Skip to main content Skip to navigation
PerCP-Cy™5.5 Mouse IgG2b, κ Isotype Control
Alert icon
Consider BD Horizon RealBlue™ 705 (RB705) Reagents, a bright and clean fluorochrome alternative to BD Horizon™ BB700 and PerCP-Cy5.5 More Info #
Product Details
Down Arrow Up Arrow


BD Pharmingen™
Isotype Control (anti-Dansyl); Anti-Dansyl; Anti-DNS
Mouse C.SW IgG2b, κ
Flow cytometry, Isotype control (Routinely Tested)
0.2 mg/ml
AB_2869668
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with PerCP-Cy5.5 under optimum conditions, and unconjugated antibody and free PerCP-Cy5.5 were removed. Storage of PerCP-Cy5.5 conjugates in unoptimized diluent is not recommended and may result in loss of signal intensity.

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. Please observe the following precautions: Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
  5. PerCP-Cy5.5–labelled antibodies can be used with FITC- and R-PE–labelled reagents in single-laser flow cytometers with no significant spectral overlap of PerCP-Cy5.5, FITC, and R-PE fluorescence.
  6. PerCP-Cy5.5 is optimized for use with a single argon ion laser emitting 488-nm light. Because of the broad absorption spectrum of the tandem fluorochrome, extra care must be taken when using dual-laser cytometers, which may directly excite both PerCP and Cy5.5™. We recommend the use of cross-beam compensation during data acquisition or software compensation during data analysis.
  7. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  8. Cy is a trademark of GE Healthcare.
  9. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
565380 Rev. 2
Antibody Details
Down Arrow Up Arrow
27-35

This mouse IgG2b, κ isotype control is a monoclonal antibody, clone 27-35, that is specific for the dansyl (5-[dimethylamino] naphthalene-1-sulfonyl) hapten. The dansyl (DNS) hapten is not expressed on human cells or human cell lines. The 27-35 immunoglobulin was selected as an isotype control following testing that demonstrated low background staining on a variety of mouse and human tissues.

565380 Rev. 2
Format Details
Down Arrow Up Arrow
PerCP-Cy5.5
PerCP-Cy5.5 dye is part of the BD blue family of dyes. This tandem fluorochrome is comprised of a fluorescent protein complex (PerCP) with an excitation maximum (Ex Max) of 482 nm and an acceptor dye with an emission maximum (Em Max) at 676 nm. PerCP-Cy5 is designed to be excited by the blue laser (488-nm) and detected using an optical filter centered near 680 nm (e.g., a 695/40 nm bandpass filter). The donor dye can be partially excited by the Violet (405-nm) laser resulting in cross-laser excitation and fluorescence spillover. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PerCP-Cy5.5
Blue 488 nm
482 nm
676 nm
565380 Rev.2
Citations & References
Down Arrow Up Arrow

Development References (4)

  1. BD Biosciences. Techniques for Immune Function Analysis, Application Handbook 1st Edition. 2003. Available: http://www.bdbiosciences.com/pdfs/manuals/02-8100055-21A1rr.pdf 2007, Jan. 25.
  2. Guesdon JL, Ternynck T, Avrameas S. The use of avidin-biotin interaction in immunoenzymatic techniques. J Histochem Cytochem. 1979; 27(8):1131-1139. (Methodology). View Reference
  3. Paliard P, Vitrey D, Fournier G, Belhadjali J, Patricot L, Berger F. Perhexiline maleate-induced hepatitis.. Digestion. 1978; 17(5):419-27. (Methodology). View Reference
  4. Prussin C, Metcalfe DD. Detection of intracytoplasmic cytokine using flow cytometry and directly conjugated anti-cytokine antibodies. J Immunol Methods. 1995; 188(1):117-128. (Methodology). View Reference
View All (4) View Less
565380 Rev. 2

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.