Skip to main content Skip to navigation
BV750 Mouse Anti-Human TCR Vβ5.2/5.3
Alert icon
If you're planning to order more than 10 BD OptiBuild™ Reagents, please contact your local sales representative to place this order. Contact Us #
Product Details
Down Arrow Up Arrow


BD OptiBuild™
TCR Vβ5.2, TRBV5-6, TCRBV5S2; TCR Vβ5.3, TRBV5-5, TCRBV5S3
Human (Tested in Development)
Mouse IgG2a, κ
Flow cytometry (Qualified)
0.2 mg/ml
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

BD™ CompBeads can be used as surrogates to assess fluorescence spillover (Compensation).  When fluorochrome conjugated antibodies are bound to CompBeads, they have spectral properties very similar to cells.   However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls.  It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and CompBead to ensure that BD Comp beads are appropriate for your specific cellular application.

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes are used in the same experiment.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions.  More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).

Product Notices

  1. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  2. Researchers should determine the optimal concentration of this reagent for their individual applications.
  3. An isotype control should be used at the same concentration as the antibody of interest.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  7. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  8. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  9. BD Horizon Brilliant™ Violet 750 is covered by one or more of the following US patents: 8,158,444; 8,802,450; 8,575,303; 8,455,613; 8,227,187; 8,841,072; 8,110,673.
752679 Rev. 1
Antibody Details
Down Arrow Up Arrow
MH3-2

The MH3-2 monoclonal antibody specifically recognizes the human variable beta 5.2 (TCR Vβ5.2) and variable beta 5.3 (TCR Vβ5.3) domains of the beta subunit for the αβ T cell receptor (TCR Vβ5.2/5.3). The TCR Vβ5.2 and TCR Vβ5.3 domains are encoded by the TRBV5-6 (T cell receptor beta variable 5-6; also known as TCRBV5S2) and TRBV5-5 (T cell receptor beta variable 5-5; TCRBV5S3) gene segments of the multimembered Vβ5 subfamily within the TRB (T cell receptor beta locus), respectively. Functional T-cell receptor beta chains (TCR-β) are generated by genomic rearrangement of TCR variable (Vβ), diversity (Dβ), joining (Jβ) and constant (Cβ) region gene segments by precursor T cells. Distinct αβ TCR containing either TCR Vβ5.2 or TCR Vβ5.3 are clonally expressed on subsets of thymocytes or peripheral CD4+ or CD8+ T cells. These TCR β beta chains can heterodimerize with TCR α chains to form αβ TCR that function as signaling T cell receptors for antigen. Human αβ TCR recognize peptides presented by HLA (MHC) molecules and in conjunction with the associated CD3 complex, can transduce intracellular signals that initiate precursor or mature T cell responses. The MH3-2 antibody may be useful for analyzing the frequencies or numbers of TCR Vβ5.2/5.3-positive thymocytes or mature T cells as well as the levels of TCR Vβ5.2/5.3 expressed by these cells. The MH3-2 antibody can be used in research applications such as flow cytometry to help characterize the TCR Vβ repertoires of precursor or mature T cell populations.

The antibody was conjugated to BD Horizon BV750 which is part of the BD Horizon Brilliant™ Violet family of dyes. This dye is a tandem fluorochrome of BD Horizon BV421 with an Ex Max of 405-nm and an acceptor dye with an Em Max at 750-nm. BD Horizon Brilliant BV750 can be excited by the violet laser (405 nm) and detected with a 750/30 nm filter with a 740 nm long pass. Due to spectral differences between labeled cells and beads, using BD™ CompBeads can result in incorrect spillover values when used with BD Horizon BV750 reagents. Therefore, the use of BD CompBeads or BD CompBeads Plus to determine spillover values for these reagents is not recommended.

752679 Rev. 1
Format Details
Down Arrow Up Arrow
BV750
The BD Horizon Brilliant Violet™ 750 (BV750) dye is part of the BD Horizon Brilliant Violet™ family of dyes. This tandem fluorochrome is comprised of a BV421 donor with an excitation maximum (Ex Max) of 409-nm and an acceptor dye with an emission maximum (Em Max) at 754-nm. BV750, driven by BD innovation, is designed to be excited by the violet laser (405-nm) and detected using an optical filter centered near 750-nm (e.g., a 750/30 nm bandpass filter). Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BV750
Violet 405 nm
409 nm
754 nm
752679 Rev.1
Citations & References
Down Arrow Up Arrow

Development References (7)

  1. Folch G, Jabado-Michaloud J, Lefranc M-P. Reagents monoclonal antibodies: anti-human TRBV, IMGT repertoire, IMGT Web resources. http://www.imgt.org/IMGTrepertoire/Regulation/antibodies/human/TRB/TRBV/Hu_TRBVMab.html. IMGT®. 2020; 4. (Clone-specific: Flow cytometry).
  2. Kabelitz D, Wesch, D. T-Cell Receptor Analysis by Flow Cytometry. In: Sack U, Tarnok A, Rothe G. Sack U, Tarnok A, Rothe G, ed. Basic Principles, Methods and Clinical Applications of Flow Cytometry. New York: Karger, Basel; 2009:200-210. View Reference
  3. Labrecque N, McGrath H, Subramanyam M, Huber BT, Sékaly RP. Human T cells respond to mouse mammary tumor virus-encoded superantigen: V beta restriction and conserved evolutionary features.. J Exp Med. 1993; 177(6):1735-43. (Clone-specific: Flow cytometry). View Reference
  4. Oh S, Terabe M, Pendleton CD, et al. Human CTLs to wild-type and enhanced epitopes of a novel prostate and breast tumor-associated protein, TARP, lyse human breast cancer cells.. Cancer Res. 2004; 64(7):2610-8. (Clone-specific: Flow cytometry). View Reference
  5. Posnett DN, Romagne F, Necker A, Kotzin BL, Sékaly R-P. First human TCR monoclonal antibody workshop. The Immunologist. 1996; 4(1):5-8. (Clone-specific).
  6. Soudeyns H, Champagne P, Holloway CL, et al. Transient T cell receptor beta-chain variable region-specific expansions of CD4+ and CD8+ T cells during the early phase of pediatric human immunodeficiency virus infection: characterization of expanded cell populations by T cell receptor phenotyping.. J Infect Dis. 2000; 181(1):107-20. (Clone-specific: Flow cytometry). View Reference
  7. Vonderheid EC, Boselli CM, Conroy M, et al. Evidence for restricted Vbeta usage in the leukemic phase of cutaneous T cell lymphoma.. J Invest Dermatol. 2005; 124(3):651-61. (Clone-specific: Flow cytometry). View Reference
View All (7) View Less
752679 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.