Skip to main content Skip to navigation
PE-CF594 Rat Anti-Mouse CD304
PE-CF594 Rat Anti-Mouse CD304
Multicolor flow cytometric analysis of CD304 expression on mouse splenic lymphocytes. Balb/c mouse splenocytes were stained with BD Horizon™ BUV395 Rat Anti-Mouse CD4 (Cat. No. 563790/565974), and BD Horizon™ PE-CF594 Rat IgG2a, κ Isotype Control (Cat. No. 562302; Left Plot) or BD Horizon™ PE-CF594 Rat Anti-Mouse CD304 antibody (Cat. No. 567835; Right Plot) at 1.0 μg/test. 7-AAD (7-Amino-Actinomycin D) Solution (Cat. No. 559925) was added to the cells right before analysis. Bivariate pseudocolor density plots showing correlated expression of CD304 (or Ig Isotype control) versus CD4 staining were derived from gated events with the forward and side light-scatter characteristics of viable (7-AAD-negative) lymphocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
Multicolor flow cytometric analysis of CD304 expression on mouse splenic lymphocytes. Balb/c mouse splenocytes were stained with BD Horizon™ BUV395 Rat Anti-Mouse CD4 (Cat. No. 563790/565974), and BD Horizon™ PE-CF594 Rat IgG2a, κ Isotype Control (Cat. No. 562302; Left Plot) or BD Horizon™ PE-CF594 Rat Anti-Mouse CD304 antibody (Cat. No. 567835; Right Plot) at 1.0 μg/test. 7-AAD (7-Amino-Actinomycin D) Solution (Cat. No. 559925) was added to the cells right before analysis. Bivariate pseudocolor density plots showing correlated expression of CD304 (or Ig Isotype control) versus CD4 staining were derived from gated events with the forward and side light-scatter characteristics of viable (7-AAD-negative) lymphocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
Product Details
Down Arrow Up Arrow


BD Horizon™
neuropilin-1; Nrp1; A5 protein; NP-1; NPN-1; Npn1; Nrp
Mouse (QC Testing)
Rat WI, also known as Wistar (outbred) IgG2a, κ
Mouse CD304 Recombinant Protein
Flow cytometry (Routinely Tested)
0.2 mg/ml
18186
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unconjugated antibody and free dye were removed.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (Compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells.  However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Please observe the following precautions: Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
  3. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. An isotype control should be used at the same concentration as the antibody of interest.
  8. When excited by the yellow-green (561-nm) laser, the fluorescence may be brighter than when excited by the blue (488-nm) laser.
  9. Because of the broad absorption spectrum of the tandem fluorochrome, extra care must be taken when using multi-laser cytometers, which may directly excite both PE and CF™594.
  10. CF™ is a trademark of Biotium, Inc.
  11. This product is provided under an Agreement between BIOTIUM and BD Biosciences. The manufacture, use, sale, offer for sale, or import of this product is subject to one or more patents or pending applications owned or licensed by Biotium, Inc. This product, and only in the amount purchased by buyer, may be used solely for buyer’s own internal research, in a manner consistent with the accompanying product literature. No other right to use, sell or otherwise transfer (a) this product, or (b) its components is hereby granted expressly, by implication or by estoppel. This product is for research use only. Diagnostic uses require a separate license from Biotium, Inc. For information on purchasing a license to this product including for purposes other than research, contact Biotium, Inc., 3159 Corporate Place, Hayward, CA 94545, Tel: (510) 265-1027. Fax: (510) 265-1352. Email: btinfo@biotium.com.
  12. Texas Red is a registered trademark of Molecular Probes, Inc., Eugene, OR.
  13. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
567835 Rev. 1
Antibody Details
Down Arrow Up Arrow
V46-1954

The V46-1954 monoclonal antibody specifically recognizes mouse CD304, also known as neuropilin 1 (Nrp1). It does not cross-react with neuropilin 2 (Nrp2). CD304 is a type-1 transmembrane protein that plays important roles in neuronal development, angiogenesis, and immunosuppression. Through interactions with plexins and VEGF receptors on neurons and endothelial cells, it is a co-receptor for the class III semaphorin subfamily and vascular endothelial growth factor (VEGF), respectively. The ability of the S1 protein of SARS-CoV-2 virus to bind to Nrp1, a potential mechanism for cellular infection, is being investigated. In the immune system, CD304 is expressed on natural (thymus-derived) Treg cells and may be responsible for the unsuccessful immune regulation of tumor growth.

This antibody is conjugated to BD Horizon™ PE-CF594, which has been developed exclusively by BD Biosciences as a better alternative to PE-Texas Red®. PE-CF594 excites and emits at similar wavelengths to PE-Texas Red® yet exhibits improved brightness and spectral characteristics. Due to PE having maximal absorption peaks at 496 nm and 564 nm, PE-CF594 can be excited by the blue (488-nm), green (532-nm) and yellow-green (561-nm) lasers and can be detected with the same filter set as PE-Texas Red® (eg, 610/20-nm filter).

567835 Rev. 1
Format Details
Down Arrow Up Arrow
PE-CF594
BD Horizon™ PE-CF594 dye is a part of the BD PE family of dyes. This tandem fluorochrome is comprised of a R-Phycoerythrin (PE) donor that has excitation maxima (Ex Max) of 496-nm and 566-nm and an acceptor dye with an emission maximum (Em Max) at 615-nm. PE-CF594, driven by BD innovation, is designed to be excited by the blue (488-nm), Green (532-nm) and yellow-green (561-nm) lasers and detected using an optical filter centered near 615 nm (e.g., a 610/20-nm bandpass filter). The donor dye can be excited by the Blue (488-nm), Green (532-nm) and yellow-green (561-nm) lasers and the acceptor dye can be excited by the green (532-nm) laser resulting in cross-laser excitation and fluorescence spillover. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE-CF594
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
615 nm
567835 Rev.1
Citations & References
Down Arrow Up Arrow

Development References (9)

  1. Delgoffe GM, Woo SR, Turnis ME, et al. Stability and function of regulatory T cells is maintained by a neuropilin-1-semaphorin-4a axis.. Nature. 2013; 501(7466):252-6. (Biology). View Reference
  2. Goel HL, Mercurio AM. VEGF targets the tumour cell.. Nat Rev Cancer. 2013; 13(12):871-82. (Biology). View Reference
  3. Guo HF, Vander Kooi CW. Neuropilin Functions as an Essential Cell Surface Receptor.. J Biol Chem. 2015; 290(49):29120-6. (Biology). View Reference
  4. Hansen W, Hutzler M, Abel S, et al. Neuropilin 1 deficiency on CD4+Foxp3+ regulatory T cells impairs mouse melanoma growth.. J Exp Med. 2012; 209(11):2001-16. (Biology). View Reference
  5. Hwang JY, Sun Y, Carroll CR, Usherwood EJ. Neuropilin-1 Regulates the Secondary CD8 T Cell Response to Virus Infection. mSphere. 2019; 4(3):e00221-19. (Biology). View Reference
  6. James L. Daly, Boris Simonetti, Carlos Antón-Págaro, et al. Neuropilin-1 is a host factor for SARS-CoV-2 infection. 2020. Available: https://doi.org/10.1101/2020.06.05.134114 2020, June 6.
  7. Liu WQ, Lepelletier Y, Montès M, et al. NRPa-308, a new neuropilin-1 antagonist, exerts in vitro anti-angiogenic and anti-proliferative effects and in vivo anti-cancer effects in a mouse xenograft model.. Cancer Lett. 2018; 414:88-98. (Biology). View Reference
  8. Roy S, Bag AK, Singh RK, Talmadge JE, Batra SK, Datta K. Multifaceted Role of Neuropilins in the Immune System: Potential Targets for Immunotherapy.. Front Immunol. 2017; 8:1228. (Biology). View Reference
  9. Yadav M, Louvet C, Davini D, et al. Neuropilin-1 distinguishes natural and inducible regulatory T cells among regulatory T cell subsets in vivo.. J Exp Med. 2012; 209(10):1713-22, S1-19. (Biology). View Reference
View All (9) View Less
567835 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.