RB545 Mouse Anti-Human IgG
RB545 Mouse Anti-Human IgG

Multicolor flow cytometric analysis of IgG expression on viable Human peripheral blood lymphocytes. Human peripheral blood mononuclear cells were washed and cultured in complete tissue culture medium overnight to minimize subsequent nonspecific immunofluorescent staining. The cells were harvested and stained with APC Mouse Anti-Human CD19 antibody (Cat. No. 555415/561742) and with either BD Horizon™ RB545 Mouse IgG1, κ Isotype Control (Cat. No. 569284; Left Plot) or BD Horizon™ RB545 Mouse Anti-Human IgG antibody (Cat. No. 569735/569763; Right Plot). DAPI (4',6-Diamidino-2-Phenylindole, Dihydrochloride) Solution (Cat. No. 564907) was added to cells right before analysis. The bivariate pseudocolor density plot showing the correlated expression of IgG1 (or Ig Isotype control staining) versus CD19 was derived from gated events with the forward and side light-scatter characteristics of viable (DAPI-negative) lymphocytes. Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer and spectrally unmixed using FlowJo™ v10.8 Software.

Multicolor flow cytometric analysis of IgG expression on viable Human peripheral blood lymphocytes. Human peripheral blood mononuclear cells were washed and cultured in complete tissue culture medium overnight to minimize subsequent nonspecific immunofluorescent staining. The cells were harvested and stained with APC Mouse Anti-Human CD19 antibody (Cat. No. 555415/561742) and with either BD Horizon™ RB545 Mouse IgG1, κ Isotype Control (Cat. No. 569284; Left Plot) or BD Horizon™ RB545 Mouse Anti-Human IgG antibody (Cat. No. 569735/569763; Right Plot). DAPI (4',6-Diamidino-2-Phenylindole, Dihydrochloride) Solution (Cat. No. 564907) was added to cells right before analysis. The bivariate pseudocolor density plot showing the correlated expression of IgG1 (or Ig Isotype control staining) versus CD19 was derived from gated events with the forward and side light-scatter characteristics of viable (DAPI-negative) lymphocytes. Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer and spectrally unmixed using FlowJo™ v10.8 Software.

Product Details
Down Arrow Up Arrow


BD Horizon™
IGHG1, IGHG2, IGHG3 and IGHG4
Human (QC Testing)
Mouse IgG1, κ
Flow cytometry (Routinely Tested)
5 µl/test
3500, 3501, 3502, 3503
AB_3685275
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unreacted dye was removed. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  3. An isotype control should be used at the same concentration as the antibody of interest.
  4. Please observe the following precautions: We recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to protect exposure of conjugated reagents, including cells stained with those reagents, to any room illumination. Absorption of visible light can significantly affect the emission spectra and quantum yield of tandem fluorochrome conjugates.
  5. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  8. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  9. For U.S. patents that may apply, see bd.com/patents.
569763 Rev. 2
Antibody Details
Down Arrow Up Arrow
G18-145

IgG is an important component of the humoral immune response, helping to control infection.  IgG is produced by plasma B-cells and may be found in extracellular fluids, such as blood, lymph, peritoneal, and cerebrospinal fluids.  IgG monomers consist of two light and two heavy chains containing two antigen binding sites.  There are four IgG subclasses found in human, mouse and rat species, which include IgG1, IgG2, IgG3 and IgG4.  The G18-145 monoclonal antibody specifically binds to the heavy chain of human immunoglobulin G subclasses: IgG1, IgG2, IgG3 and IgG4.  The G18-145 antibody has been reported not to react with the heavy chains of other human immunoglobulin isotypes.

569763 Rev. 2
Format Details
Down Arrow Up Arrow
RB545
The BD Horizon RealBlue™ 545 (RB545) fluorochrome is part of the BD family of blue (488-nm) laser dyes. It is a small organic fluorochrome with an excitation maximum (Ex Max) at 496-nm and an emission maximum (Em Max) at 545-nm. Driven by BD innovation, RB545 can be used on spectral cytometers and is designed to be excited by the blue (488-nm) laser with minimal excitation by the 561-nm yellow-green laser. RB545 has minimal spillover into yellow-green detectors and a brightness level similar to FITC.  Given its unique emission max, on a spectral instrument RB545 can be used simultaneously with FITC and PE to provide an additional color off of the blue laser. Please ensure that your instrument configuration (lasers and optical filters) is appropriate for this dye.
altImg
RB545
Blue 488 nm
496 nm
545 nm
569763 Rev.2
Citations & References
Down Arrow Up Arrow
View product citations for antibody "569763" on CiteAb

Development References (4)

  1. Jourdan M, Caraux A, Caron G, et al. Characterization of a transitional preplasmablast population in the process of human B cell to plasma cell differentiation. J Immunol. 2011; 187(8):3931-3941. (Clone-specific: Flow cytometry). View Reference
  2. Odendahl M, Mei H, Hoyer BF, et al. Generation of migratory antigen-specific plasma blasts and mobilization of resident plasma cells in a secondary immune response. Blood. 2005; 105(4):1614-1621. (Clone-specific: Flow cytometry). View Reference
  3. Roll P, Palanichamy A, Kneitz C, Dorner T, Tony HP. Regeneration of B cell subsets after transient B cell depletion using anti-CD20 antibodies in rheumatoid arthritis. Arthritis Rheum. 2006; 54(8):2377-2386. (Clone-specific: Flow cytometry). View Reference
  4. Scheeren FA, Naspetti M, Diehl S, et al. STAT5 regulates the self-renewal capacity and differentiation of human memory B cells and controls Bcl-6 expression. Nat Immunol. 2005; 6(3):303-313. (Clone-specific: Flow cytometry). View Reference
View All (4) View Less
569763 Rev. 2

Please refer to Support Documents for Quality Certificates

 

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

 

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.