Skip to main content Skip to navigation
BB700 Mouse Anti-Mouse CD66a (CEACAM1a)

BD OptiBuild™ BB700 Mouse Anti-Mouse CD66a (CEACAM1a)

Clone CC1 (also known as MAb-CCl; mAb CC1)

(RUO)
Product Details
Down Arrow Up Arrow


BD OptiBuild™
CEACAM1[a]; Ceacam1; BGP-1; Bgp; MHV-R; MHVR
Mouse (Tested in Development)
Mouse SJL IgG1, κ
BALB/c mouse intestinal brush border membrane proteins
Flow cytometry (Qualified)
0.2 mg/ml
AB_2874973
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

BD™ CompBeads can be used as surrogates to assess fluorescence spillover (Compensation). When fluorochrome conjugated antibodies are bound to BD CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD CompBead to ensure that BD CompBeads are appropriate for your specific cellular application.

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes are used in the same experiment. Fluorescent dye interactions may cause staining artifacts which may affect data interpretation. The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).

Product Notices

  1. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  2. Researchers should determine the optimal concentration of this reagent for their individual applications.
  3. An isotype control should be used at the same concentration as the antibody of interest.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  7. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  8. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  9. BD Horizon Brilliant Blue 700 is covered by one or more of the following US patents: 8,455,613 and 8,575,303.
  10. Cy is a trademark of GE Healthcare.
750877 Rev. 2
Antibody Details
Down Arrow Up Arrow
CC1

The CC1 monoclonal antibody specifically recognizes carcinoembryonic antigen-related cell adhesion molecule 1a (CEACAM1a or CEACAM1[a]), an allotypic form of CEACAM1 which is also known as CD66a, Murine hepatitis virus receptor (MHV-R), or Biliary glycoprotein 1 (BGP-1). Four known isoforms of mouse CD66a arise from alternative splicing of RNA transcripts encoded by Ceacam1, a member of the carcinoembryonic antigen (CEA) family and Ig gene superfamily. These isoforms are type I transmembrane proteins that include a heavily glycosylated extracellular region with an N-terminal IgV-like domain and up to three IgC2-like domains followed by a transmembrane region and a cytoplasmic tail of relatively short (10 amino acids) or long (73 amino acids) length. The cytoplasmic tails enable interactions with other intracellular molecules to initiate or regulate cellular responses. The two CD66a isoforms with long cytoplasmic tails contain immunoreceptor tyrosine-based inhibitory motifs (ITIMs) that may enable CD66a to function as an immune checkpoint inhibitor. CD66a is expressed on a variety of cell types including certain epithelial cells, endothelial cells, B cells, activated T cells, NK cells, monocytes, dendritic cells (DC), and neutrophils. CD66a (CEACAM1a) is a multifunctional protein. Through their IgV-like domain, CD66a (CEACAM1a) molecules function as homophilic and heterophilic intercellular adhesion molecules. They can also function as MHV-Rs, angiogenic factors, regulators of cellular proliferation and differentiation, and tumor suppressors. Two distinct Ceacam1 alleles, (a and b), exist because of differences in their IgV-like domain gene sequences. Ceacam1a is found in most inbred mouse strains including BALB/c, C57BL/6, and C3H mice whereas Ceacam1b is found in SJL mice. CD66a (CEACAM1a) proteins are specifically bound by the CC1 antibody whereas CEACAM1b proteins are not. The CC1 antibody recognizes an epitope in the N-terminal domain of mouse CD66a (CEACAM1a) proteins.

The antibody was conjugated to BD Horizon BB700, which is part of the BD Horizon Brilliant™ Blue family of dyes.   It is a polymer-based tandem dye developed exclusively by BD Biosciences.  With an excitation max of 485 nm and an emission max of 693 nm, BD Horizon BB700 can be excited by the 488 nm laser and detected in a standard PerCP-Cy™5.5 set (eg, 695/40-nm filter). This dye provides a much brighter alternative to PerCP-Cy5.5 with less cross laser excitation off the 405 nm and 355 nm lasers.

750877 Rev. 2
Format Details
Down Arrow Up Arrow
BB700
The BD Horizon Brilliant™ Blue 700 (BB700) Dye is part of the BD Horizon Brilliant™ Blue family of dyes. This tandem fluorochrome is comprised of a polymer-technology dye donor with an excitation maximum (Ex Max) of 476-nm and an acceptor dye with an emission maximum (Em Max) at 695-nm. Driven by BD innovation, BB700 is designed to be excited by the blue laser (488-nm) and detected using an optical filter centered near 695-nm (e.g., a 695/20-nm bandpass filter). The donor dye can be excited by the Violet (405 nm) laser and the acceptor dye can be excited by the red (627–640 nm) laser resulting in cross-laser excitation and fluorescence spillover. BB700 Reagents are significantly brighter than equivalent PerCP or PerCP-Cy5.5 reagents and are less sensitive to photobleaching. In addition, BB700 shows much less excitation by the violet (407-nm) laser resulting in less spillover. BB700 has minimal yellow green (562-nm) excitation and is ideal for instruments with both blue (488-nm) and yellow green (562-nm) lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BB700
Blue 488 nm
476 nm
695 nm
750877 Rev.2
Citations & References
Down Arrow Up Arrow

Development References (3)

  1. Dveksler GS, Dieffenbach CW, Cardellichio CB, et al. J Virol. 1993; 67(1):1-8. (Clone-specific). View Reference
  2. Dveksler GS, Pensiero MN, Cardellichio CB, et al. Cloning of the mouse hepatitis virus (MHV) receptor: expression in human and hamster cell lines confers susceptibility to MHV. J Virol. 1991; 65(12):6881-6891. (Clone-specific). View Reference
  3. Williams RK, Jiang GS, Snyder SW, Frana MF, Holmes KV.. Purification of the 110-kilodalton glycoprotein receptor for mouse hepatitis virus (MHV)-A59 from mouse liver and identification of a nonfunctional, homologous protein in MHV-resistant SJL/J mice. J Virol. 1990; 64(8):3817-3823. (Immunogen). View Reference
750877 Rev. 2

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.