Mouse IL-17F Flex Set

BD™ Cytometric Bead Array (CBA) Mouse IL-17F Flex Set

(RUO)
Mouse IL-17F Flex Set
Figure 1. Example BD CBA Mouse IL-17F Flex Set standard curve. Data acquired using a BD FACSArray bioanalyzer and analyzed using FCAP Array Software.
Mouse IL-17F Flex Set
Linearity: Cell culture supernatant and 1:4 diluted pooled mouse serum were spiked with protein and serially diluted. The diluted samples were assayed and the results were compared with the original spiked sample.
Mouse IL-17F Flex Set
Recovery:        Cell culture supernatant and pooled mouse serum were spiked with three different levels of protein. The spiked samples were assayed and the results were compared with expected values. Serum samples were diluted 1:4 before the protein was spiked into each. Serum used was commercially available pooled mouse serum.
Mouse IL-17F Flex Set
Reproducibility: The intra-assay and inter-assay reproducibility were determined for the BD CBA Mouse IL-17F Flex Set by evaluating ten replicates of three different sample levels (intra-assay) and three replicates of three different sample levels from four separate experiments (inter-assay).
Figure 1. Example BD CBA Mouse IL-17F Flex Set standard curve. Data acquired using a BD FACSArray bioanalyzer and analyzed using FCAP Array Software.
Linearity: Cell culture supernatant and 1:4 diluted pooled mouse serum were spiked with protein and serially diluted. The diluted samples were assayed and the results were compared with the original spiked sample.
Recovery:        Cell culture supernatant and pooled mouse serum were spiked with three different levels of protein. The spiked samples were assayed and the results were compared with expected values. Serum samples were diluted 1:4 before the protein was spiked into each. Serum used was commercially available pooled mouse serum.
Reproducibility: The intra-assay and inter-assay reproducibility were determined for the BD CBA Mouse IL-17F Flex Set by evaluating ten replicates of three different sample levels (intra-assay) and three replicates of three different sample levels from four separate experiments (inter-assay).
Product Details
Down Arrow Up Arrow


BD™ Cytometric Bead Array (CBA)
D6
10-2,500 pg/mL
Mouse (QC Testing)
RUO
AB_2869399


Description

The BD™ CBA Mouse IL-17F Flex Set is a bead-based immunoassay capable of measuring mouse Interleukin-17F (IL-17F) in serum and cell culture supernatant samples. Mouse reactivity was determined by testing samples with the BD CBA Mouse IL-17F Flex Set. The biology and function of IL-17F has been extensively reviewed in the literature. For more information on bead-based immunoassays, refer to the product insert for the BD CBA Mouse/Rat Soluble Protein Master Buffer Kit (Cat. No. 558266 or 558267).

Preparation And Storage

This BD™ CBA Flex Set contains one vial each of Capture Bead and PE Detection Reagent and two vials of Standard. The Capture Bead and PE Detection Reagent components of this flex set have been formulated to a 50x concentration to ensure product performance when multiplexed. The Standard component is lyophilized and should be transferred to a 15 mL polypropylene tube for reconstitution. When reconstituted in 4.0 mL Assay Diluent, the standard has a protein concentration of 2,500 pg/mL. Discard unused reconstituted standard, do not store or reuse. Store lyophilized standard and other components at 4°C. Protect Capture Beads and the PE Detection Reagent from prolonged exposure to light.

Recommended Assay Procedures

The BD CBA Mouse IL-17F Flex Set must be used in conjunction with a BD CBA Mouse/Rat Soluble Protein Master Buffer Kit (Cat. No. 558266, 100 tests, or 558267, 500 tests), a flow cytometer, and FCAP Array™ Software.  Detailed instructions on the use of this product can be found in the manual for the BD CBA Mouse/Rat Soluble Protein Master Buffer Kit. When following the directions in the Master Buffer Kit, the top standard point for the BD CBA Mouse IL-17F Flex Set will be 2500 pg/mL. An example standard curve is shown in Figure 1.

The BD CBA Mouse IL-17F Flex Set should not be used in the same assay well with any non-BD CBA Mouse Soluble Protein Flex Set Reagents, which include: Human Soluble Protein, Human Enhanced Sensitivity, Human Soluble Receptor and Cell Signalling Flex Sets.  For an updated assay compatibility chart for the BD CBA Mouse Soluble Protein Flex Sets, please visit http://www.bdbiosciences.com/cbasetup.

Performance

Limit of Detection: The theoretical limit of detection is 0.81 pg/mL and was determined by evaluating the estimated result of the average MFI of the negative control (0 pg/mL, n=30) + 2 standard deviations.

Product Notices

  1. ProClin is a trademark of Rohm and Haas Company.
  2. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. Warning: CBA lyophilized standard contains 0.02% (w/w) of a CMIT/MIT mixture (3:1), which is a mixture of:5-chloro-2-methyl-4-isothiazolin-3-one [EC No 247-500-7] and 2-methyl-4-isothiazolin-3-one [EC No 220-239-6] (3:1).Hazard statement: May cause an allergic skin reaction.Precautionary statements: Contaminated work clothing should not be allowed out of the workplace. Wear protective gloves/eye/face protection. Wear protective clothing. Avoid breathing mist/vapours/spray. If skin irritation or rash occurs: Get medical advice/attention. IF ON SKIN: Wash with plenty of water. Take off contaminated clothing and wash it before reuse. Dispose of contents/container in accordance with local/regional/national/international regulations.
562174 Rev. 3
Components
Down Arrow Up Arrow
Description Quantity/Size Part Number EntrezGene ID
Mouse IL-17F Standard N/A 51-9007439 N/A
Mouse IL-17F PE Detection Reagent N/A 51-9007554 N/A
Mouse IL-17F Capture Bead D6 100 Tests (1 ea) 51-9007558 N/A
562174 Rev. 3

Please refer to Support Documents for Quality Certificates

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.