Skip to main content Skip to navigation
R718 Mouse Anti-Human CD61 (Integrin β3)

BD Horizon™ R718 Mouse Anti-Human CD61 (Integrin β3)

Clone VI-PL2 (also known as VIPL2) (RUO)

R718 Mouse Anti-Human CD61 (Integrin β3)

Flow cytometric analysis of CD61 (Integrin β3) expression on Human peripheral blood platelets.  Platelets were isolated from fresh Human whole blood and fixed with 2% formaldehyde. After washing, the fixed platelets were stained with either BD Horizon™ R718 Mouse IgG1, κ Isotype Control (Cat. No. 567470; dashed line histogram) or BD Horizon™ R718 Mouse Anti-Human CD61 (Integrin β3) antibody (Cat. No. 569595/569596; solid line histogram). The fluorescence histogram showing CD61(Integrin β3) expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of intact platelets. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ software.

Flow cytometric analysis of CD61 (Integrin β3) expression on Human peripheral blood platelets.  Platelets were isolated from fresh Human whole blood and fixed with 2% formaldehyde. After washing, the fixed platelets were stained with either BD Horizon™ R718 Mouse IgG1, κ Isotype Control (Cat. No. 567470; dashed line histogram) or BD Horizon™ R718 Mouse Anti-Human CD61 (Integrin β3) antibody (Cat. No. 569595/569596; solid line histogram). The fluorescence histogram showing CD61(Integrin β3) expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of intact platelets. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ software.

Product Details
Down Arrow Up Arrow


BD Horizon™
Integrin β3; Integrin beta-3; GP3A; GPIIIa; ITGB3; ITB3
Human (QC Testing), Rhesus,Cynomolgus,Baboon,Dog,Cow (Tested in Development)
Mouse IgG1, κ
Flow cytometry (Routinely Tested)
5 µl/test
III 866; IV P83; V T-124
3690
AB_3685166
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unreacted dye was removed.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  3. An isotype control should be used at the same concentration as the antibody of interest.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  6. Species cross-reactivity detected in product development may not have been confirmed on every format and/or application.
  7. This product is provided under an Agreement between BIOTIUM and BD Biosciences. This product, and only in the amount purchased by buyer, may be used solely for buyer’s own internal research, in a manner consistent with the accompanying product literature. No other right to use, sell or otherwise transfer (a) this product, or (b) its components is hereby granted expressly, by implication or by estoppel. This product is for research use only. Diagnostic uses require a separate license from Biotium, Inc. For information on purchasing a license to this product including for purposes other than research, contact Biotium, Inc., 3159 Corporate Place, Hayward, CA 94545, Tel: (510) 265-1027. Fax: (510) 265-1352. Email: btinfo@biotium.com.
  8. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  9. Alexa Fluor™ is a trademark of Life Technologies Corporation.
  10. For U.S. patents that may apply, see bd.com/patents.
569595 Rev. 1
Antibody Details
Down Arrow Up Arrow
VI-PL2

The VI-PL2 monoclonal antibody specifically binds to CD61. CD61 is a 105 kDa transmembrane glycoprotein that is also known as integrin β3 and platelet glycoprotein IIIa (GPIIIa or GP3A). It is expressed on platelets, megakaryocytes, osteoclasts and endothelia. Integrin β3 associates with gpIIa (CD41) to form the CD41/CD61 complex which mediates platelet adhesion and aggregation. CD61 also associates with CD51 to form the CD51/CD61 complex (vitronectin receptor). CD61 appears to bind to fibrinogen, fibronectin, vWF, vitronectin, and thrombospondin to mediate cell adhesion.

569595 Rev. 1
Format Details
Down Arrow Up Arrow
R718
The BD Horizon™ Red 718 (R718) Dye is part of the BD red family of dyes. It is a small organic fluorochrome with an excitation maximum (Ex Max) at 695-nm and an emission maximum (Em Max) at 718-nm. Driven by BD innovation, R718 is designed to be excited by the red laser (627–640-nm) and detected using an optical filter centered near 720-nm (e.g., a 720/40-nm bandpass filter). R718 is a brighter alternative to Alexa Fluor™ 700. R718 is also a bright small molecule alternative to APC-R700 with lower spread into the APC detector. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
R718
Red 627-640 nm
695 nm
718 nm
569595 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "569595" on CiteAb

Development References (6)

  1. Kishimoto T. Tadamitsu Kishimoto .. et al., ed. Leucocyte typing VI : white cell differentiation antigens : proceedings of the sixth international workshop and conference held in Kobe, Japan, 10-14 November 1996. New York: Garland Pub.; 1997.
  2. Knapp W, Dorken B, Rieber P, Schmidt RE, Stein H, von dem Borne AE. CD Antigens 1989: Summary of Nomenclature System for Human Leacocyte Surface Antigens. Am J Pathol. 1989; 135(2):420-421. (Clone-specific: Flow cytometry). View Reference
  3. Lin G-X, Yang X, Hollemweguer E, et al. Cross-reactivity of CD antibodies in eight animal species. In: Mason D. David Mason .. et al., ed. Leucocyte typing VII : white cell differentiation antigens : proceedings of the Seventh International Workshop and Conference held in Harrogate, United Kingdom. Oxford: Oxford University Press; 2002:519-523.
  4. Mason D. David Mason .. et al., ed. Leucocyte typing VII : white cell differentiation antigens : proceedings of the Seventh International Workshop and Conference held in Harrogate, United Kingdom. Oxford: Oxford University Press; 2002.
  5. Modderman PW. Cluster report: CD61. In: Knapp W. W. Knapp .. et al., ed. Leucocyte typing IV : white cell differentiation antigens. Oxford New York: Oxford University Press; 1989:1025.
  6. Yu J-F, Yang X-F, Nguyen E, et al. Seventh HLDA Workshop—Cytokine Receptor Section: Flow cytometric analysis on 11 different target cells. In: Mason D. David Mason .. et al., ed. Leucocyte typing VII : white cell differentiation antigens : proceedings of the Seventh International Workshop and Conference held in Harrogate, United Kingdom. Oxford: Oxford University Press; 2002:275-278.
View All (6) View Less
569595 Rev. 1

Please refer to Support Documents for Quality Certificates

 

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

 

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.