Skip to main content Skip to navigation
R718 Mouse Anti-Human CD7
R718 Mouse Anti-Human CD7
Multiparameter flow cytometric analysis of CD7 expression on Human peripheral blood leucocytes. Human whole blood was stained with PE Mouse Anti-Human CD3 antibody (Cat. No. 555333) and with either BD Horizon™ R718 Mouse IgG2a, κ Isotype Control (Cat. No. 566949; Left Plots) or BD Horizon™ R718 Mouse Anti-Human CD7 antibody (Cat. No. 568384/568385; Right Plots). Erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202) after staining. The bivariate pseudocolor density plots showing the correlated expression of either CD7 (or Ig Isotype control staining) versus CD3 (Top Plots) or side light-scatter (SSC-A) signals (Bottom Plots) were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes (Top Plots) or leucocyte populations (Bottom Plots). Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software
Multiparameter flow cytometric analysis of CD7 expression on Human peripheral blood leucocytes. Human whole blood was stained with PE Mouse Anti-Human CD3 antibody (Cat. No. 555333) and with either BD Horizon™ R718 Mouse IgG2a, κ Isotype Control (Cat. No. 566949; Left Plots) or BD Horizon™ R718 Mouse Anti-Human CD7 antibody (Cat. No. 568384/568385; Right Plots). Erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202) after staining. The bivariate pseudocolor density plots showing the correlated expression of either CD7 (or Ig Isotype control staining) versus CD3 (Top Plots) or side light-scatter (SSC-A) signals (Bottom Plots) were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes (Top Plots) or leucocyte populations (Bottom Plots). Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software
Product Details
Down Arrow Up Arrow


BD Horizon™
LEU-9; T-cell leukemia antigen; T-cell surface antigen Leu-9
Human (QC Testing)
Mouse BALB/c IgG2a, κ
T-acute lymphoblastic leukemia cells
Flow cytometry (Routinely Tested)
5 µl
II T 31; III T 563; V NK12; VI T 6T-R7, T 6T-CD7.2, BP 494, BP 543
924
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unreacted dye was removed.

Recommended Assay Procedures

BD™ CompBeads can be used as surrogates to assess fluorescence spillover (Compensation). When fluorochrome conjugated antibodies are bound to BD CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD CompBead to ensure that BD CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  3. An isotype control should be used at the same concentration as the antibody of interest.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. This product is provided under an Agreement between BIOTIUM and BD Biosciences. This product, and only in the amount purchased by buyer, may be used solely for buyer’s own internal research, in a manner consistent with the accompanying product literature. No other right to use, sell or otherwise transfer (a) this product, or (b) its components is hereby granted expressly, by implication or by estoppel. This product is for research use only. Diagnostic uses require a separate license from Biotium, Inc. For information on purchasing a license to this product including for purposes other than research, contact Biotium, Inc., 3159 Corporate Place, Hayward, CA 94545, Tel: (510) 265-1027. Fax: (510) 265-1352. Email: btinfo@biotium.com.
  6. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  7. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  8. Alexa Fluor™ is a trademark of Life Technologies Corporation.
Antibody Details
Down Arrow Up Arrow
4H9

The 4H9 (Leu-9) monoclonal antibody specifically recognizes human CD7 which is also known as T-cell leukemia antigen, T-cell surface antigen Leu-9, and  LEU-9. CD7 is a ~40 kDa type I transmembrane glycoprotein that has an extracellular region with an N-terminal IgV-like domain followed by an extended O-glycosylated stalk region, a transmembrane region and cytoplasmic tail. The CD7 antigen is expressed throughout T-lymphocyte differentiation. It is present on 85% to 90% of peripheral blood T lymphocytes. In normal individuals, CD7 is expressed on all CD8+ lymphocytes, approximately 90% of CD4+ lymphocytes, and most NK cells. CD7 is weakly expressed on monocytes but not on granulocytes or B lymphocytes. It is expressed on hematopoietic progenitors and 50% of thymocytes. In leukemias, the CD7 antigen is present on the majority of T-lymphoid lineages. CD7 may function in cellular adhesion and play a role in interactions between T cells as well as T cells and B cells.

Format Details
Down Arrow Up Arrow
R718
The BD Horizon™ Red 718 (R718) Dye is part of the BD red family of dyes. It is a small organic fluorochrome with an excitation maximum (Ex Max) at 695-nm and an emission maximum (Em Max) at 718-nm. Driven by BD innovation, R718 is designed to be excited by the red laser (627–640-nm) and detected using an optical filter centered near 720-nm (e.g., a 720/40-nm bandpass filter). R718 is a brighter alternative to Alexa Fluor™ 700. R718 is also a bright small molecule alternative to APC-R700 with lower spread into the APC detector. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
R718
Red 627-640 nm
695 nm
718 nm
Citations & References
Down Arrow Up Arrow
View product citations for antibody "568385" on CiteAb

Development References (9)

  1. Foon KA, Todd RF. Immunologic classification of leukemia and lymphoma.. Blood. 1986; 68(1):1-31. (Clone-specific). View Reference
  2. Link M, Warnke R, Finlay J, et al. A single monoclonal antibody identifies T-cell lineage of childhood lymphoid malignancies.. Blood. 1983; 62(4):722-8. (Immunogen: Flow cytometry). View Reference
  3. Palker TJ, Scearce RM, Hensley LL, Ho W, Haynes BF. Comparison of the CD7 (3A1) group of T cell workshop antibodies. In: Reinherz EL, Haynes BF, Nadler LM, Bernstein ID, ed. Leukocyte Typing II. Human T Lymphocytes. New York, NY: Springer-Verlag; 1986:303-313.
  4. Picker LJ, Weiss LM, Medeiros LJ, Wood GS, Warnke RA. Immunophenotypic criteria for the diagnosis of non-Hodgkin's lymphoma.. Am J Pathol. 1987; 128(1):181-201. (Clone-specific: Immunohistochemistry). View Reference
  5. Rabinowich H, Pricop L, Herberman RB, Whiteside TL. Expression and function of CD7 molecule on human natural killer cells. J Immunol. 1994; 152(2):517-526. (Clone-specific: Flow cytometry). View Reference
  6. Weiss LM, Crabtree GS, Rouse RV, Warnke RA. Morphologic and immunologic characterization of 50 peripheral T-cell lymphomas.. Am J Pathol. 1985; 118(2):316-24. (Clone-specific: Immunohistochemistry). View Reference
  7. Weiss LM, Wood GS, Warnke RA. Immunophenotypic differences between dermatopathic lymphadenopathy and lymph node involvement in mycosis fungoides.. Am J Pathol. 1985; 120(2):179-85. (Clone-specific: Immunohistochemistry). View Reference
  8. Wood GS, Abel EA, Hoppe RT, Warnke RA. Leu-8 and Leu-9 antigen phenotypes: immunologic criteria for the distinction of mycosis fungoides from cutaneous inflammation.. J Am Acad Dermatol. 1986; 14(6):1006-13. (Clone-specific: Immunohistochemistry). View Reference
  9. Zola H, Swart B, Nicholson I, Voss E. CD7. In: Zola H. Leukocyte and stromal cell molecules : the CD markers. Hoboken, N.J.: Wiley-Liss; 2007:52.
View All (9) View Less

Please refer to Support Documents for Quality Certificates

 

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

 

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.