Skip to main content Skip to navigation
APC Streptavidin
Product Details
Down Arrow Up Arrow


BD™
Flow cytometry
20 μL
Phosphate buffered saline with gelatin and 0.1% sodium azide.
RUO (GMP)


Preparation And Storage

Store vials at 2°C to 8°C. Conjugated forms should not be frozen and should be protected from exposure to light. Each reagent is stable for the period shown on the bottle label when stored as directed.

349024 Rev. 1
Antibody Details
Down Arrow Up Arrow

Streptavidin is prepared chromatographically from Streptomyces avidinii.

349024 Rev. 1
Format Details
Down Arrow Up Arrow
APC
Allophycocyanin (APC), is part of the BD family of phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 651 nm and an emission maximum (Em Max) at 660 nm. APC is designed to be excited by the Red (627-640 nm) laser and detected using an optical filter centered near 660 nm (e.g., a 660/20 nm bandpass filter). Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
APC
Red 627-640 nm
651 nm
660 nm
349024 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "349024" on CiteAb

Development References (5)

  1. Centers for Disease Control. Update: universal precautions for prevention of transmission of human immunodeficiency virus, hepatitis B virus, and other bloodborne pathogens in healthcare settings. MMWR. 1988; 37:377-388. (Biology).
  2. Clinical and Laboratory Standards Institute. 2005. (Biology).
  3. Green NM. Avidin. Adv Protein Chem. 1975; 29:85-133. (Biology).
  4. Loken MR, Keij JF, Kelley KA. Comparison of helium-neon and dye lasers for the excitation of allophycocyanin. Cytometry. 1987; 8:96-100. (Biology).
  5. Shapiro HM, Glazer AN, Christenson L, Williams JM, Strom TB. Immunofluorescence measurement in a flow cytometer using low-power helium-neon laser excitation. Cytometry. 1983; 4:276-279. (Biology).
View All (5) View Less
349024 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures. 

 

Although not required, these products are manufactured in accordance with Good Manufacturing Practices.