Skip to main content Skip to navigation
R718 Mouse Anti-Human CD1d
R718 Mouse Anti-Human CD1d
Multiparameter flow cytometric analysis of CD1d expression on different human peripheral blood leucocyte populations. Whole blood was stained with FITC Mouse Anti-Human CD19 antibody (Cat. No. 555412/560994; Bottom Plots) and with either BD Horizon™ R718 Mouse IgG1, κ Isotype Control (Cat. No. 566928; Left Plots) or BD Horizon™ R718 Mouse Anti-Human CD1d antibody (Cat. No. 567984/567985; Right Plots). Erythrocytes were lysed with BD FACS Lysing Solution (Cat. No. 349202). Bivariate pseudocolor density plots showing the correlated expression of CD1d (or Ig Isotype control staining) versus side-light scatter (SSC-A) signals (Top Plots) or CD19 (Bottom Plots) were derived from gated events with the forward and side-light scatter characteristics of intact leucocyte populations. Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software.
Multiparameter flow cytometric analysis of CD1d expression on different human peripheral blood leucocyte populations. Whole blood was stained with FITC Mouse Anti-Human CD19 antibody (Cat. No. 555412/560994; Bottom Plots) and with either BD Horizon™ R718 Mouse IgG1, κ Isotype Control (Cat. No. 566928; Left Plots) or BD Horizon™ R718 Mouse Anti-Human CD1d antibody (Cat. No. 567984/567985; Right Plots). Erythrocytes were lysed with BD FACS Lysing Solution (Cat. No. 349202). Bivariate pseudocolor density plots showing the correlated expression of CD1d (or Ig Isotype control staining) versus side-light scatter (SSC-A) signals (Top Plots) or CD19 (Bottom Plots) were derived from gated events with the forward and side-light scatter characteristics of intact leucocyte populations. Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software.
Product Details
Down Arrow Up Arrow


BD Horizon™
R3; R3G1; HMC class I antigen-like glycoprotein CD1D
Human (QC Testing)
Mouse BALB/c IgG1, κ
Human CD1d Recombinant Protein
Flow cytometry (Routinely Tested)
5 µl
912
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unreacted dye was removed.

Recommended Assay Procedures

BD™ CompBeads can be used as surrogates to assess fluorescence spillover (Compensation). When fluorochrome conjugated antibodies are bound to BD CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD CompBead to ensure that BD CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  3. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  4. An isotype control should be used at the same concentration as the antibody of interest.
  5. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  6. This product is provided under an Agreement between BIOTIUM and BD Biosciences. This product, and only in the amount purchased by buyer, may be used solely for buyer’s own internal research, in a manner consistent with the accompanying product literature. No other right to use, sell or otherwise transfer (a) this product, or (b) its components is hereby granted expressly, by implication or by estoppel. This product is for research use only. Diagnostic uses require a separate license from Biotium, Inc. For information on purchasing a license to this product including for purposes other than research, contact Biotium, Inc., 3159 Corporate Place, Hayward, CA 94545, Tel: (510) 265-1027. Fax: (510) 265-1352. Email: btinfo@biotium.com.
  7. Alexa Fluor™ is a trademark of Life Technologies Corporation.
567984 Rev. 1
Antibody Details
Down Arrow Up Arrow
CD1d42

The CD1d42 monoclonal antibody recognizes CD1d. Cell surface CD1d is structurally homologous to Class I MHC molecules. It consists of a glycosylated type I transmembrane α chain (43-49 kDa) that is non-covalently associated with β2-microglobulin. CD1d is a member of the CD1 family of molecules, which belong to the immunoglobulin superfamily. Sequence homology data classifies the CD1 molecules into two groups. Group 1 includes CD1a, CD1b and CD1c molecules; group 2 includes CD1d molecules and their homologs in other species. CD1d is expressed on cortical thymocytes, B cells, dendritic cells, monocytes, and some nonlymphoid cells including intestinal epithelial cells, hepatocytes and keratinocytes. It is not expressed on resting mature T cells. Studies suggest that CD1d participates in lipid antigen presentation to CD1d-restricted NKT cells.

The antibody was conjugated to BD Horizon Red 718, which has been developed exclusively for BD Biosciences as a better alternative to Alexa Fluor® 700. BD Horizon Red 718 can be excited by the red laser (628 – 640 nm) and, with an Em Max around 718 nm, it can be detected using a 730/45 nm filter. Due to similar excitation and emission properties, we do not recommend using R718 in combination with APC-R700 or Alexa Fluor® 700.

567984 Rev. 1
Format Details
Down Arrow Up Arrow
R718
The BD Horizon™ Red 718 (R718) Dye is part of the BD red family of dyes. It is a small organic fluorochrome with an excitation maximum (Ex Max) at 695-nm and an emission maximum (Em Max) at 718-nm. Driven by BD innovation, R718 is designed to be excited by the red laser (627–640-nm) and detected using an optical filter centered near 720-nm (e.g., a 720/40-nm bandpass filter). R718 is a brighter alternative to Alexa Fluor™ 700. R718 is also a bright small molecule alternative to APC-R700 with lower spread into the APC detector. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
R718
Red 627-640 nm
695 nm
718 nm
567984 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "567984" on CiteAb

Development References (6)

  1. Exley M, Garcia J, Wilson SB, et al. CD1d structure and regulation on human thymocytes, peripheral blood T cells, B cells and monocytes. Immunology. 2000; 100(1):37-47. (Immunogen: Flow cytometry, Immunohistochemistry, Immunoprecipitation). View Reference
  2. Hong S, Scherer DC, Singh N. Lipid antigen presentation in the immune system: lessons learned from CD1d knockout mice. Immunol Rev. 1999; 169:31-44. (Biology). View Reference
  3. Kishimoto T. Tadamitsu Kishimoto .. et al., ed. Leucocyte typing VI : white cell differentiation antigens : proceedings of the sixth international workshop and conference held in Kobe, Japan, 10-14 November 1996. New York: Garland Pub.; 1997.
  4. Ronger-Savle S, Valladeau J, Claudy A, et al. TGFbeta inhibits CD1d expression on dendritic cells. J Invest Dermatol. 2005; 124(1):116-118. (Clone-specific: Flow cytometry). View Reference
  5. Somnay-Wadgaonkar K, Nusrat A, Kim HS. Immunolocalization of CD1d in human intestinal epithelial cells and identification of a beta2-microglobulin-associated form. 1999; 11(3):383-392. (Biology). View Reference
  6. Zola H, Swart B, Nicholson I, Voss E. CD1a–e. In: Zola H. Leukocyte and Stromal Cell Molecules : the CD Markers. Hoboken, N.J.: Wiley-Liss; 2007:42-43.
View All (6) View Less
567984 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.