Skip to main content Skip to navigation
Biotin Hamster Anti-Mouse CD11c
Biotin Hamster Anti-Mouse CD11c
Flow cytometric analysis of CD11c expression on mouse splenocytes. Spleen NK cells were stained with PE Mouse Anti-Mouse NK-1.1 (Cat. No. 557391/553165) and either Biotin Hamster IgG Isotype Control (Cat. No. 553952; left panel) or Biotin Hamster anti-Mouse CD11c antibody (Cat. No. 553800; right panel). Secondary staining was carried out with Avidin FITC (Cat. No. 553800). The contour plots were derived from events with the forward and side light-scatter characteristics of viable splenocytes. Flow cytometric analysis was performed using a BD FACSCan™ flow cytometry system.
Flow cytometric analysis of CD11c expression on mouse splenocytes. Spleen NK cells were stained with PE Mouse Anti-Mouse NK-1.1 (Cat. No. 557391/553165) and either Biotin Hamster IgG Isotype Control (Cat. No. 553952; left panel) or Biotin Hamster anti-Mouse CD11c antibody (Cat. No. 553800; right panel). Secondary staining was carried out with Avidin FITC (Cat. No. 553800). The contour plots were derived from events with the forward and side light-scatter characteristics of viable splenocytes. Flow cytometric analysis was performed using a BD FACSCan™ flow cytometry system.
Product Details
Down Arrow Up Arrow


BD Pharmingen™
Cd11c; Itgax; Integrin alpha-X; Integrin αX; Cr4; Complement receptor 4
Mouse (QC Testing)
Armenian Hamster IgG1, λ2
C57BL/6 Mouse Intestinal Intraepithelial Lymphocytes
Flow cytometry (Routinely Tested)
0.5 mg/ml
16411
AB_395059
Aqueous buffered solution containing protein stabilizer and ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with biotin under optimum conditions, and unreacted biotin was removed.

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. Although hamster immunoglobulin isotypes have not been well defined, BD Biosciences Pharmingen has grouped Armenian and Syrian hamster IgG monoclonal antibodies according to their reactivity with a panel of mouse anti-hamster IgG mAbs. A table of the hamster IgG groups, Reactivity of Mouse Anti-Hamster Ig mAbs, may be viewed at http://www.bdbiosciences.com/documents/hamster_chart_11x17.pdf.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
553800 Rev. 13
Antibody Details
Down Arrow Up Arrow
HL3

The HL3 monoclonal antibody specifically binds to the integrin αx chain of gp150, 95 (CD11c/CD18). CD11c is expressed on dendritic cells, CD4- CD8+ intestinal intraepithelial lymphocytes (IEL) and some NK cells. It is upregulated on IEL and lymph-node T cells following in vivo activation. Cells of the monocyte/macrophage lineage have been reported to express low levels of CD11c. CD11c plays a role in binding of iC3b.

553800 Rev. 13
Format Details
Down Arrow Up Arrow
Biotin
Biotin is a ubiquitous co-factor (also known as Vitamin B7) that has many properties that make it extremely useful for molecular biology. Biotin has an extremely high affinity for the Avidin family of proteins (Kd = 10-15 M), making it the perfect tool to link two molecules. Biotin labeled antibodies can be combined with any number of Avidin-conjugated probes in order to customize an assay to a particular need. This is especially useful in the case of magnetic cell separation using streptavidin/magnetic bead conjugates, or in the case of flow cytometry using streptavidin/fluorophore conjugates.
Biotin
553800 Rev.13
Citations & References
Down Arrow Up Arrow

Development References (7)

  1. Barclay NA, Brown MH, Birkeland ML, et al, ed. The Leukocyte Antigen FactsBook. San Diego, CA: Academic Press; 1997.
  2. Burt BM, Plitas G, Stableford JA, et al. CD11c identifies a subset of murine liver natural killer cells that responds to adenoviral hepatitis. J Leukoc Biol. 2008; 84(4):1039-1046. (Clone-specific). View Reference
  3. Gao JX, Liu X, Wen J, et al. Differentiation of monocytic cell clones into CD8 alpha+ dendritic cells (DC) suggests that monocytes can be direct precursors for both CD8 alpha+ and CD8 alpha- DC in the mouse. J Immunol. 2003; 170(12):5927-5935. (Biology). View Reference
  4. Huleatt JW, Lefrançois L. Antigen-driven induction of CD11c on intestinal intraepithelial lymphocytes and CD8+ T cells in vivo.. J Immunol. 1995; 154(11):5684-93. (Immunogen: Immunoprecipitation). View Reference
  5. Larson RS, Springer TA. Structure and function of leukocyte integrins. Immunol Rev. 1990; 114:181-217. (Biology). View Reference
  6. Maraskovsky E, Brasel K, Teepe M, et al. Dramatic increase in the numbers of functionally mature dendritic cells in Flt3 ligand-treated mice: multiple dendritic cell subpopulations identified. J Exp Med. 1996; 184(5):1953-1962. (Biology). View Reference
  7. Pulendran B, Lingappa J, Kennedy MK, et al. Developmental pathways of dendritic cells in vivo: distinct function, phenotype, and localization of dendritic cell subsets in FLT3 ligand-treated mice. J Immunol. 1997; 159(5):2222-2231. (Clone-specific: Immunohistochemistry). View Reference
View All (7) View Less
553800 Rev. 13

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.

Refer to manufacturer's instructions for use and related User Manuals and Technical Data Sheets before using this product as described.

Comparisons, where applicable, are made against older BD technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.