Skip to main content Skip to navigation
PE Mouse Anti-Human IL-12 (p40/p70)
PE Mouse Anti-Human IL-12 (p40/p70)
Expression of IL-12 p40/p70 by HiCK-3 cells. Ficoll™-separated human PBMCs were primed for 2 hours with recombinant human IFN-γ (20 ng/ml final concentration; Cat. No. 554616), then activated with IFN-γ(20 ng/ml final concentration) and LPS (1 µg/ml final concentration; Sigma) in the presence of BD GolgiStop™ (2 µM final concentration; Cat. No. 554724) for an additional 22 hours. Cells were harvested, fixed, permeabilized, and then stained with 20 µl of PE-C11.5 antibody (Cat. No. 559329), by following the Usage section above and Pharmingen's staining protocol (left panel). The data reflect gating on monocytes, based on forward and side scattered light signals. To demonstrate specificity of staining, the binding of PE-C11.5 antibody was blocked by preincubation of the conjugated antibody with an excess of the unlabelled C11.5 antibody (5 µg, Cat. No. 554573; right panel). The quadrant markers for the bivariate dot plots were set based on the autofluorescence control, and verified with the recombinant cytokine blocking and unlabelled antibody blocking specificity controls.
Expression of IL-12 p40/p70 by HiCK-3 cells. Ficoll™-separated human PBMCs were primed for 2 hours with recombinant human IFN-γ (20 ng/ml final concentration; Cat. No. 554616), then activated with IFN-γ(20 ng/ml final concentration) and LPS (1 µg/ml final concentration; Sigma) in the presence of BD GolgiStop™ (2 µM final concentration; Cat. No. 554724) for an additional 22 hours. Cells were harvested, fixed, permeabilized, and then stained with 20 µl of PE-C11.5 antibody (Cat. No. 559329), by following the Usage section above and Pharmingen's staining protocol (left panel). The data reflect gating on monocytes, based on forward and side scattered light signals. To demonstrate specificity of staining, the binding of PE-C11.5 antibody was blocked by preincubation of the conjugated antibody with an excess of the unlabelled C11.5 antibody (5 µg, Cat. No. 554573; right panel). The quadrant markers for the bivariate dot plots were set based on the autofluorescence control, and verified with the recombinant cytokine blocking and unlabelled antibody blocking specificity controls.
Product Details
Down Arrow Up Arrow


BD Pharmingen™
Human (QC Testing)
Mouse IgG1
CHO-expressed recombinant human IL-12 p70 heterodimer
Intracellular staining (flow cytometry) (Routinely Tested)
20 µl
AB_397226
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation And Storage

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with R-PE under optimum conditions, and unconjugated antibody and free PE were removed. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

Recommended Assay Procedures

Immunofluorescent Staining and Flow Cytometric Analysis: The C11.5 antibody is useful for immunofluorescent staining and flow cytometric analysis to identify and enumerate IL-12 producing cells within mixed cell populations. This 100 Test Size formulation of the PE-conjugated C11.5 antibody has been pre-titrated to assure effective intracellular detection of human IL-12 using 20 µl/1 x 10e6 cells.

A useful control for demonstrating specificity of staining is either of the following: 1) pre-block the fluorochrome-conjugated C11.5 antibody with excess ligand (e.g., recombinant human IL-12 p70, (Cat. No. 554613) or recombinant human IL-12 p40, (Cat. No. 554633) prior to staining, or 2) pre-block the fixed/permeabilized cells with unlabelled C11.5 antibody (Cat. No. 554573) prior to staining. The intracellular staining technique and use of blocking controls are described in detail by C. Prussin and D. Metcalfe. A suitable mouse IgG1 isotype control for assessing the level of background staining on paraformaldehyde-fixed/saponin-permeabilized human cells is also available in a 100 Test Size formulation PE-MOPC-21 (Cat. No. 559320).

Important Note: This pre-titered antibody solution does not contain a cell permeabilization agent. It is necessary to include a cell permeabilization agent when using the pre-titered antibody solution to stain fixed and permeabilized cells. BD Perm/Wash™ Buffer (Cat. No. 554723) contains the permeabilization agent saponin and is useful for this purpose as described in the Usage section.

Usage

1. Resuspend 1 x 10e6 fixed and permeabilized cells in 20 µl of the pre-titered antibody solution and 30 µl of 1X BD Perm/Wash Buffer (Cat. No. 554723).

2. Incubate the cell suspension for 15 minutes (at RT or 4°C).

3. Wash twice in 100 µl of 1X BD Perm/Wash Buffer (Cat. No. 554723).

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  3. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  6. Ficoll-Paque is a trademark of Amersham Biosciences Limited.
559329 Rev. 2
Antibody Details
Down Arrow Up Arrow
C11.5

The C11.5 monoclonal antibody specifically binds to the human IL-12 p40 monomer and p70 heterodimer, but does not bind to the IL-12 p35 monomer. The immunogen used to generate the C11.5 hybridoma was the CHO-expressed recombinant human IL-12 p70 heterodimer.  p40 has also been described as a subunit of IL-23 and thus it is possible that the C11.5 antibody crossreacts with IL-23.

559329 Rev. 2
Format Details
Down Arrow Up Arrow
PE
R-Phycoerythrin (PE), is part of the BD family of Phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 496 nm and 566 nm and an emission maximum (Em Max) at 576 nm. PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 575/26-nm bandpass filter). As PE is excited by multiple lasers, this can result in cross-laser excitation and fluorescence spillover on instruments with various combinations of Blue, Green, and Yellow-Green lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
576 nm
559329 Rev.2
Citations & References
Down Arrow Up Arrow

Development References (5)

  1. D'Andrea A, Aste-Amezaga M, Valiante NM, Ma X, Kubin M, Trinchieri G. Interleukin 10 (IL-10) inhibits human lymphocyte interferon gamma-production by suppressing natural killer cell stimulatory factor/IL-12 synthesis in accessory cells. J Exp Med. 1993; 178(3):1041-1048. (Clone-specific). View Reference
  2. D'Andrea A, Rengaraju M, Valiante NM, et al. Production of natural killer cell stimulatory factor (interleukin 12) by peripheral blood mononuclear cells. J Exp Med. 1992; 176(5):1387-1398. (Clone-specific). View Reference
  3. Gately MK, Chizzonite R, Presky DH. Measurement of Human and Mouse Interleukin-12. In: Cooligan J, Kruisbeek A, Margulies D, Shevach E, Storber W, ed. Current Protocols in Immunology. New York: John Wiley and Sons; 1995:6-16.
  4. Oppmann B, Lesley R, Blom B, et al. Novel p19 protein engages IL-12p40 to form a cytokine, IL-23, with biological activities similar as well as distinct from IL-12.. Immunity. 2000; 13(5):715-25. (Biology). View Reference
  5. Prussin C, Metcalfe DD. Detection of intracytoplasmic cytokine using flow cytometry and directly conjugated anti-cytokine antibodies. J Immunol Methods. 1995; 188(1):117-128. (Methodology: IC/FCM Block). View Reference
View All (5) View Less
559329 Rev. 2

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.

Refer to manufacturer's instructions for use and related User Manuals and Technical Data Sheets before using this product as described.

Comparisons, where applicable, are made against older BD technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.