Skip to main content Skip to navigation
RB780 Mouse Anti-Human ERBB3
Product Details
Down Arrow Up Arrow


BD OptiBuild™
ERBB3; ErbB-3; HER3; c-erbB-3; c-erbB3; human epidermal growth factor receptor 3; receptor tyrosine-protein kinase erbB-3
Human (Tested in Development)
Mouse BALB/c IgG1, κ
Human cEerbB3 Recombinant Protein
Flow cytometry (Qualified)
0.2 mg/ml
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. When using high concentrations of antibody, background binding of this dye to erythroid fragments produced by ammonium chloride-based lysis, such as with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899), has been observed when the antibody conjugate was present during the lysis procedure. This may cause nonspecific staining of target cells, such as leukocytes, which have bound the resulting erythroid fragments. This background can be mitigated by any of the following: titrating the antibody conjugate to a lower concentration, fixing samples with formaldehyde, or removing erythrocytes before staining (eg, gradient centrifugation or pre-lysis with wash). This background has not been observed when cells were lysed with BD FACS™ Lysing Solution (Cat. No. 349202) after staining.
  2. Researchers should determine the optimal concentration of this reagent for their individual applications.
  3. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  4. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  5. Please observe the following precautions: Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
  6. An isotype control should be used at the same concentration as the antibody of interest.
  7. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  8. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  9. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  10. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  11. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.
  12. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
755490 Rev. 1
Antibody Details
Down Arrow Up Arrow
SGP1

The SGP1 monoclonal antibody specifically recognizes human ErbB3 (also known as HER-3), a 160-kDa glycoprotein that is a member of the epidermal growth factor receptor or ErbB family of receptor tyrosine kinases. Other members of the family include the epidermal growth factor receptor (EGFR, ErbB-1, HER1), ErbB-2 (Neu, HER2), and ErbB-4 (HER4). Members of this receptor family mediate the proliferation and differentiation of normal cells. They have a common structure consisting of an extracellular ligand-binding domain, a transmembrane region, and a cytoplasmic region that has sequence homology to tyrosine kinases, which is inactive in ErbB3. ErbB3 is expressed on neurons and in tissues from the digestive, urinary and respiratory tracts, the circulatory system, and female and male reproductive organs. It is overexpressed in a variety of tumors and is undetectable in hematopoietic tissue and cell lines derived from hematopoietic tumors. ErbB3 is able to form heterodimers with other ErbB family members that have active tyrosine kinases. This interaction is able to mediate signal transduction upon binding of ErbB3 to its ligand neuregulin, a cell adhesion molecule that is involved in development of the heart and nervous system.

755490 Rev. 1
Format Details
Down Arrow Up Arrow
RB780
The BD Horizon RealBlue™ 780 (RB780) Dye is part of the BD family of blue dyes. It is a tandem fluorochrome with an excitation maximum (Ex Max) at 498-nm and an emission maximum (Em Max) at 781-nm. Driven by BD innovation, RB780 can be used on both spectral and conventional cytometers and is designed to be excited by the Blue laser (488-nm) with minimal excitation by the 561-nm Yellow-Green laser. For conventional instruments equipped with a Blue laser (488-nm), RB780 can be used as an alternative to PE-Cy7 and we recommend using an optical filter centered near 780-nm (eg, a 780/60-nm bandpass filter). For spectral instruments equipped with a Blue laser (488-nm), it can be used in conjunction with PE-Cy7. RB780 is on average brighter than PE-Cy7 and has minimal spillover into Yellow-Green detectors.
altImg
RB780
Blue 488 nm
498 nm
781 nm
755490 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "755490" on CiteAb

Development References (4)

  1. Münster PN, Marchion DC, Basso AD, Rosen N. Degradation of HER2 by ansamycins induces growth arrest and apoptosis in cells with HER2 overexpression via a HER3, phosphatidylinositol 3'-kinase-AKT-dependent pathway.. Cancer Res. 2002; 62(11):3132-7. (Biology). View Reference
  2. Rajkumar T, Gullick WJ. A monoclonal antibody to the human c-erbB3 protein stimulates the anchorage-independent growth of breast cancer cell lines.. Br J Cancer. 1994; 70(3):459-65. (Clone-specific: Flow cytometry, Functional assay). View Reference
  3. Rajkumar T1, Majhi U, Malligarjuna V, Gullick W.. Prevalence of C-erbb3 expression in squamous-cell carcinomas of the cervix as determined by the monoclonal-antibody rtj2.. Int J Oncol. 1995; 6(1):105-109. (Immunogen: Immunohistochemistry, Immunoprecipitation, Western blot). View Reference
  4. Wang H, Jin Y, Reddy MV, et al. Genetically dependent ERBB3 expression modulates antigen presenting cell function and type 1 diabetes risk.. PLoS ONE. 2010; 5(7):e11789. (Biology: Flow cytometry). View Reference
View All (4) View Less
755490 Rev. 1

Please refer to Support Documents for Quality Certificates

 

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

 

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.