Skip to main content Skip to navigation
RB744 Mouse Anti-Human CD134 (OX40)
RB744 Mouse Anti-Human CD134 (OX40)
Flow cytometric analysis using BD OptiBuild™ RB744 Mouse Anti-Human CD134 (OX40) antibody (Cat. No. 757710; solid line histogram) on Human peripheral blood mononuclear cells stimulated by PHA for 3 days, with corresponding IgG Isotype Control (Cat. No. 570519; dashed line histogram). Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer.
Flow cytometric analysis using BD OptiBuild™ RB744 Mouse Anti-Human CD134 (OX40) antibody (Cat. No. 757710; solid line histogram) on Human peripheral blood mononuclear cells stimulated by PHA for 3 days, with corresponding IgG Isotype Control (Cat. No. 570519; dashed line histogram). Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer.
Product Details
Down Arrow Up Arrow


BD OptiBuild™
OX40; OX 40; OX40L Receptor; TNFRSF4; ACT35; TXGP1L; OX40L Receptor; IMD16
Human (Tested in Development)
Mouse BALB/c IgG1, κ
Phytohemagglutinin-activated T lymphocytes
Flow cytometry (Qualified)
0.2 mg/ml
7293
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  3. For U.S. patents that may apply, see bd.com/patents.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  6. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  7. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  8. When using high concentrations of antibody, background binding of this dye to erythroid fragments produced by ammonium chloride-based lysis, such as with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899), has been observed when the antibody conjugate was present during the lysis procedure. This may cause nonspecific staining of target cells, such as leukocytes, which have bound the resulting erythroid fragments. This background can be mitigated by any of the following: titrating the antibody conjugate to a lower concentration, fixing samples with formaldehyde, or removing erythrocytes before staining (eg, gradient centrifugation or pre-lysis with wash). This background has not been observed when cells were lysed with BD FACS™ Lysing Solution (Cat. No. 349202) after staining.
  9. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  10. An isotype control should be used at the same concentration as the antibody of interest.
  11. Please observe the following precautions: We recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to protect exposure of conjugated reagents, including cells stained with those reagents, to any room illumination. Absorption of visible light can significantly affect the emission spectra and quantum yield of tandem fluorochrome conjugates.
757710 Rev. 2
Antibody Details
Down Arrow Up Arrow
L106

The L106 monoclonal antibody specifically recognizes CD134 which is also known as OX40, OX40L receptor or TAX transcriptionally-activated glycoprotein 1 receptor (TXGP1L). CD134 is a ~48 kDa type I transmembrane glycoprotein that is encoded by TNFRSF4 (TNF receptor superfamily member 4) and belongs to the TNF/NGF receptor family. By sequence analysis, CD134 is related to the antigen recognized by the rat monoclonal antibody Ox 40. The CD134 antigen (Human Ox 40) is found on activated peripheral CD4+ T lymphocytes and a subset of activated CD8+ T lymphocytes. It is not expressed on CD3-activated purified CD8+ T lymphocytes. It is also present on HUT-102, an HTLV- 1-infected T-lymphocyte line. Its ligand, gp34 (CD252 or Ox 40 Ligand encoded by TNFSF4), is found on some antigen presenting cells including B cells and dendritic cells as well as Epstein Barr virus (EBV)-transformed B lymphocytes. Preliminary evidence suggests a possible role for CD134 antigen in graft rejection.

757710 Rev. 2
Format Details
Down Arrow Up Arrow
RB744
The BD Horizon RealBlue™ 744 (RB744) Dye is part of the BD® family of blue dyes. It is a tandem fluorochrome with an excitation maximum (Ex Max) at 498-nm and an emission maximum (Em Max) at 746-nm as measured using an antibody-dye conjugate. Driven by BD® innovation, RB744 can be used on both spectral and conventional cytometers and is designed to be excited by the Blue laser (488-nm) with minimal excitation by the 561-nm Yellow-Green laser. For conventional instruments equipped with a Blue laser (488-nm), we recommend using an optical filter centered near 750-nm (e.g., a 750/60-nm bandpass filter).
altImg
RB744
Blue 488 nm
498 nm
746 nm
757710 Rev.2
Citations & References
Down Arrow Up Arrow
View product citations for antibody "757710" on CiteAb

Development References (5)

  1. Godfrey W, Buck D, Harara M, Benike C, Engleman E. Studies of the L106 protein and its gene: Evidence that L106 and Ox 40 are homologous. In: Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995:1157-1160.
  2. Godfrey WR, Fagnoni FF, Harara MA, Buck D, Engleman EG. Identification of a human OX-40 ligand, a costimulator of CD4+ T cells with homology to tumor necrosis factor. J Exp Med. 1994 August; 180(2):757-762. (Clone-specific: Flow cytometry). View Reference
  3. Lamb LS, Abhyankar SA, Hazlett L, et al. Expression of CD134 (0X-40) on T cells during the first 100 days following allogeneic bone marrow transplantation as a marker for lymphocyte activation and therapy-resistant graft-versus-host disease.. Cytometry. 1999; 38(5):238-43. (Biology). View Reference
  4. Mallett S, Fossum S, Barclay AN. Characterization of the MRC OX40 antigen of activated CD4 positive T lymphocytes--a molecule related to nerve growth factor receptor. EMBO J. 1990; 9(4):1063-1068. (Biology). View Reference
  5. Paterson DJ, Jefferies WA, Green JR. Antigens of activated rat T lymphocytes including a molecule of 50,000 Mr detected only on CD4 positive T blasts. Mol Immunol. 1987; 24(12):1281-1290. (Biology). View Reference
View All (5) View Less
757710 Rev. 2

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.