BB700 Mouse Anti-Human ErbB3 (HER-3)
Product Details
Down Arrow Up Arrow


BD OptiBuild™
ERBB3; ErbB-3; HER3; c-erbB-3; c-erbB3; human epidermal growth factor receptor 3; receptor tyrosine-protein kinase erbB-3
Human (Tested in Development)
Mouse BALB/c IgG1, κ
Human cEerbB3 Recombinant Protein
Flow cytometry (Qualified)
0.2 mg/ml
AB_2875771
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

BD™ CompBeads can be used as surrogates to assess fluorescence spillover (Compensation).  When fluorochrome conjugated antibodies are bound to CompBeads, they have spectral properties very similar to cells.   However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls.  It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and CompBead to ensure that BD Comp beads are appropriate for your specific cellular application.

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes are used in the same experiment. Fluorescent dye interactions may cause staining artifacts which may affect data interpretation. The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).

For optimal results, it is recommended to perform two washes after staining with antibodies. Cells may be prepared, stained with antibodies and washed twice with wash buffer per established protocols for immunofluorescent staining prior to acquisition on a flow cytometer. Performing fewer than the recommended wash steps may lead to increased spread of the negative population.

Product Notices

  1. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  2. Researchers should determine the optimal concentration of this reagent for their individual applications.
  3. An isotype control should be used at the same concentration as the antibody of interest.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  7. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  8. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  9. BD Horizon Brilliant Blue 700 is covered by one or more of the following US patents: 8,455,613 and 8,575,303.
  10. Cy is a trademark of GE Healthcare.
751796 Rev. 1
Antibody Details
Down Arrow Up Arrow
SGP1

The SGP1 monoclonal antibody specifically recognizes human ErbB3 (also known as HER-3), a 160-kDa glycoprotein that is a member of the epidermal growth factor receptor or ErbB family of receptor tyrosine kinases. Other members of the family include the epidermal growth factor receptor (EGFR, ErbB-1, HER1), ErbB-2 (Neu, HER2), and ErbB-4 (HER4). Members of this receptor family mediate the proliferation and differentiation of normal cells. They have a common structure consisting of an extracellular ligand-binding domain, a transmembrane region, and a cytoplasmic region that has sequence homology to tyrosine kinases, which is inactive in ErbB3. ErbB3 is expressed on neurons and in tissues from the digestive, urinary and respiratory tracts, the circulatory system, and female and male reproductive organs. It is overexpressed in a variety of tumors and is undetectable in hematopoietic tissue and cell lines derived from hematopoietic tumors. ErbB3 is able to form heterodimers with other ErbB family members that have active tyrosine kinases. This interaction is able to mediate signal transduction upon binding of ErbB3 to its ligand neuregulin, a cell adhesion molecule that is involved in development of the heart and nervous system.

The antibody was conjugated to BD Horizon BB700, which is part of the BD Horizon Brilliant™ Blue family of dyes.   It is a polymer-based tandem dye developed exclusively by BD Biosciences.  With an excitation max of 485 nm and an emission max of 693 nm, BD Horizon BB700 can be excited by the 488 nm laser and detected in a standard PerCP-Cy™5.5 set (eg, 695/40-nm filter). This dye provides a much brighter alternative to PerCP-Cy5.5 with less cross laser excitation off the 405 nm and 355 nm lasers.

751796 Rev. 1
Format Details
Down Arrow Up Arrow
BB700
The BD Horizon Brilliant™ Blue 700 (BB700) Dye is part of the BD Horizon Brilliant™ Blue family of dyes. This tandem fluorochrome is comprised of a polymer-technology dye donor with an excitation maximum (Ex Max) of 476-nm and an acceptor dye with an emission maximum (Em Max) at 695-nm. Driven by BD innovation, BB700 is designed to be excited by the blue laser (488-nm) and detected using an optical filter centered near 695-nm (e.g., a 695/20-nm bandpass filter). The donor dye can be excited by the Violet (405 nm) laser and the acceptor dye can be excited by the red (627–640 nm) laser resulting in cross-laser excitation and fluorescence spillover. BB700 Reagents are significantly brighter than equivalent PerCP or PerCP-Cy5.5 reagents and are less sensitive to photobleaching. In addition, BB700 shows much less excitation by the violet (407-nm) laser resulting in less spillover. BB700 has minimal yellow green (562-nm) excitation and is ideal for instruments with both blue (488-nm) and yellow green (562-nm) lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BB700
Blue 488 nm
476 nm
695 nm
751796 Rev.1
Citations & References
Down Arrow Up Arrow

Development References (4)

  1. Münster PN, Marchion DC, Basso AD, Rosen N. Degradation of HER2 by ansamycins induces growth arrest and apoptosis in cells with HER2 overexpression via a HER3, phosphatidylinositol 3'-kinase-AKT-dependent pathway.. Cancer Res. 2002; 62(11):3132-7. (Biology). View Reference
  2. Rajkumar T, Gullick WJ. A monoclonal antibody to the human c-erbB3 protein stimulates the anchorage-independent growth of breast cancer cell lines.. Br J Cancer. 1994; 70(3):459-65. (Clone-specific: Flow cytometry, Functional assay). View Reference
  3. Rajkumar T1, Majhi U, Malligarjuna V, Gullick W.. Prevalence of C-erbb3 expression in squamous-cell carcinomas of the cervix as determined by the monoclonal-antibody rtj2.. Int J Oncol. 1995; 6(1):105-109. (Immunogen: Immunohistochemistry, Immunoprecipitation, Western blot). View Reference
  4. Wang H, Jin Y, Reddy MV, et al. Genetically dependent ERBB3 expression modulates antigen presenting cell function and type 1 diabetes risk.. PLoS ONE. 2010; 5(7):e11789. (Biology: Flow cytometry). View Reference
View All (4) View Less
751796 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.