RB744 Mouse Anti-Human CD141
RB744 Mouse Anti-Human CD141
Multiparameter flow cytometric analysis using BD OptiBuild™ RB744 Mouse Anti-Human CD141 antibody (Cat. No. 757794; Right Plot) on Human peripheral blood, with corresponding IgG Isotype Control (Cat. No. 570519; Left Plot). Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer.
RB744 Mouse Anti-Human CD141
Multiparameter flow cytometric analysis using BD OptiBuild™ RB744 Mouse Anti-Human CD141 antibody (Cat. No. 757794; Right Plot) on Human peripheral blood, with corresponding IgG Isotype Control (Cat. No. 570519; Left Plot). Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer.
Multiparameter flow cytometric analysis using BD OptiBuild™ RB744 Mouse Anti-Human CD141 antibody (Cat. No. 757794; Right Plot) on Human peripheral blood, with corresponding IgG Isotype Control (Cat. No. 570519; Left Plot). Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer.
Multiparameter flow cytometric analysis using BD OptiBuild™ RB744 Mouse Anti-Human CD141 antibody (Cat. No. 757794; Right Plot) on Human peripheral blood, with corresponding IgG Isotype Control (Cat. No. 570519; Left Plot). Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer.
Product Details
Down Arrow Up Arrow


BD OptiBuild™
Thrombomodulin; TM; THBD; THRM; AHUS6; Fetomodulin; BDCA-3
Human (Tested in Development)
Mouse BALB/c IgG1, κ
Purified Human Thrombomodulin
Flow cytometry (Qualified)
0.2 mg/ml
VI E013
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. When using high concentrations of antibody, background binding of this dye to erythroid fragments produced by ammonium chloride-based lysis, such as with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899), has been observed when the antibody conjugate was present during the lysis procedure. This may cause nonspecific staining of target cells, such as leukocytes, which have bound the resulting erythroid fragments. This background can be mitigated by any of the following: titrating the antibody conjugate to a lower concentration, fixing samples with formaldehyde, or removing erythrocytes before staining (eg, gradient centrifugation or pre-lysis with wash). This background has not been observed when cells were lysed with BD FACS™ Lysing Solution (Cat. No. 349202) after staining.
  2. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  3. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  4. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  5. An isotype control should be used at the same concentration as the antibody of interest.
  6. Please observe the following precautions: We recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to protect exposure of conjugated reagents, including cells stained with those reagents, to any room illumination. Absorption of visible light can significantly affect the emission spectra and quantum yield of tandem fluorochrome conjugates.
  7. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  8. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  9. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  10. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  11. For U.S. patents that may apply, see bd.com/patents.
757794 Rev. 1
Antibody Details
Down Arrow Up Arrow
1A4

The 1A4 monoclonal antibody specifically binds to CD141. CD141 is a 75 kDa, single chain, type I membrane glycoprotein referred to as thrombomodulin and fetomodulin. CD141 is expressed on endothelial cells, smooth muscle cells, epithelial cells, synovial lining cells, and keratinocytes. It is also found on megakaryocytes, dendritic cells, peripheral blood monocytes, and neutrophils, but not on lymphocytes. Reports indicate that CD141 plays an important role in Protein C activation and the initiation of the Protein C anticoagulant pathway. Thrombin loses its procoagulant function when it binds to CD141, and the CD141/thrombin complex is able to activate Protein C.

757794 Rev. 1
Format Details
Down Arrow Up Arrow
RB744
The BD Horizon RealBlue™ 744 (RB744) Dye is part of the BD® family of blue dyes. It is a tandem fluorochrome with an excitation maximum (Ex Max) at 498-nm and an emission maximum (Em Max) at 746-nm as measured using an antibody-dye conjugate. Driven by BD® innovation, RB744 can be used on both spectral and conventional cytometers and is designed to be excited by the Blue laser (488-nm) with minimal excitation by the 561-nm Yellow-Green laser. For conventional instruments equipped with a Blue laser (488-nm), we recommend using an optical filter centered near 750-nm (e.g., a 750/60-nm bandpass filter).
altImg
RB744
Blue 488 nm
498 nm
746 nm
757794 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "757794" on CiteAb

Development References (4)

  1. Baracho GV, Kara N, Rigaud S, Lo E, Widmann SJ, Tyznik AJ. Functional phenotyping of circulating human cytotoxic T cells and NK cells using a 16-color flow cytometry panel.. STAR Protoc. 2022; 3(1):101069. (Clone-specific: Cytotoxicity, Flow cytometry, Functional assay). View Reference
  2. Chu M, Bird P. CD141 (thrombomodulin) Workshop Panel report. In: Kishimoto T. Tadamitsu Kishimoto .. et al., ed. Leucocyte typing VI : white cell differentiation antigens : proceedings of the sixth international workshop and conference held in Kobe, Japan, 10-14 November 1996. New York: Garland Pub.; 1997:741-742.
  3. Kishimoto T. Tadamitsu Kishimoto .. et al., ed. Leucocyte typing VI : white cell differentiation antigens : proceedings of the sixth international workshop and conference held in Kobe, Japan, 10-14 November 1996. New York: Garland Pub.; 1997.
  4. Teasdale MS, Bird CH, Bird P. Internalization of the anticoagulant thrombomodulin is constitutive and does not require a signal in the cytoplasmic domain. Immunol Cell Biol. 1994; 72(6):480-488. (Immunogen: Immunofluorescence, Immunoprecipitation, Western blot). View Reference
View All (4) View Less
757794 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.