P, Padovan E, Casorati G, Brockhaus M, Lanzavecchia A. An invariant V alpha 24-J alpha Q/V beta 11 T cell receptor is expressed in all individuals by clonally expanded CD4-8- T cells.. J Exp Med. 1994; 180(3):1171-6. (Immunogen: Flow cytometry, Fluorescence activated cell sorting). View Reference
  3. Kojo S, Adachi Y, Keino H, Taniguchi M, Sumida T. Dysfunction of T cell receptor AV24AJ18+, BV11+ double-negative regulatory natural killer T cells in autoimmune diseases.. Arthritis Rheum. 2001; 44(5):1127-38. (Clone-specific: Flow cytometry). View Reference
  4. Lal KG, Leeansyah E, Sandberg JK, Eller MA. OMIP-046: Characterization of invariant T cell subset activation in humans.. Cytometry A. 2018; 93(5):499-503. (Clone-specific: Flow cytometry). View Reference
  5. Oishi Y, Sakamoto A, Kurasawa K, et al. CD4-CD8- T cells bearing invariant Valpha24JalphaQ TCR alpha-chain are decreased in patients with atopic diseases.. Clin Exp Immunol. 2000; 119(3):404-11. (Clone-specific: Flow cytometry). View Reference
  6. Thomas SY, Hou R, Boyson JE, et al. CD1d-restricted NKT cells express a chemokine receptor profile indicative of Th1-type inflammatory homing cells. J Immunol. 2003; 171(5):2571-2580. (Clone-specific: Flow cytometry). View Reference
View All (6) View Less
759614 Rev. 1

Please refer to Support Documents for Quality Certificates

 

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

 

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.