RB670 Rat Anti-Mouse Siglec-H
Product Details
Down Arrow Up Arrow


BD OptiBuild™
Siglec H; Siglech; Sialic acid binding Ig-like lectin H; SIGLEC
Mouse (Tested in Development)
Rat IgG2b, κ
Mouse Bone Marrow IPC
Flow cytometry (Qualified)
0.2 mg/ml
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation).  When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells.  However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls.  It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  3. For U.S. patents that may apply, see bd.com/patents.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  6. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  7. When using high concentrations of antibody, background binding of this dye to erythroid fragments produced by ammonium chloride-based lysis, such as with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899), has been observed when the antibody conjugate was present during the lysis procedure. This may cause nonspecific staining of target cells, such as leukocytes, which have bound the resulting erythroid fragments. This background can be mitigated by any of the following: titrating the antibody conjugate to a lower concentration, fixing samples with formaldehyde, or removing erythrocytes before staining (eg, gradient centrifugation or pre-lysis with wash). This background has not been observed when cells were lysed with BD FACS™ Lysing Solution (Cat. No. 349202) after staining.
  8. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  9. An isotype control should be used at the same concentration as the antibody of interest.
  10. Please observe the following precautions: We recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to protect exposure of conjugated reagents, including cells stained with those reagents, to any room illumination. Absorption of visible light can significantly affect the emission spectra and quantum yield of tandem fluorochrome conjugates.
  11. Tandem fluorochromes contain both an energy donor and an energy acceptor. Although every effort is made to minimize the lot-to-lot variation in the efficiency of the fluorochrome energy transfer, differences in the residual emission from the donor may be observed. Additionally, multi-laser cytometers may directly excite both the donor and acceptor fluorochromes. Therefore, we recommend for every tandem conjugate, a matched individual single-stain control be acquired for generating a compensation or spectral unmixing matrix.
  12. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.
771076 Rev. 1
Antibody Details
Down Arrow Up Arrow
440c

The 440c monoclonal antibody specifically recognizes Siglec-H, a type I transmembrane glycoprotein that is encoded by Siglech (Sialic acid binding Ig-like lectin H). Siglec-H contains two immunoglobulin domains in its extracellular region and a cytoplasmic domain that lacks tyrosine-based signaling motifs unlike other CD33-related Siglec-like molecules. Siglec-H is expressed on progenitors of plasmacytoid dendritic cells (pDCs) and depends on DAP12 for cell surface expression and intracellular signaling function. In addition to its expression on pDC, Siglec-H may also be expressed by splenic marginal zone macrophages, medullary macrophages in lymph nodes, and microglia. Siglec-H may regulate the production of type I interferons (IFN-I) by pDCs and other cell types. There is no clear human ortholog for mouse Siglec-H.

771076 Rev. 1
Format Details
Down Arrow Up Arrow
RB670
The BD Horizon RealBlue™ 670 (RB670) Dye is part of the BD® family of blue dyes. It is a tandem fluorochrome with an excitation maximum (Ex Max) at 492 nm and an emission maximum (Em Max) at 670 nm as measured using an antibody-dye conjugate. Driven by BD® innovation, RB670 can be used on both spectral and conventional cytometers and is designed to be primarily excited by the Blue laser (488-nm). For conventional instruments equipped with only a Blue laser (488-nm), RB670 can be used as an alternative to PE-Cy5 and we recommend using an optical filter centered near 670-nm (eg, a 670/30-nm bandpass filter). For conventional and spectral instruments equipped with both a Blue (488-nm) and Yellow-Green (561-nm) laser and appropriate detectors, it can be used in conjunction with PE-Cy5.
altImg
RB670
Blue 488 nm
492 nm
670 nm
771076 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "771076" on CiteAb

Development References (8)

  1. Blasius A, Vermi W, Krug A, Facchetti F, Cella M, Colonna M. A cell-surface molecule selectively expressed on murine natural interferon-producing cells that blocks secretion of interferon-alpha.. Blood. 2004; 103(11):4201-6. (Immunogen: Flow cytometry, Fluorescence activated cell sorting, Functional assay, Immunohistochemistry, Inhibition, In vivo exacerbation). View Reference
  2. Blasius AL, Cella M, Maldonado J, Takai T, Colonna M. Siglec-H is an IPC-specific receptor that modulates type I IFN secretion through DAP12.. Blood. 2006; 107(6):2474-6. (Clone-specific: Flow cytometry). View Reference
  3. Blasius AL, Giurisato E, Cella M, Schreiber RD, Shaw AS, Colonna M. Bone marrow stromal cell antigen 2 is a specific marker of type I IFN-producing cells in the naive mouse, but a promiscuous cell surface antigen following IFN stimulation.. J Immunol. 2006; 177(5):3260-5. (Clone-specific: Flow cytometry). View Reference
  4. Schmitt H, Sell S, Koch J, et al. Siglec-H protects from virus-triggered severe systemic autoimmunity.. J Exp Med. 2016; 213(8):1627-44. (Biology). View Reference
  5. Swiecki M, Gilfillan S, Vermi W, Wang Y, Colonna M. Plasmacytoid dendritic cell ablation impacts early interferon responses and antiviral NK and CD8(+) T cell accrual.. Immunity. 2010; 33(6):955-66. (Clone-specific: Flow cytometry). View Reference
  6. Swiecki M, Wang Y, Riboldi E, et al. Cell depletion in mice that express diphtheria toxin receptor under the control of SiglecH encompasses more than plasmacytoid dendritic cells.. J Immunol. 2014; 192(9):4409-16. (Clone-specific: Flow cytometry, Fluorescence activated cell sorting). View Reference
  7. Swiecki M, Wang Y, Vermi W, Gilfillan S, Schreiber RD, Colonna M. Type I interferon negatively controls plasmacytoid dendritic cell numbers in vivo.. J Exp Med. 2011; 208(12):2367-74. (Clone-specific: Immunohistochemistry). View Reference
  8. Zhang J, Raper A, Sugita N, et al. Characterization of Siglec-H as a novel endocytic receptor expressed on murine plasmacytoid dendritic cell precursors.. Blood. 2006; 107(9):3600-8. (Biology). View Reference
View All (8) View Less
771076 Rev. 1

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.

Refer to manufacturer's instructions for use and related User Manuals and Technical Data Sheets before using this product as described.

Comparisons, where applicable, are made against older BD technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.