Skip to main content Skip to navigation
RB545 Mouse Anti-Human CD28
Product Details
Down Arrow Up Arrow


BD OptiBuild™
CD28 antigen; T44; Tp44; TP44; Leu28
Human (Tested in Development)
Mouse BALB/c IgG1, κ
HPB-ALL T cell line
Flow cytometry (Qualified)
0.2 mg/ml
AB_3688723
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Please observe the following precautions: Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  5. An isotype control should be used at the same concentration as the antibody of interest.
  6. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  7. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  8. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  9. Researchers should determine the optimal concentration of this reagent for their individual applications.
  10. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
756493 Rev. 1
Antibody Details
Down Arrow Up Arrow
L293

The L293 monoclonal antibody specifically binds to CD28 which is also known as Tp44 or T44. The CD28 antigen is a 44 kDa homodimeric type I transmembrane glycoprotein which is present on most mature T cells, thymocytes, and plasma cells. CD28 is a cell-adhesion molecule (CAM) that functions as a receptor for CD80 (B7-1) and CD86 (B7-2) antigens, which are present on activated B lymphocytes, monocytes, and dendritic cells. Interaction of the CD28 antigen with CD80 or CD86 antigens, or both, co-stimulates CD2 and CD3 antigen/T-cell antigen receptor (TCR)-dependent T-cell-mediated proliferation and cytotoxicity. The L293 antibody has been demonstrated to bind to the same molecule as clone CD28.2, another CD28-specific antibody.

756493 Rev. 1
Format Details
Down Arrow Up Arrow
RB545
The BD Horizon RealBlue™ 545 (RB545) fluorochrome is part of the BD family of blue (488-nm) laser dyes. It is a small organic fluorochrome with an excitation maximum (Ex Max) at 496-nm and an emission maximum (Em Max) at 545-nm. Driven by BD innovation, RB545 can be used on spectral cytometers and is designed to be excited by the blue (488-nm) laser with minimal excitation by the 561-nm yellow-green laser. RB545 has minimal spillover into yellow-green detectors and a brightness level similar to FITC.  Given its unique emission max, on a spectral instrument RB545 can be used simultaneously with FITC and PE to provide an additional color off of the blue laser. Please ensure that your instrument configuration (lasers and optical filters) is appropriate for this dye.
altImg
RB545
Blue 488 nm
496 nm
545 nm
756493 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "756493" on CiteAb
No Citations Found

No Citations Are Available for this Product

756493 Rev. 1

Please refer to Support Documents for Quality Certificates

 

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

 

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.