RB744 Mouse Anti-Human IL-13RA2 (CD213a2)

BD OptiBuild™ RB744 Mouse Anti-Human IL-13RA2 (CD213a2)

Clone 47 (also known as Clone 47; mAb47; 47 mAb)

(RUO)
Product Details
Down Arrow Up Arrow


BD OptiBuild™
CD213A2; IL-13 receptor subunit alpha-2; IL-13R; IL-13Rα2; cancer/testis antigen 19
Human (Tested in Development)
Mouse BALB/c IgG1, κ
Human rhIL13Ra2hFc
Flow cytometry (Qualified)
0.2 mg/ml
3598
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  3. For U.S. patents that may apply, see bd.com/patents.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  6. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  7. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  8. When using high concentrations of antibody, background binding of this dye to erythroid fragments produced by ammonium chloride-based lysis, such as with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899), has been observed when the antibody conjugate was present during the lysis procedure. This may cause nonspecific staining of target cells, such as leukocytes, which have bound the resulting erythroid fragments. This background can be mitigated by any of the following: titrating the antibody conjugate to a lower concentration, fixing samples with formaldehyde, or removing erythrocytes before staining (eg, gradient centrifugation or pre-lysis with wash). This background has not been observed when cells were lysed with BD FACS™ Lysing Solution (Cat. No. 349202) after staining.
  9. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  10. An isotype control should be used at the same concentration as the antibody of interest.
  11. Please observe the following precautions: We recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to protect exposure of conjugated reagents, including cells stained with those reagents, to any room illumination. Absorption of visible light can significantly affect the emission spectra and quantum yield of tandem fluorochrome conjugates.
758115 Rev. 1
Antibody Details
Down Arrow Up Arrow
47

Clone 47 is a monoclonal antibody that specifically recognizes the Human Interleukin-13 Receptor Subunit Alpha-2 (IL-13RA2), also known as IL-13Rα2 or CD213a2. IL-13RA2 (CD213a2) is a ~42 kDa type I transmembrane glycoprotein that is encoded by IL13RA2 which belongs to the type I cytokine receptor family. The extracellular domain is comprised of three extracellular fibronectin type III domains and a WSXWS motif that is followed by a transmembrane segment and a short cytoplasmic tail. Although this receptor primarily exists in a membrane-bound form, a soluble form may be generated upon enzymatic cleavage. IL-13RA2 (CD213a2) binds IL-13 with higher affinity than the moderate affinity IL-13RA1 (CD213a) subunit of the Type II IL-4R complex. This heterodimeric receptor complex is comprised of IL-4RA (CD124) and IL-13RA1 (CD213a) and transduces signals in response to either bound IL-4 or IL-13 ligands. IL-13RA2 (CD213a2) thus appears to act as a decoy receptor due to its short cytoplasmatic tail and lack of signaling motifs and thus controls the bioavailability and activity of IL-13. It is expressed by a subset of peripheral blood lymphocytes and immature dendritic cells. It is also known as cancer/testis antigen 19 (CT19) and may be highly expressed by a variety of malignant cells including high-grade gliomas.

758115 Rev. 1
Format Details
Down Arrow Up Arrow
RB744
The BD Horizon RealBlue™ 744 (RB744) Dye is part of the BD® family of blue dyes. It is a tandem fluorochrome with an excitation maximum (Ex Max) at 498-nm and an emission maximum (Em Max) at 746-nm as measured using an antibody-dye conjugate. Driven by BD® innovation, RB744 can be used on both spectral and conventional cytometers and is designed to be excited by the Blue laser (488-nm) with minimal excitation by the 561-nm Yellow-Green laser. For conventional instruments equipped with a Blue laser (488-nm), we recommend using an optical filter centered near 750-nm (e.g., a 750/60-nm bandpass filter).
altImg
RB744
Blue 488 nm
498 nm
746 nm
758115 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "758115" on CiteAb

Development References (8)

  1. Balyasnikova IV, Wainwright DA, Solomaha E, et al. Characterization and immunotherapeutic implications for a novel antibody targeting interleukin (IL)-13 receptor α2.. J Biol Chem. 2012; 287(36):30215-27. (Immunogen). View Reference
  2. Hershey GK. IL-13 receptors and signaling pathways: an evolving web.. J Allergy Clin Immunol. 2003; 111(4):677-90; quiz 691. (Biology). View Reference
  3. Lupardus PJ, Birnbaum ME, Garcia KC. Molecular basis for shared cytokine recognition revealed in the structure of an unusually high affinity complex between IL-13 and IL-13Ralpha2.. Structure. 2010; 18(3):332-42. (Biology). View Reference
  4. Penke LR, Ouchi H, Speth JM, et al. Transcriptional regulation of the IL-13Rα2 gene in human lung fibroblasts.. Sci Rep. 2020; 10(1):1083. (Biology). View Reference
  5. Tabata Y, Khurana Hershey GK. IL-13 receptor isoforms: breaking through the complexity.. Curr Allergy Asthma Rep. 2007; 7(5):338-45. (Biology). View Reference
  6. Takenouchi M, Hirai S, Sakuragi N, Yagita H, Hamada H, Kato K. Epigenetic modulation enhances the therapeutic effect of anti-IL-13R(alpha)2 antibody in human mesothelioma xenografts.. Clin Cancer Res. 2011; 17(9):2819-29. (Biology). View Reference
  7. Thaci B, Brown CE, Binello E, Werbaneth K, Sampath P, Sengupta S. Significance of interleukin-13 receptor alpha 2-targeted glioblastoma therapy.. Neuro Oncol. 2014; 16(10):1304-12. (Biology). View Reference
  8. Zola H, Swart B, Nicholson I, Voss E. CD213α1 and 2. In: Zola H. Leukocyte and stromal cell molecules : the CD markers. Hoboken, N.J.: Wiley-Liss; 2007:359-360.
View All (8) View Less
758115 Rev. 1

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.