Skip to main content Skip to navigation
RB545 Mouse Anti-Human CD90 (Thy-1)
RB545 Mouse Anti-Human CD90 (Thy-1)
Multicolor flow cytometric analysis of CD90 (Thy-1) expression on Human peripheral blood lymphocytes.  Human peripheral blood mononuclear cells (PBMC) were stained with APC Mouse Anti-Human CD34 antibody (Cat. No. 555824/560940) and with either BD Horizon™ RB545 Mouse IgG1, κ Isotype Control (Cat. No. 569284; Left Plot) or BD Horizon™ RB545 Mouse Anti-Human CD90 (Thy-1) antibody (Cat. No. 569731/569759; Right Plot). DAPI (4',6-Diamidino-2-Phenylindole, Dihydrochloride) Solution (Cat. No. 564907) was added to cells right before analysis. The bivariate pseudocolor density plot showing the correlated expression of CD90 (Thy-1) [or Ig Isotype control staining] versus CD34 was derived from gated events with the forward and side light-scatter characteristics of viable (DAPI-negative) lymphocytes. Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer and spectrally unmixed using FlowJo™ v10.8 software.
RB545 Mouse Anti-Human CD90 (Thy-1)
Flow cytometric analysis of CD90 (Thy-1) expression on Human HEL cells. Cells from the HEL (Human erythroleukemia, ATCC® TIB-180™) cell line were stained with BD Horizon™ RB545 Mouse IgG1, κ Isotype Control (Cat. No. 569284; dashed line histogram) or BD Horizon™ RB545 Mouse Anti-Human CD90 (Thy-1) antibody (Cat. No. 569731/569759; solid line histogram). DAPI Solution (Cat. No. 564907) was added to cells right before analysis. The fluorescence histogram showing CD90 (Thy-1) expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of viable (DAPI-negative) cells. Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer and spectrally unmixed using FlowJo™ v10.8 software.
Multicolor flow cytometric analysis of CD90 (Thy-1) expression on Human peripheral blood lymphocytes.  Human peripheral blood mononuclear cells (PBMC) were stained with APC Mouse Anti-Human CD34 antibody (Cat. No. 555824/560940) and with either BD Horizon™ RB545 Mouse IgG1, κ Isotype Control (Cat. No. 569284; Left Plot) or BD Horizon™ RB545 Mouse Anti-Human CD90 (Thy-1) antibody (Cat. No. 569731/569759; Right Plot). DAPI (4',6-Diamidino-2-Phenylindole, Dihydrochloride) Solution (Cat. No. 564907) was added to cells right before analysis. The bivariate pseudocolor density plot showing the correlated expression of CD90 (Thy-1) [or Ig Isotype control staining] versus CD34 was derived from gated events with the forward and side light-scatter characteristics of viable (DAPI-negative) lymphocytes. Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer and spectrally unmixed using FlowJo™ v10.8 software.
Flow cytometric analysis of CD90 (Thy-1) expression on Human HEL cells. Cells from the HEL (Human erythroleukemia, ATCC® TIB-180™) cell line were stained with BD Horizon™ RB545 Mouse IgG1, κ Isotype Control (Cat. No. 569284; dashed line histogram) or BD Horizon™ RB545 Mouse Anti-Human CD90 (Thy-1) antibody (Cat. No. 569731/569759; solid line histogram). DAPI Solution (Cat. No. 564907) was added to cells right before analysis. The fluorescence histogram showing CD90 (Thy-1) expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of viable (DAPI-negative) cells. Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer and spectrally unmixed using FlowJo™ v10.8 software.
Product Details
Down Arrow Up Arrow


BD Horizon™
THY1; Thy-1 antigen; Thy-1 membrane glycoprotein
Human (QC Testing), Rhesus,Cynomolgus,Baboon,Pig,Dog (Tested in Development)
Mouse BALB/c IgG1, κ
Human HEL Cell Line
Flow cytometry (Routinely Tested)
5 µl/test
V M07, BP222; VI BP28, E046
7070
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unreacted dye was removed.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  3. An isotype control should be used at the same concentration as the antibody of interest.
  4. Please observe the following precautions: Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
  5. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. Species cross-reactivity detected in product development may not have been confirmed on every format and/or application.
  8. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  9. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  10. For U.S. patents that may apply, see bd.com/patents.
569731 Rev. 1
Antibody Details
Down Arrow Up Arrow
5E10

The 5E10 monoclonal antibody specifically binds to human CD90 which is also known as Thy-1. CD90 is a 25-35 kDa glycophosphatidylinositol-anchored membrane glycoprotein of the Ig superfamily that is expressed on 1-4% of human fetal liver cells, cord blood cells, and bone marrow cells. The anti-CD90 antibody binds to a subset of immature CD34+ cells and a distinct subset of mature CD34- cells that are CD3+CD4+. The CD90+CD34+ population is highly enriched for cells capable of long-term culture. The anti-CD90 antibody is useful for enriching high proliferative potential colony-forming cells (HIPP-CFC) that are primative progenitor cells.

569731 Rev. 1
Format Details
Down Arrow Up Arrow
RB545
The BD Horizon RealBlue™ 545 (RB545) fluorochrome is part of the BD family of blue (488-nm) laser dyes. It is a small organic fluorochrome with an excitation maximum (Ex Max) at 496-nm and an emission maximum (Em Max) at 545-nm. Driven by BD innovation, RB545 can be used on spectral cytometers and is designed to be excited by the blue (488-nm) laser with minimal excitation by the 561-nm yellow-green laser. RB545 has minimal spillover into yellow-green detectors and a brightness level similar to FITC.  Given its unique emission max, on a spectral instrument RB545 can be used simultaneously with FITC and PE to provide an additional color off of the blue laser. Please ensure that your instrument configuration (lasers and optical filters) is appropriate for this dye.
altImg
RB545
Blue 488 nm
496 nm
545 nm
569731 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "569731" on CiteAb

Development References (7)

  1. Baum CM, Weissman IL, Tsukamoto AS, Buckle AM, Peault B. Isolation of a candidate human hematopoietic stem-cell population. Proc Natl Acad Sci U S A. 1992; 89(7):2804-2808. (Biology). View Reference
  2. Craig W, Kay R, Cutler RL, Lansdorp PM. Expression of Thy-1 on human hematopoietic progenitor cells. J Exp Med. 1993; 177(5):1331-1342. (Immunogen: Flow cytometry, Immunoprecipitation, Western blot). View Reference
  3. Kishimoto T. Tadamitsu Kishimoto .. et al., ed. Leucocyte typing VI : white cell differentiation antigens : proceedings of the sixth international workshop and conference held in Kobe, Japan, 10-14 November 1996. New York: Garland Pub.; 1997.
  4. Knapp W. W. Knapp .. et al., ed. Leucocyte typing IV : white cell differentiation antigens. Oxford New York: Oxford University Press; 1989:1-1182.
  5. Lansdorp PM, Thomas TE. AP Gee, ed. Bone Marrow Processing and Purging. Boca Raton FL: CRC Press; 1991.
  6. Lin G-X, Yang X, Hollemweguer E, et al. Cross-reactivity of CD antibodies in eight animal species. In: Mason D. David Mason .. et al., ed. Leucocyte typing VII : white cell differentiation antigens : proceedings of the Seventh International Workshop and Conference held in Harrogate, United Kingdom. Oxford: Oxford University Press; 2002:519-523.
  7. Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995.
View All (7) View Less
569731 Rev. 1

Please refer to Support Documents for Quality Certificates

 

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

 

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.