Skip to main content Skip to navigation
RB780 Mouse Anti-Human HLA-ABC
RB780 Mouse Anti-Human HLA-ABC
Multiparameter flow cytometric analysis using BD OptiBuild™ RB780 Mouse Anti-Human HLA-ABC antibody (Cat. No. 755899; Right Plot) on human peripheral blood, with corresponding Isotype Control (Cat. No. 568532; Left Plot). Flow cytometry was performed using a BD LSRFortessa™ X-20 Flow Cytometer System.
Multiparameter flow cytometric analysis using BD OptiBuild™ RB780 Mouse Anti-Human HLA-ABC antibody (Cat. No. 755899; Right Plot) on human peripheral blood, with corresponding Isotype Control (Cat. No. 568532; Left Plot). Flow cytometry was performed using a BD LSRFortessa™ X-20 Flow Cytometer System.
Product Details
Down Arrow Up Arrow


BD OptiBuild™
Major histocompatibility complex, class I, A,B,C; HLA class I A,B,C
Human (Tested in Development)
Mouse IgG1, κ
Flow cytometry (Qualified)
0.2 mg/ml
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. When using high concentrations of antibody, background binding of this dye to erythroid fragments produced by ammonium chloride-based lysis, such as with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899), has been observed when the antibody conjugate was present during the lysis procedure. This may cause nonspecific staining of target cells, such as leukocytes, which have bound the resulting erythroid fragments. This background can be mitigated by any of the following: titrating the antibody conjugate to a lower concentration, fixing samples with formaldehyde, or removing erythrocytes before staining (eg, gradient centrifugation or pre-lysis with wash). This background has not been observed when cells were lysed with BD FACS™ Lysing Solution (Cat. No. 349202) after staining.
  2. Researchers should determine the optimal concentration of this reagent for their individual applications.
  3. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  4. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  5. Please observe the following precautions: Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
  6. An isotype control should be used at the same concentration as the antibody of interest.
  7. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  8. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  9. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  10. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  11. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.
  12. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
755899 Rev. 2
Antibody Details
Down Arrow Up Arrow
G46-2.6

The Human Leukocyte Antigen (HLA) complex is the human version of the MHC, helping the immune system distinguish the body's own proteins versus those from foreign invaders, such as viruses.  Humans have three main MHC class I genes, known as HLA-A, HLA-B and HLA-C.  Major histocompatibility complex (MHC) class I molecules, which are widely found on the surface of nucleated cells, function by binding peptides and displaying them on the cell surface to cytotoxic T-cells.  Intracellular degradation of cytosolic proteins by the proteasome generates many of the peptides that load MHC class I molecules.  MHC class I may also serve as an inhibitory ligand for natural killer (NK) cell receptors (KIR, Killer Immunoglobulin-like Receptors), which viruses may modulate expression levels for to evade immune detection.  The G46-2.6 monoclonal antibody binds to a monomorphic epitope on the alpha chain of HLA-A, HLA-B and HLA-C.

755899 Rev. 2
Format Details
Down Arrow Up Arrow
RB780
The BD Horizon RealBlue™ 780 (RB780) Dye is part of the BD family of blue dyes. It is a tandem fluorochrome with an excitation maximum (Ex Max) at 498-nm and an emission maximum (Em Max) at 781-nm. Driven by BD innovation, RB780 can be used on both spectral and conventional cytometers and is designed to be excited by the Blue laser (488-nm) with minimal excitation by the 561-nm Yellow-Green laser. For conventional instruments equipped with a Blue laser (488-nm), RB780 can be used as an alternative to PE-Cy7 and we recommend using an optical filter centered near 780-nm (eg, a 780/60-nm bandpass filter). For spectral instruments equipped with a Blue laser (488-nm), it can be used in conjunction with PE-Cy7. RB780 is on average brighter than PE-Cy7 and has minimal spillover into Yellow-Green detectors.
altImg
RB780
Blue 488 nm
498 nm
781 nm
755899 Rev.2
Citations & References
Down Arrow Up Arrow
View product citations for antibody "755899" on CiteAb

Development References (5)

  1. Barclay NA, Brown MH, Birkeland ML, et al, ed. The Leukocyte Antigen FactsBook. San Diego, CA: Academic Press; 1997.
  2. Crisa L, Cirulli V, Ellisman MH, Ishii JK, Elices MJ, Salomon DR. Cell adhesion and migration are regulated at distinct stages of thymic T cell development: the roles of fibronectin, VLA4, and VLA5. J Exp Med. 1996; 184(1):215-228. (Clone-specific: Flow cytometry). View Reference
  3. Kap YS, van Meurs M, van Driel N, et al. A monoclonal antibody selection for immunohistochemical examination of lymphoid tissues from non-human primates. J Histochem Cytochem. 2009; 57(12):1159-1167. (Clone-specific: Immunohistochemistry). View Reference
  4. Koppelman B, Neefjes JJ, de Vries JE, de Waal Malefyt R. Interleukin-10 down-regulates MHC class II alphabeta peptide complexes at the plasma membrane of monocytes by affecting arrival and recycling. Immunity. 1997; (6):861-871. (Clone-specific: Flow cytometry). View Reference
  5. Xia H, Liu H, Zhang G, Zheng Y. Phenotype and function of monocyte-derived dendritic cells from chinese rhesus macaques. Cell Mol Immunol. 2009; 6(3):159-165. (Clone-specific: Flow cytometry). View Reference
View All (5) View Less
755899 Rev. 2

Please refer to Support Documents for Quality Certificates

 

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

 

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.