Skip to main content Skip to navigation
BUV661 Mouse Anti-Human TCR Vβ13.2
Product Details
Down Arrow Up Arrow


BD OptiBuild™
TCR V beta 13.2; TCR Vb13.2; TCRBV13S2; TCRBV6S2; TRBV6-2; TRBV62
Human (Tested in Development)
Mouse SWR IgG1, κ
Human TCR Vβ13.2 Element Transfected Cell Line
Flow cytometry (Qualified)
0.2 mg/ml
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation).  When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells.   However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls.  It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime BD Horizon Brilliant dyes are used in a multicolor flow cytometry panel.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. When BD Horizon Brilliant Stain Buffer is used in in the multicolor panel, it should also be used in the corresponding compensation controls for all dyes to achieve the most accurate compensation. For the most accurate compensation, compensation controls created with either cells or beads should be exposed to BD Horizon Brilliant Stain Buffer for the same length of time as the corresponding multicolor panel. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).

Note:  When using high concentrations of antibody, background binding of this dye to erythroid cell subsets (mature erythrocytes and precursors) has been observed.  For researchers studying these cell populations, or in cases where light scatter gating does not adequately exclude these cells from the analysis, this background may be an important factor to consider when selecting reagents for panel(s).

Product Notices

  1. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  2. Researchers should determine the optimal concentration of this reagent for their individual applications.
  3. An isotype control should be used at the same concentration as the antibody of interest.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  7. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  8. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  9. BD Horizon Brilliant Ultraviolet 661 is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,227,187; 8,575,303; 8,354,239.
  10. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
753810 Rev. 1
Antibody Details
Down Arrow Up Arrow
H132

The H132 monoclonal antibody specifically recognizes the variable beta 13.2 region of the β subunit of the human αβ T cell receptor for antigen (TCR Vβ13.2). TCR Vβ13.2 is expressed on subsets of TCR αβ positive thymocytes and peripheral CD4+ and CD8+ T cells. The H132 antibody is useful for multiparameter analyses designed to study the nature of TCR Vβ13.2-positive cells including normal T cells as well as T cell clones, hybridomas, or tumors. It is also useful for analyzing TCR Vβ repertoires expressed by T cell populations collected from blood, tissues or other sources in health and disease models including inflammation, autoimmunity, responses to superantigens, tumors, and infectious diseases including HIV infection. The H132 antibody can reportedly stimulate the proliferation of TCR Vβ13.2-positive T cells. The H132 antibody recognizes human TCR Vβ13.2 subfamily members but does not react with other human TCR Vβ13 family members including TCR Vβ13.1, Vβ13.3, Vβ13.5 and Vβ13.6 subfamily members.

753810 Rev. 1
Format Details
Down Arrow Up Arrow
BUV661
The BD Horizon Brilliant™ Ultraviolet 661 (BUV661) Dye is part of the BD Horizon Brilliant™ Ultraviolet family of dyes. This tandem fluorochrome is comprised of a BUV395 donor with an excitation maximum (Ex Max) of 350-nm and an acceptor dye with an emission maximum (Em Max) at 660-nm. BUV661, driven by BD innovation, is designed to be excited by the ultraviolet laser (355-nm) and detected using an optical filter centered near 660-nm (e.g., 670/25 bandpass filter). The acceptor dye can be excited by the Red (628–640-nm) laser resulting in cross-laser excitation and fluorescence spillover. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
BUV661
Ultraviolet 355 nm
350 nm
660 nm
753810 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "753810" on CiteAb

Development References (5)

  1. Choi YW, Kotzin B, Lafferty J, et al. A method for production of antibodies to human T-cell receptor beta-chain variable regions.. Proc Natl Acad Sci USA. 1991; 88(19):8357-61. (Immunogen: Flow cytometry, Functional assay, Stimulation). View Reference
  2. Dong T, Stewart-Jones G, Chen N, et al. HIV-specific cytotoxic T cells from long-term survivors select a unique T cell receptor.. J Exp Med. 2004; 200(12):1547-57. (Biology). View Reference
  3. Mongkolsapaya J, Jaye A, Callan MF, Magnusen AF, McMichael AJ, Whittle HC. Antigen-specific expansion of cytotoxic T lymphocytes in acute measles virus infection.. J Virol. 1999; 73(1):67-71. (Clone-specific: Flow cytometry). View Reference
  4. Moss P, Gillespie G, Frodsham P, Bell J, Reyburn H. Clonal populations of CD4+ and CD8+ T cells in patients with multiple myeloma and paraproteinemia. Blood. 1996; 87(8):3296-3306. (Clone-specific: Flow cytometry). View Reference
  5. Salameire D, Solly F, Fabre B, et al. Accurate detection of the tumor clone in peripheral T-cell lymphoma biopsies by flow cytometric analysis of TCR-Vβ repertoire.. Mod Pathol. 2012; 25(9):1246-57. (Clone-specific: Flow cytometry). View Reference
View All (5) View Less
753810 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.