Skip to main content Skip to navigation
RB545 Mouse Anti-Human CD10
RB545 Mouse Anti-Human CD10

Multiparameter flow cytometric analysis of CD10 expression on Human peripheral blood leucocyte populations.  Human whole blood was first treated with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899) to lyse erythrocytes, washed, and then preincubated with BD Pharmingen™ Human BD Fc Block™ (Cat. No. 564219/564220). The leucocytes were then stained with either BD Horizon™ RB545 Mouse IgG1, κ Isotype Control (Cat. No. 569284; Left Plot) or BD Horizon™ RB545 Mouse Anti-Human CD10 antibody (Cat. No. 569738/569766; Right Plot). The bivariate pseudocolor density plot showing the correlated expression of CD10 (or Ig Isotype control staining) versus side light-scatter (SSC-A) signals was derived from gated events with the forward and side light-scatter characteristics of viable leucocytes. Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer and spectrally unmixed using FlowJo™ v10.8 software.

RB545 Mouse Anti-Human CD10

Flow cytometric analysis of CD10 expression on Human Reh cells. Cells from the Human Reh (Acute lymphocytic leukemia, ATCC® CRL-8286™) cell line were stained with either BD Horizon™ RB545 Mouse IgG1, κ Isotype Control (Cat. No. 569284; dashed line histogram) or BD Horizon™ RB545 Mouse Anti-Human CD10 antibody (Cat. No. 569738/569766; solid line histogram). DAPI (4',6-Diamidino-2-Phenylindole, Dihydrochloride) Solution (Cat. No. 564907) was added to cells right before analysis. The fluorescence histogram showing CD10 expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of viable (DAPI-negative) cells. Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer and spectrally unmixed using FlowJo™ v10.8 software.

Multiparameter flow cytometric analysis of CD10 expression on Human peripheral blood leucocyte populations.  Human whole blood was first treated with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899) to lyse erythrocytes, washed, and then preincubated with BD Pharmingen™ Human BD Fc Block™ (Cat. No. 564219/564220). The leucocytes were then stained with either BD Horizon™ RB545 Mouse IgG1, κ Isotype Control (Cat. No. 569284; Left Plot) or BD Horizon™ RB545 Mouse Anti-Human CD10 antibody (Cat. No. 569738/569766; Right Plot). The bivariate pseudocolor density plot showing the correlated expression of CD10 (or Ig Isotype control staining) versus side light-scatter (SSC-A) signals was derived from gated events with the forward and side light-scatter characteristics of viable leucocytes. Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer and spectrally unmixed using FlowJo™ v10.8 software.

Flow cytometric analysis of CD10 expression on Human Reh cells. Cells from the Human Reh (Acute lymphocytic leukemia, ATCC® CRL-8286™) cell line were stained with either BD Horizon™ RB545 Mouse IgG1, κ Isotype Control (Cat. No. 569284; dashed line histogram) or BD Horizon™ RB545 Mouse Anti-Human CD10 antibody (Cat. No. 569738/569766; solid line histogram). DAPI (4',6-Diamidino-2-Phenylindole, Dihydrochloride) Solution (Cat. No. 564907) was added to cells right before analysis. The fluorescence histogram showing CD10 expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of viable (DAPI-negative) cells. Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer and spectrally unmixed using FlowJo™ v10.8 software.

Product Details
Down Arrow Up Arrow


BD Horizon™
MME; CALLA; EPN; NEP; neprilysin; SFE; atriopeptidase; enkephalinase
Human (QC Testing), Rhesus,Cynomolgus,Baboon (Tested in Development)
Mouse BALB/c IgG1, κ
Acute CALLA Leukemia Blast Cells
Flow cytometry (Routinely Tested)
5 µl/test
V CD10.7
4311
AB_3685278
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unreacted dye was removed.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  3. An isotype control should be used at the same concentration as the antibody of interest.
  4. Please observe the following precautions: Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
  5. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  8. Species cross-reactivity detected in product development may not have been confirmed on every format and/or application.
  9. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  10. For U.S. patents that may apply, see bd.com/patents.
569766 Rev. 1
Antibody Details
Down Arrow Up Arrow
HI10a

The HI10a monoclonal antibody specifically binds to CD10 which is also known as Neutral endopeptidase (NEP), Enkephalinase, Atriopeptidase, and Neprilysin. CD10 is encoded by MME (membrane metallo-endopeptidase). CD10 is a 100 kDa type II transmembrane glycoprotein that has neutral endopeptidase activity and is otherwise known as the Common Acute Lymphoblastic Leukemia Antigen (CALLA). CD10 is expressed on a wide variety of normal and neoplastic cell types. Normal cells expressing CD10 include granulocytes, bone marrow stromal cells, a subset of B-cell progenitors, germinal center B cells and fibroblasts. This cell surface metalloendopeptidase inactivates a number of signaling molecules and serves as a major regulator in the nervous, immune and other systems.

569766 Rev. 1
Format Details
Down Arrow Up Arrow
RB545
The BD Horizon RealBlue™ 545 (RB545) fluorochrome is part of the BD family of blue (488-nm) laser dyes. It is a small organic fluorochrome with an excitation maximum (Ex Max) at 496-nm and an emission maximum (Em Max) at 545-nm. Driven by BD innovation, RB545 can be used on spectral cytometers and is designed to be excited by the blue (488-nm) laser with minimal excitation by the 561-nm yellow-green laser. RB545 has minimal spillover into yellow-green detectors and a brightness level similar to FITC.  Given its unique emission max, on a spectral instrument RB545 can be used simultaneously with FITC and PE to provide an additional color off of the blue laser. Please ensure that your instrument configuration (lasers and optical filters) is appropriate for this dye.
altImg
RB545
Blue 488 nm
496 nm
545 nm
569766 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "569766" on CiteAb

Development References (6)

  1. Bjornson-Hooper ZB, Fragiadakis GK, Spitzer MH, et al. A Comprehensive Atlas of Immunological Differences Between Humans, Mice, and Non-Human Primates.. Front Immunol. 2022; 13:867015. (Clone-specific: Flow cytometry). View Reference
  2. Letarte M, Vera S, Tran R, et al. Common acute lymphocytic leukemia antigen is identical to neutral endopeptidase. J Exp Med. 1988; 168(4):1247-1253. (Biology). View Reference
  3. Liechti T, Günthard HF, Trkola A. OMIP-047: High-Dimensional phenotypic characterization of B cells.. Cytometry A. 2018; 93(6):592-596. (Clone-specific: Flow cytometry). View Reference
  4. Lin G-X, Yang X, Hollemweguer E, et al. Cross-reactivity of CD antibodies in eight animal species. In: Mason D. David Mason .. et al., ed. Leucocyte typing VII : white cell differentiation antigens : proceedings of the Seventh International Workshop and Conference held in Harrogate, United Kingdom. Oxford: Oxford University Press; 2002:519-523.
  5. Zola H. CD10 Workshop Panel report. In: Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995:505-507.
  6. Zola H. Leukocyte and stromal cell molecules : the CD markers. Hoboken, N.J.: Wiley-Liss; 2007.
View All (6) View Less
569766 Rev. 1

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

Please refer to Support Documents for Quality Certificates

 

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

 

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.