Alexa Fluor® 647 Mouse anti-Human CD110
Alexa Fluor® 647 Mouse anti-Human CD110
Flow cytometric analysis of human CD110 expression on platelets and HEL92.1.7 cells. Human platelets (Left Panel) and HEL92.1.7 cells (Right Panel) were stained with either Alexa Fluor® 647 Mouse IgG2b, κ Isotype Control (Cat. No. 557903; dashed line histogram) or Alexa Fluor® 647 Mouse Anti-Human CD110 antibody (Cat. No. 562188; solid line histogram). Flow cytometric fluorescence histograms were derived from gated events with the forward and side light-scatter characteristics of platelets or viable HEL92.1.7 cells. Flow cytometry was performed using a BD™ LSR II Flow Cytometer System.
Flow cytometric analysis of human CD110 expression on platelets and HEL92.1.7 cells. Human platelets (Left Panel) and HEL92.1.7 cells (Right Panel) were stained with either Alexa Fluor® 647 Mouse IgG2b, κ Isotype Control (Cat. No. 557903; dashed line histogram) or Alexa Fluor® 647 Mouse Anti-Human CD110 antibody (Cat. No. 562188; solid line histogram). Flow cytometric fluorescence histograms were derived from gated events with the forward and side light-scatter characteristics of platelets or viable HEL92.1.7 cells. Flow cytometry was performed using a BD™ LSR II Flow Cytometer System.
Product Details
Down Arrow Up Arrow


BD Pharmingen™
C-MPL; MPL; MPLV; TPOR; Thrombopoietin receptor
Human (QC Testing)
Mouse IgG2b, κ
Flow cytometry (Routinely Tested)
0.2 mg/ml
AB_10896977
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to Alexa Fluor® 647 under optimum conditions, and unreacted Alexa Fluor® 647 was removed.

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Alexa Fluor® 647 fluorochrome emission is collected at the same instrument settings as for allophycocyanin (APC).
  4. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  5. The Alexa Fluor®, Pacific Blue™, and Cascade Blue® dye antibody conjugates in this product are sold under license from Molecular Probes, Inc. for research use only, excluding use in combination with microarrays, or as analyte specific reagents. The Alexa Fluor® dyes (except for Alexa Fluor® 430), Pacific Blue™ dye, and Cascade Blue® dye are covered by pending and issued patents.
  6. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  7. Alexa Fluor® is a registered trademark of Molecular Probes, Inc., Eugene, OR.
  8. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
562188 Rev. 3
Antibody Details
Down Arrow Up Arrow
1.6.1

The 1.6.1 monoclonal antibody specifically binds to the human Thrombopoietin Receptor (TPO-R) that is also known as the Myeloproliferative leukemia protein (c-Mpl) or CD110. CD110 is a type I transmembrane glycoprotein and a member of the hematopoietin receptor family. It is expressed on hematopoietic stem cells, a subfraction of hematopoietic precursor cells, cells of the megakaryocytic lineage and platelets. CD110 serves as a receptor for thrombopoietin. Upon binding of thrombopoietin to CD110, megakaryocyte proliferation and differentiation is induced, platelets are produced and stem cells are protected from apoptosis.

562188 Rev. 3
Format Details
Down Arrow Up Arrow
Alexa Fluor™ 647
Alexa Fluor™ 647 Dye is part of the BD red family of dyes. This is a small organic fluorochrome with an excitation maximum (Ex Max) at 653-nm and an emission maximum (Em Max) at 669-nm. Alexa Fluor 647 is designed to be excited by the Red laser (627-640 nm) and detected using an optical filter centered near 520-nm (e.g., a 660/20 nm bandpass filter). Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
Alexa Fluor™ 647
Red 627-640 nm
653 nm
669 nm
562188 Rev.3
Citations & References
Down Arrow Up Arrow

Development References (5)

  1. Abbott C, Huang G, Ellison AR, et al. Mouse monoclonal antibodies against human c-Mpl and characterization for flow cytometry applications.. Hybridoma (Larchmt). 2010; 29(2):103-13. (Clone-specific: Flow cytometry). View Reference
  2. Broudy VC, Lin NL, Fox N, Taga T, Saito M, Kaushansky K. Thrombopoietin stimulates colony-forming unit-megakaryocyte proliferation and megakaryocyte maturation independently of cytokines that signal through the gp130 receptor subunit. Blood. 1996; 88(6):2026-2032. (Biology). View Reference
  3. Deng B, Banu N, Malloy B, et al. An agonist murine monoclonal antibody to the human c-Mpl receptor stimulates megakaryocytopoiesis. Blood. 1998; 92(6):1981-1988. (Biology). View Reference
  4. Fox NE, Lim J, Chen R, Geddis AE. F104S c-Mpl responds to a transmembrane domain-binding thrombopoietin receptor agonist: proof of concept that selected receptor mutations in congenital amegakaryocytic thrombocytopenia can be stimulated with alternative thrombopoietic agents. Exp Hematol. 2010; 38(5):384-391. (Clone-specific: Flow cytometry). View Reference
  5. Gotoh A, Ritchie A, Takahira H, Broxmeyer HE. Thrombopoietin and erythropoietin activate inside-out signaling of integrin and enhance adhesion to immobilized fibronectin in human growth-factor-dependent hematopoietic cells. Ann Hematol. 1997; 75(5-6):207-213. (Biology). View Reference
View All (5) View Less
562188 Rev. 3

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.