Skip to main content Skip to navigation
R718 Rat Anti-Human IL-2
R718 Rat Anti-Human IL-2
Two color flow cytometric analysis of IL-2 expression in activated human peripheral blood lymphocytes. Human peripheral blood mononuclear cells were stimulated for 5 h with Phorbol 12-Myristate 13-Acetate (PMA, Sigma P-8139; 50 ng/ml) and Calcium Ionophore A23187 (Sigma C-9275; 1 μ g/ml), in the presence of BD GolgiStop™ Protein Transport Inhibitor (containing Monensin) (Cat. No. 554724). The cells were fixed with BD Cytofix™ Fixation Buffer (Cat. No. 554655), washed, permeabilized and stained in BD Perm/Wash™ Buffer (Cat. No. 554723) with PE Mouse Anti-Human CD3 antibody (Cat No. 555333/561808/561809) and either BD Horizon™ R718 Rat IgG2a, κ Isotype Control (Cat No. 566941, Left Plot) or BD Horizon R718 Rat Anti-Human IL-2 antibody (Cat No. 567057/567248, Right Plot) using BD Biosciences Intracellular Cytokine Staining Protocol. A bivariate pseudocolor density plots showing the correlated expression of IL-2 (or Ig Isotype control staining) versus CD3 was derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ software.
Two color flow cytometric analysis of IL-2 expression in activated human peripheral blood lymphocytes. Human peripheral blood mononuclear cells were stimulated for 5 h with Phorbol 12-Myristate 13-Acetate (PMA, Sigma P-8139; 50 ng/ml) and Calcium Ionophore A23187 (Sigma C-9275; 1 μ g/ml), in the presence of BD GolgiStop™ Protein Transport Inhibitor (containing Monensin) (Cat. No. 554724). The cells were fixed with BD Cytofix™ Fixation Buffer (Cat. No. 554655), washed, permeabilized and stained in BD Perm/Wash™ Buffer (Cat. No. 554723) with PE Mouse Anti-Human CD3 antibody (Cat No. 555333/561808/561809) and either BD Horizon™ R718 Rat IgG2a, κ Isotype Control (Cat No. 566941, Left Plot) or BD Horizon R718 Rat Anti-Human IL-2 antibody (Cat No. 567057/567248, Right Plot) using BD Biosciences Intracellular Cytokine Staining Protocol. A bivariate pseudocolor density plots showing the correlated expression of IL-2 (or Ig Isotype control staining) versus CD3 was derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ software.
Product Details
Down Arrow Up Arrow


BD Horizon™
IL2; Interleukin-2; T-cell growth factor; TCGF
Human (QC Testing), Rhesus, Cynomolgus, Baboon (Tested in Development)
Rat IgG2a, κ
Human IL-2 Recombinant Protein
Intracellular staining (flow cytometry) (Routinely Tested)
5 µl
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unreacted dye was removed.

Recommended Assay Procedures

BD™ CompBeads can be used as surrogates to assess fluorescence spillover (Compensation). When fluorochrome conjugated antibodies are bound to BD CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD CompBead to ensure that BD CompBeads are appropriate for your specific cellular application.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  5. This product is provided under an Agreement between BIOTIUM and BD Biosciences. This product, and only in the amount purchased by buyer, may be used solely for buyer’s own internal research, in a manner consistent with the accompanying product literature. No other right to use, sell or otherwise transfer (a) this product, or (b) its components is hereby granted expressly, by implication or by estoppel. This product is for research use only. Diagnostic uses require a separate license from Biotium, Inc. For information on purchasing a license to this product including for purposes other than research, contact Biotium, Inc., 3159 Corporate Place, Hayward, CA 94545, Tel: (510) 265-1027. Fax: (510) 265-1352. Email: btinfo@biotium.com.
  6. Alexa Fluor™ is a trademark of Life Technologies Corporation.
  7. Species cross-reactivity detected in product development may not have been confirmed on every format and/or application.
  8. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
567248 Rev. 1
Antibody Details
Down Arrow Up Arrow
MQ1-17H12

The MQ1-17H12 monoclonal antibody specifically binds to the multifunctional cytokine, human Interleukin-2 (IL-2). IL-2 is produced by activated T cells and has multiple functions that can affect the growth, proliferation, differentiation and survival of many different target cell types including T cells, B cells, NK cells, monocytes and macrophages. The immunogen used to generate the MQ1-17H12 hybridoma was purified recombinant human IL-2 protein. The MQ1-17H12 antibody reportedly neutralizes the biological activity of human IL-2.

The antibody was conjugated to BD Horizon Red 718, which has been developed exclusively by for BD Biosciences as a better alternative to Alexa Fluor™ 700. BD Horizon Red 718 can be excited by the red laser (628 – 640 nm) and, with an Em Max around 718 nm, it can be detected using a 730/45 nm filter. Due to similar excitation and emission properties, we do not recommend using R718 in combination with APC-R700 or Alexa Fluor™ 700.

567248 Rev. 1
Format Details
Down Arrow Up Arrow
R718
The BD Horizon™ Red 718 (R718) Dye is part of the BD red family of dyes. It is a small organic fluorochrome with an excitation maximum (Ex Max) at 695-nm and an emission maximum (Em Max) at 718-nm. Driven by BD innovation, R718 is designed to be excited by the red laser (627–640-nm) and detected using an optical filter centered near 720-nm (e.g., a 720/40-nm bandpass filter). R718 is a brighter alternative to Alexa Fluor™ 700. R718 is also a bright small molecule alternative to APC-R700 with lower spread into the APC detector. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
R718
Red 627-640 nm
695 nm
718 nm
567248 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "567248" on CiteAb

Development References (3)

  1. Abrams J. Immunoenzymetric assay of mouse and human cytokines using NIP-labeled anti-cytokine antibodies. Curr Protoc Immunol. 2001; 1:6.20-6.21. (Clone-specific: ELISA). View Reference
  2. Abrams JS, Roncarolo MG, Yssel H, Andersson U, Gleich GJ, Silver JE. Strategies of anti-cytokine monoclonal antibody development: immunoassay of IL-10 and IL-5 in clinical samples. Immunol Rev. 1992; 127:5-24. (Clone-specific: Blocking, ELISA, Immunoprecipitation). View Reference
  3. Prussin C, Metcalfe DD. Detection of intracytoplasmic cytokine using flow cytometry and directly conjugated anti-cytokine antibodies. J Immunol Methods. 1995; 188(1):117-128. (Methodology: Flow cytometry). View Reference
567248 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.