BB515 Mouse Anti-Human GPR56
BB515 Mouse Anti-Human GPR56
Multicolor flow cytometric analysis of GPR56 expression on human peripheral blood lymphocytes. Human whole blood was stained with APC Mouse Anti-Human CD56 (Cat. No. 555518) and either BD Horizon™ BB515 Mouse IgG1, κ Isotype Control (Cat. No. 564416; Left Plot) or BD Horizon™ BB515 Mouse Anti-Human GPR56 antibody (Cat. No. 567616/567619; Right Plot). Erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202). The bivariate pseudocolor density plots showing either GPR56 [or Ig isotype control] staining versus CD56 were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software.
Multicolor flow cytometric analysis of GPR56 expression on human peripheral blood lymphocytes. Human whole blood was stained with APC Mouse Anti-Human CD56 (Cat. No. 555518) and either BD Horizon™ BB515 Mouse IgG1, κ Isotype Control (Cat. No. 564416; Left Plot) or BD Horizon™ BB515 Mouse Anti-Human GPR56 antibody (Cat. No. 567616/567619; Right Plot). Erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202). The bivariate pseudocolor density plots showing either GPR56 [or Ig isotype control] staining versus CD56 were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software.
Product Details
Down Arrow Up Arrow


BD Horizon™
G protein-coupled receptor 56; ADGRG1; BFPP; BPPR; TM7LN4; TM7XN1; testicular tissue protein Li 77
Human (QC Testing), Mouse (Reported)
Mouse BALB/c IgG1, κ
Human GPR56 Recombinant Protein
Flow cytometry (Routinely Tested)
5 µl
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unconjugated antibody and free dye were removed.

Recommended Assay Procedures

  BD® CompBeads can be used as surrogates to assess fluorescence spillover (Compensation). When fluorochrome conjugated antibodies are bound to CompBeads, they have spectral properties very similar to cells.  However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and CompBead to ensure that BD® CompBeads are appropriate for your specific cellular application.

For optimal and reproducible results, BD Horizon Brilliant™ Stain Buffer should be used anytime BD Horizon Brilliant™ dyes are used in a multicolor flow cytometry panel. Fluorescent dye interactions may cause staining artifacts which may affect data interpretation. The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. When BD Horizon Brilliant Stain Buffer is used in in the multicolor panel, it should also be used in the corresponding compensation controls for all dyes to achieve the most accurate compensation. For the most accurate compensation, compensation controls created with either cells or beads should be exposed to BD Horizon Brilliant Stain Buffer for the same length of time as the corresponding multicolor panel. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).

For optimal results, it is recommended to perform two washes after staining with antibodies. Cells may be prepared, stained with antibodies and washed twice with wash buffer per established protocols for immunofluorescence staining, prior to acquisition on a flow cytometer. Performing fewer than the recommended wash steps may lead to increased spread of the negative population.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  7. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  8. Alexa Fluor™ is a trademark of Life Technologies Corporation.
567616 Rev. 1
Antibody Details
Down Arrow Up Arrow
CG4.rMAb

  The CG4.rMab is a recombinant monoclonal antibody that was derived from CG4 hybridoma cells. The CG4.rMab specifically binds to human G-protein coupled receptor 56 (GPR56) like the conventional CG4 antibody and performs like the CG4 antibody when used to stain cells and analyze them by flow cytometry. GPR56 is also known as adhesion G-protein coupled receptor G1 (ADGRG1), or TM7XN1. GPR56 is a ~15kDa G protein-coupled receptor encoded by ADGRG1 which belongs to the adhesion-GPCR family that comprises 33 members in human. The extracellular region contains a mucin-like domain followed by a membrane proximal GPCR-autoproteolysis inducing (GAIN) domain, seven transmembrane regions and a cytoplasmic tail. The constitutive self-cleavage at the proteolytic site gives rise to a membrane spanning (C-terminal fragment or CTF) and an extracellular (N-terminal fragment or NTF) subunit that remain noncovalently bound, leading to the expression of a heterodimeric receptor at the cell surface. GPR56 is widely expressed with the highest levels of messenger found in the brain, heart, and thyroid gland. Recently, GPR56 was found to be variably expressed on platelets, cytotoxic NK cells and T lymphocytes including CD4+, CD8+, and γδ T cells. It was shown that GPR56 functions as an inhibitory receptor on NK cells through interaction with CD81. While GPR56 NTF associates with Tissue transglutaminase 2 and Collagen III (α-1), GPR56 CTF can recruit Gα proteins leading to the activation of mTOR and RhoA signaling pathways. GPR56 has been implicated in cell-cell interactions, adhesion, migration, and regulation of cell proliferation and survival of various cell types. New evidence also shows a role of GPR56 in tumor progression. Recently, the CG4 antibody was found to activate GPR56 in melanoma cells leading to an increase of IL-6 secretion, in a CD9/CD81-dependent manner.

The antibody was conjugated to BD Horizon™ BB515 which is part of the BD Horizon Brilliant™ Blue family of dyes. With an Ex Max near 490 nm and an Em Max near 515 nm, BD Horizon™ BB515 can be excited by the blue laser (488 nm) laser and detected with a 530/30 nm filter. This dye has been exclusively developed by BD Biosciences and is up to seven times brighter than FITC with less spillover into the PE channel. Due to similar excitation and emission properties, BB515, FITC, and Alexa Fluor™ 488 cannot be used simultaneously. It is not recommended to use BB515 in cocktails that include Streptavidin conjugates as it may cause high background.

567616 Rev. 1
Format Details
Down Arrow Up Arrow
BB515
The BD Horizon Brilliant™ Blue 515 (BB515) dye is part of the BD Horizon Brilliant™ Blue family of dyes. This dye is a polymer fluorochrome with an excitation maximum (Ex Max) at 490-nm and an emission maximum (Em Max) of 515-nm. Driven by BD innovation, BB515 is designed to be excited by the blue laser (488-nm) and detected using an optical filter centered near 520-nm (e.g., 530/30-nm). BB515 reagents are significantly brighter than equivalent FITC or Alexa Fluor™ 488 reagents with less spillover into the PE detector. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BB515
Blue 488 nm
490 nm
515 nm
567616 Rev.1
Citations & References
Down Arrow Up Arrow

Development References (6)

  1. Della Chiesa M, Falco M, Parolini S, et al. GPR56 as a novel marker identifying the CD56dull CD16+ NK cell subset both in blood stream and in inflamed peripheral tissues.. Int Immunol. 2010; 22(2):91-100. (Biology: Flow cytometry). View Reference
  2. Liu M, Parker RM, Darby K, et al. GPR56, a novel secretin-like human G-protein-coupled receptor gene.. Genomics. 1999; 55(3):296-305. (Biology). View Reference
  3. Pabst C, Bergeron A, Lavallée VP, et al. GPR56 identifies primary human acute myeloid leukemia cells with high repopulating potential in vivo.. Blood. 2016; 127(16):2018-27. (Clone-specific: Flow cytometry). View Reference
  4. Peng YM, van de Garde MD, Cheng KF, et al. Specific expression of GPR56 by human cytotoxic lymphocytes.. J Leukoc Biol. 2011; 90(4):735-40. (Immunogen: Flow cytometry). View Reference
  5. Piao X, Hill RS, Bodell A, et al. G protein-coupled receptor-dependent development of human frontal cortex.. Science. 2004; 303(5666):2033-6. (Biology). View Reference
  6. Rao TN, Marks-Bluth J, Sullivan J, et al. High-level Gpr56 expression is dispensable for the maintenance and function of hematopoietic stem and progenitor cells in mice.. Stem Cell Res. 2015; 14(3):307-22. (Clone-specific: Flow cytometry). View Reference
View All (6) View Less
567616 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.