-
Your selected country is
Finland
- Change country/language
Old Browser
This page has been recently translated and is available in French now.
Looks like you're visiting us from {countryName}.
Would you like to stay on the current country site or be switched to your country?
Multicolor flow cytometric analysis of IL-22 expression in human peripheral blood mononuclear cells (PBMCs). PBMCs were cultured in complete tissue culture medium with Phorbol 12-Myristate 13-Acetate (PMA; Sigma, 50 ng/ml) and Ionomycin (Sigma, 500 ng/ml) in the presence of BD GolgiPlug™ Protein Transport Inhibitor (Cat. No. 555029) for 6 hours. The cells were harvested, then fixed and permeabilized using BD Cytofix™ Fixation Buffer (Cat. No. 554655) and BD Perm/Wash™ buffer (Cat. No. 554723). The cells were then stained with BD Horizon™ BV421 Mouse Anti-Human CD4 (Cat. No. 562424/562425) and either BD Horizon™ BB700 Mouse IgG2a, κ Isotype Control (Cat. No. 566419; Left Plot) or BD Horizon™ BB700 Mouse anti-Human IL-22 antibody (Cat. No. 567688/567689; Right Plot) at 0.125 µg/test. Bivariate pseudocolor density plots showing the correlated expression of IL-22 (or Ig Isotype control staining) versus CD4 were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometry and data analysis were performed using a BD X-20 LSRFortessa™ Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
BD Horizon™ BB700 Mouse Anti-Human IL-22
Regulatory Status Legend
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Preparation And Storage
Recommended Assay Procedures
BD® CompBeads can be used as surrogates to assess fluorescence spillover (Compensation). When fluorochrome conjugated antibodies are bound to CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and CompBead to ensure that BD® CompBeads are appropriate for your specific cellular application.
For optimal and reproducible results, BD Horizon Brilliant™ Stain Buffer should be used anytime BD Horizon Brilliant™ dyes are used in a multicolor flow cytometry panel. Fluorescent dye interactions may cause staining artifacts which may affect data interpretation. The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. When BD Horizon Brilliant Stain Buffer is used in in the multicolor panel, it should also be used in the corresponding compensation controls for all dyes to achieve the most accurate compensation. For the most accurate compensation, compensation controls created with either cells or beads should be exposed to BD Horizon Brilliant Stain Buffer for the same length of time as the corresponding multicolor panel. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).
For optimal results, it is recommended to perform two washes after staining with antibodies. Cells may be prepared, stained with antibodies and washed twice with wash buffer per established protocols for immunofluorescent staining prior to acquisition on a flow cytometer. Performing fewer than the recommended wash steps may lead to increased spread of the negative population.
Product Notices
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- An isotype control should be used at the same concentration as the antibody of interest.
- BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
- BD Horizon Brilliant Blue 700 is covered by one or more of the following US patents: 8,455,613 and 8,575,303.
- Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
- Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.
- Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
Companion Products
The MH22B2 monoclonal antibody specifically recognizes human Interleukin-22 (IL-22), which is encoded by the IL22 gene. Cross-reactivity of MH22B2 mAb to mouse IL-22 (which shares 79% amino acid identity with human IL-22) has been observed by ELISA and by flow cytometry of HEK293 cells transfected with mouse IL-22 and TH17-differentiated CD4-positive T cells from C57BL/6 mice. IL-22 (with or without other cytokines) is secreted by many T-cell and innate-lymphoid-cell populations. Evidence that IL-22 plays a key role in mucosal immunity includes the restricted expression of the alpha subunit of the heterodimeric IL-22 receptor, called IL-22R1, on epithelial cells and cells of epithelial origin. At epithelial surfaces, IL-22 elicits antimicrobial defenses and maintains epithelial integrity. Alternatively, uncontrolled IL-22 production can result in certain inflammatory disorders. Regulation of IL-22 expression is complex, involving other cytokines (eg, IL-6, IL-23, and TGF-β) and many transcription factors, (eg, AHR, c-Maf, STAT3, RORɤT, BATF, and others).
Development References (8)
-
Colonna M. Interleukin-22-producing natural killer cells and lymphoid tissue inducer-like cells in mucosal immunity.. Immunity. 2009; 31(1):15-23. (Biology). View Reference
-
Le-Thi-Phuong T, Dumoutier L, Renauld JC, Van Snick J, Coutelier JP. Divergent roles of IFNs in the sensitization to endotoxin shock by lactate dehydrogenase-elevating virus.. Int Immunol. 2007; 19(11):1303-11. (Clone-specific: ELISA). View Reference
-
Martin B, Hirota K, Cua DJ, Stockinger B, Veldhoen M. Interleukin-17-producing gammadelta T cells selectively expand in response to pathogen products and environmental signals.. Immunity. 2009; 31(2):321-30. (Clone-specific: Flow cytometry). View Reference
-
Rutz S, Eidenschenk C, Ouyang W. IL-22, not simply a Th17 cytokine.. Immunol Rev. 2013; 252(1):116-32. (Biology). View Reference
-
Suurmond J, Habets KL, Dorjée AL, Huizinga TW, Toes RE. Expansion of Th17 Cells by Human Mast Cells Is Driven by Inflammasome-Independent IL-1β. J Immunol. 2016; 164(11):4473-4481. (Biology). View Reference
-
Trifari S, Kaplan CD, Tran EH, Crellin NK, Spits H. Identification of a human helper T cell population that has abundant production of interleukin 22 and is distinct from T(H)-17, T(H)1 and T(H)2 cells.. Nat Immunol. 2009; 10(8):864-71. (Biology). View Reference
-
Veldhoen M, Hirota K, Westendorf AM, et al. The aryl hydrocarbon receptor links TH17-cell-mediated autoimmunity to environmental toxins.. Nature. 2008; 453(7191):106-9. (Immunogen: Flow cytometry). View Reference
-
Zenewicz LA. IL-22: There Is a Gap in Our Knowledge.. Immunohorizons. 2018; 2(6):198-207. (Biology). View Reference
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.