Skip to main content Skip to navigation
RB744 Rat Anti-Mouse CD200 Receptor 3
Product Details
Down Arrow Up Arrow


BD OptiBuild™
CD200 receptor-like 3; CD200RLb; Cd200r3; mCD200RLb
Mouse (Tested in Development)
Rat SD, also known as Sprague-Dawley (outbred) IgG2a, κ
Mouse Basophils
Flow cytometry (Qualified)
0.2 mg/ml
74603
AB_3689707
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  3. For U.S. patents that may apply, see bd.com/patents.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  6. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  7. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  8. When using high concentrations of antibody, background binding of this dye to erythroid fragments produced by ammonium chloride-based lysis, such as with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899), has been observed when the antibody conjugate was present during the lysis procedure. This may cause nonspecific staining of target cells, such as leukocytes, which have bound the resulting erythroid fragments. This background can be mitigated by any of the following: titrating the antibody conjugate to a lower concentration, fixing samples with formaldehyde, or removing erythrocytes before staining (eg, gradient centrifugation or pre-lysis with wash). This background has not been observed when cells were lysed with BD FACS™ Lysing Solution (Cat. No. 349202) after staining.
  9. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  10. An isotype control should be used at the same concentration as the antibody of interest.
  11. Please observe the following precautions: We recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to protect exposure of conjugated reagents, including cells stained with those reagents, to any room illumination. Absorption of visible light can significantly affect the emission spectra and quantum yield of tandem fluorochrome conjugates.
757549 Rev. 1
Antibody Details
Down Arrow Up Arrow
Ba13

The Ba13 monoclonal antibody specifically recognizes Cell surface glycoprotein CD200 receptor 3 (CD200R3) which is also known as CD200 cell surface glycoprotein receptor-like b (CD200RLb), CD200 receptor-like 3, and OX-2 Receptor 3. CD200R3 is a single-pass type I transmembrane glycoprotein that is encoded by Cd200r3 (CD200 receptor 3) which belongs to the immunoglobulin superfamily (IgSF). It is expressed on basophils and mast cells that are involved in protective immune responses against parasitic infections and in the development of allergic reactions. Cell surface CD200R3 presents as a disulfide-linked dimeric CD200R-like receptor. The cytoplasmic tail region of CD200R3 contains a positively charged lysine residue which allows this receptor to associate and signal through adaptor proteins such as DAP10, DAP12, CD3z, or FcRγ. CD200R3 functions as an activating receptor to regulate IgE-independent immune responses.

757549 Rev. 1
Format Details
Down Arrow Up Arrow
RB744
The BD Horizon RealBlue™ 744 (RB744) Dye is part of the BD® family of blue dyes. It is a tandem fluorochrome with an excitation maximum (Ex Max) at 498-nm and an emission maximum (Em Max) at 746-nm as measured using an antibody-dye conjugate. Driven by BD® innovation, RB744 can be used on both spectral and conventional cytometers and is designed to be excited by the Blue laser (488-nm) with minimal excitation by the 561-nm Yellow-Green laser. For conventional instruments equipped with a Blue laser (488-nm), we recommend using an optical filter centered near 750-nm (e.g., a 750/60-nm bandpass filter).
altImg
RB744
Blue 488 nm
498 nm
746 nm
757549 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "757549" on CiteAb

Development References (3)

  1. Kojima T, Obata K, Mukai K, et al. Mast cells and basophils are selectively activated in vitro and in vivo through CD200R3 in an IgE-independent manner.. J Immunol. 2007; 179(10):7093-100. (Biology: Flow cytometry). View Reference
  2. Nei Y, Obata-Ninomiya K, Tsutsui H, et al. GATA-1 regulates the generation and function of basophils.. Proc Natl Acad Sci U S A. 2013; 110(46):18620-5. (Clone-specific: Flow cytometry). View Reference
  3. Pellefigues C, Mehta P, Prout MS, et al. The Basoph8 Mice Enable an Unbiased Detection and a Conditional Depletion of Basophils.. Front Immunol. 2019; 10:2143. (Clone-specific: Flow cytometry). View Reference
757549 Rev. 1

Please refer to Support Documents for Quality Certificates

 

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

 

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.