Skip to main content Skip to navigation
PE-CF594 Mouse Anti-Human TACTILE (CD96)
Alert icon
Improve data resolution with PE-CF594 alternative with reduced spillover and enhanced brightness! Try BD RealBlue™ 613 SKU# [758312] today! More Info on RB613 #
PE-CF594 Mouse Anti-Human TACTILE (CD96)
Two-color flow cytometric analysis of TACTILE (CD96) expression on Human peripheral blood lymphocytes. The flow cytometric data from the same stained cells was reanalyzed to generate the bivariate pseudocolor density plot showing the correlated expression of TACTILE (CD96) [or Ig Isotype control staining] versus CD3 for gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ software.
PE-CF594 Mouse Anti-Human TACTILE (CD96)
Multiparameter flow cytometric analysis of TACTILE (CD96) expression on Human peripheral blood leukocyte populations.  Human whole blood was stained with BD Horizon™ BV421 Mouse Anti-Human CD3 antibody (Cat No. 562426/562427) and with either BD Horizon™ PE-CF594 Mouse IgG1, κ Isotype Control (Cat No. 562292; Left Plot) or BD Horizon™ PE-CF594 Mouse Anti-Human TACTILE (CD96) antibody (Cat No. 570070/570151; Right Plot). Erythrocytes were lysed with BD FACS Lysing™ Solution (Cat. No. 349202). The bivariate pseudocolor density plot showing the correlated expression of TACTILE (CD96) [or Ig Isotype control staining] versus side light-scatter (SSC-A) signals was derived from gated events with the forward and side light-scatter characteristics of intact leukocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ software.
Two-color flow cytometric analysis of TACTILE (CD96) expression on Human peripheral blood lymphocytes. The flow cytometric data from the same stained cells was reanalyzed to generate the bivariate pseudocolor density plot showing the correlated expression of TACTILE (CD96) [or Ig Isotype control staining] versus CD3 for gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ software.
Multiparameter flow cytometric analysis of TACTILE (CD96) expression on Human peripheral blood leukocyte populations.  Human whole blood was stained with BD Horizon™ BV421 Mouse Anti-Human CD3 antibody (Cat No. 562426/562427) and with either BD Horizon™ PE-CF594 Mouse IgG1, κ Isotype Control (Cat No. 562292; Left Plot) or BD Horizon™ PE-CF594 Mouse Anti-Human TACTILE (CD96) antibody (Cat No. 570070/570151; Right Plot). Erythrocytes were lysed with BD FACS Lysing™ Solution (Cat. No. 349202). The bivariate pseudocolor density plot showing the correlated expression of TACTILE (CD96) [or Ig Isotype control staining] versus side light-scatter (SSC-A) signals was derived from gated events with the forward and side light-scatter characteristics of intact leukocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ software.
Product Details
Down Arrow Up Arrow


BD Horizon™
hCD96; T cell-activated increased late expression protein
Human (QC Testing)
Mouse IgG1, κ
Human NK92 Cell Line
Flow cytometry (Routinely Tested)
5 µl/test
10225
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation And Storage

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unconjugated antibody and free dye were removed. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation).  When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells.  However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls.  It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. An isotype control should be used at the same concentration as the antibody of interest.
  7. Please observe the following precautions: We recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to protect exposure of conjugated reagents, including cells stained with those reagents, to any room illumination. Absorption of visible light can significantly affect the emission spectra and quantum yield of tandem fluorochrome conjugates.
  8. When excited by the yellow-green (561-nm) laser, the fluorescence may be brighter than when excited by the blue (488-nm) laser.
  9. This product is provided under an Agreement between BIOTIUM and BD Biosciences. The manufacture, use, sale, offer for sale, or import of this product is subject to one or more patents or pending applications owned or licensed by Biotium, Inc. This product, and only in the amount purchased by buyer, may be used solely for buyer’s own internal research, in a manner consistent with the accompanying product literature. No other right to use, sell or otherwise transfer (a) this product, or (b) its components is hereby granted expressly, by implication or by estoppel. This product is for research use only. Diagnostic uses require a separate license from Biotium, Inc. For information on purchasing a license to this product including for purposes other than research, contact Biotium, Inc., 3159 Corporate Place, Hayward, CA 94545, Tel: (510) 265-1027. Fax: (510) 265-1352. Email: btinfo@biotium.com.
  10. Because of the broad absorption spectrum of the tandem fluorochrome, extra care must be taken when using multi-laser cytometers, which may directly excite both PE and CF™594.
  11. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  12. CF™ is a trademark of Biotium, Inc.
  13. Texas Red is a registered trademark of Molecular Probes, Inc., Eugene, OR.
  14. For U.S. patents that may apply, see bd.com/patents.
570151 Rev. 1
Antibody Details
Down Arrow Up Arrow
NK92.39.rMAb

The NK92.39.rMAb monoclonal antibody specifically recognizes human CD96 which is also known as TACTILE (T cell activation increased late expression). CD96 is a type I membrane glycoprotein comprised of three N-terminal Ig-like extracellular domains followed by one mucin-like domain, a transmembrane region, and a cytoplasmic tail with one basic/proline rich motif, a single ITIM motif, and an YXXM motif which is also present in ICOS and CD28. CD96 is expressed at low levels on resting natural killer (NK) cells and T cells and at high levels on activated NK and T cells. CD96 is also expressed at low levels on some B cells and on some T-cell leukemia and acute myeloid leukemia cells. CD96 plays a role in the adhesive interactions of activated NK and T cells with target cells during immune responses. CD96 binds to the poliovirus receptor (CD155) that is highly expressed on some tumor cells. CD155-mediated ligation of CD96 can activate NK cell-mediated cytotoxicity.

570151 Rev. 1
Format Details
Down Arrow Up Arrow
PE-CF594
BD Horizon™ PE-CF594 dye is a part of the BD PE family of dyes. This tandem fluorochrome is comprised of a R-Phycoerythrin (PE) donor that has excitation maxima (Ex Max) of 496-nm and 566-nm and an acceptor dye with an emission maximum (Em Max) at 615-nm. PE-CF594, driven by BD innovation, is designed to be excited by the blue (488-nm), Green (532-nm) and yellow-green (561-nm) lasers and detected using an optical filter centered near 615 nm (e.g., a 610/20-nm bandpass filter). The donor dye can be excited by the Blue (488-nm), Green (532-nm) and yellow-green (561-nm) lasers and the acceptor dye can be excited by the green (532-nm) laser resulting in cross-laser excitation and fluorescence spillover. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE-CF594
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
615 nm
570151 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "570151" on CiteAb

Development References (3)

  1. El-Sherbiny YM, Meade JL, Holmes TD, et al. The requirement for DNAM-1, NKG2D, and NKp46 in the natural killer cell-mediated killing of myeloma cells.. Cancer Res. 2007; 67(18):8444-9. (Clone-specific). View Reference
  2. Fuchs A, Cella M, Giurisato E, Shaw AS, Colonna M. Cutting edge: CD96 (tactile) promotes NK cell-target cell adhesion by interacting with the poliovirus receptor (CD155).. J Immunol. 2004; 172(7):3994-8. (Immunogen). View Reference
  3. Toutirais O, Cabillic F, Le Friec G, et al. DNAX accessory molecule-1 (CD226) promotes human hepatocellular carcinoma cell lysis by Vgamma9Vdelta2 T cells.. Eur J Immunol. 2009; 39(5):1361-8. (Clone-specific). View Reference
570151 Rev. 1

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.