RB780 Mouse Anti-Human CD133 (Prominin-1)
Product Details
Down Arrow Up Arrow


BD OptiBuild™
PROM1; PROML1; prominin-1; AC133; CORD12; MCDR2; MSTP061; RP41; STGD4
Human (Tested in Development)
Mouse BALB/c IgG2b, κ
Human full-length CD133 Transfected Cell Line
Flow cytometry (Qualified)
0.2 mg/ml
8842
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. When using high concentrations of antibody, background binding of this dye to erythroid fragments produced by ammonium chloride-based lysis, such as with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899), has been observed when the antibody conjugate was present during the lysis procedure. This may cause nonspecific staining of target cells, such as leukocytes, which have bound the resulting erythroid fragments. This background can be mitigated by any of the following: titrating the antibody conjugate to a lower concentration, fixing samples with formaldehyde, or removing erythrocytes before staining (eg, gradient centrifugation or pre-lysis with wash). This background has not been observed when cells were lysed with BD FACS™ Lysing Solution (Cat. No. 349202) after staining.
  2. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  3. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  4. An isotype control should be used at the same concentration as the antibody of interest.
  5. Researchers should determine the optimal concentration of this reagent for their individual applications.
  6. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  7. Please observe the following precautions: Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
  8. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  9. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  10. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  11. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
755327 Rev. 1
Antibody Details
Down Arrow Up Arrow
293C3

The 293C3 monoclonal antibody specifically recognizes CD133 which is also known as Prominin-like protein 1 (PROML1), Prominin-1 (PROM1), hProminin, Hematopoietic stem cell antigen, Macular dystrophy retinal 2 (MCDR2), Stargardt disease 4 autosomal dominant (STGD4), or AC133 antigen. CD133 is an ~120 kDa five-transmembrane, glycoprotein that is encoded by PROM1 (Prominin 1) which belongs to the Prominin gene family. This single-chain, pentaspan transmembrane glycoprotein is comprised of an extracellular N-terminus with two short intracellular sequences and two long extracellular loops followed by an intracellular C-terminus. CD133 is expressed on some cells found in different tissues including the bone marrow, cord and peripheral blood, placenta, liver, pancreas, kidney, lung, retina, brain and heart. It is expressed on a variety of cell types including hematopoietic stem cells and progenitor cells, neural stem cells, developing epithelial cells, precursor endothelial cells, and retinal cells. CD133 is expressed on some cancer cells found in leukemias, melanoma and retinoblastoma. It may serve as a cancer stem cell marker in a number of brain tumors, melanoma, colon cancer, hepatocellular carcinoma, pancreatic adenocarcinoma, and prostate cancer. A mutation in PROM1 has been associated with a form of human retinal degeneration. The 293C3 antibody recognizes a different epitope than the human CD133-specific W6B3C1 antibody.

755327 Rev. 1
Format Details
Down Arrow Up Arrow
RB780
The BD Horizon RealBlue™ 780 (RB780) Dye is part of the BD family of blue dyes. It is a tandem fluorochrome with an excitation maximum (Ex Max) at 498-nm and an emission maximum (Em Max) at 781-nm. Driven by BD innovation, RB780 can be used on both spectral and conventional cytometers and is designed to be excited by the Blue laser (488-nm) with minimal excitation by the 561-nm Yellow-Green laser. For conventional instruments equipped with a Blue laser (488-nm), RB780 can be used as an alternative to PE-Cy7 and we recommend using an optical filter centered near 780-nm (eg, a 780/60-nm bandpass filter). For spectral instruments equipped with a Blue laser (488-nm), it can be used in conjunction with PE-Cy7. RB780 is on average brighter than PE-Cy7 and has minimal spillover into Yellow-Green detectors.
altImg
RB780
Blue 488 nm
498 nm
781 nm
755327 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "755327" on CiteAb

Development References (5)

  1. Bühring HK, Marzer A, Lammers R, Wissinger B. CD133 cluster report. In: Mason D. David Mason .. et al., ed. Leucocyte typing VII : white cell differentiation antigens : proceedings of the Seventh International Workshop and Conference held in Harrogate, United Kingdom. Oxford: Oxford University Press; 2002:622-623.
  2. Koerner SP, André MC, Leibold JS, et al. An Fc-optimized CD133 antibody for induction of NK cell reactivity against myeloid leukemia.. Leukemia. 2017; 31(2):459-469. (Clone-specific: Blocking, Flow cytometry). View Reference
  3. Lammers R, Giesert C, Grünebach F, Marxer A, Vogel W, Bühring HJ. Monoclonal antibody 9C4 recognizes epithelial cellular adhesion molecule, a cell surface antigen expressed in early steps of erythropoiesis.. Exp Hematol. 2002; 30(6):537-45. (Immunogen: Flow cytometry). View Reference
  4. Maw MA, Corbeil D, Koch J, et al. A frameshift mutation in prominin (mouse)-like 1 causes human retinal degeneration.. Hum Mol Genet. 2000; 9(1):27-34. (Biology). View Reference
  5. Miraglia SJ, Buck D. CD133 (AC133). In: Mason D. David Mason .. et al., ed. Leucocyte typing VII : white cell differentiation antigens : proceedings of the Seventh International Workshop and Conference held in Harrogate, United Kingdom. Oxford: Oxford University Press; 2002:870-872.
View All (5) View Less
755327 Rev. 1

Please refer to Support Documents for Quality Certificates

 

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

 

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.