Skip to main content Skip to navigation
PE Rat IgG2a κ Isotype Control
Alert icon
Consider BD Horizon RealYellow™ 586 (RY586) Reagents, a bright and clean fluorochrome alternative to PE off the yellow-green laser. RY586 can be used alongside PE on spectral cytometers. More Info #
Product Details
Down Arrow Up Arrow


BD Pharmingen™
Rat LOU, also known as Louvain, LOU/C, LOU/M IgG2a, κ
Mouse Pooled Immunoglobulin
Intracellular staining (flow cytometry), Isotype control (Routinely Tested)
20 µl
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation And Storage

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with R-PE under optimum conditions, and unconjugated antibody and free PE were removed. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

Recommended Assay Procedures

I/C Flow Cytometry: The PE-conjugated R35-95 immunoglobulins (Cat. No. 559317) is a suitable rat IgG2a κ isotype controls for assessing the level of background staining on paraformaldehyde-fixed/saponin-permeabilized mouse or human cells for flow cytometric analysis.

Important Note: This pre-titered antibody solution does not contain a cell permeabilization agent. It is necessary to include a cell permeabilization agent when using the pre-titered antibody solution to stain fixed and permeabilized cells. BD Perm/Wash™ Buffer (Cat. No 554723) contains the permeabilization agent saponin and is useful for this purpose as described in the Protocol section below.

Protocol

1. Resuspend 1 x 10^6 fixed and permeabilized cells in 20 µl of the pre-titered antibody solution and 30 µl of 1X Perm/Wash Buffer (Cat. No 554723).

2. Incubate the cell suspension for 15 minutes (at RT or 4°C).

3. Wash twice in 100 µl of 1X Perm/Wash Buffer (Cat. No 554723).

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  3. An isotype control should be used at the same concentration as the antibody of interest.
  4. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  5. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  6. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  7. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
559317 Rev. 2
Antibody Details
Down Arrow Up Arrow
R35-95

The R35-95 hybridoma was generated by hybridization of Y3 myeloma cells with spleen cells from LOU rats immunized with mouse immunoglobulins. The R35-95 hybridoma produces rat IgG2a, κ immunoglobulin that has no measurable reactivity with mouse immunoglobulins. The R35-95 immunoglobulin was selected as an isotype control following screening for low background binding on a variety of mouse and human tissues.

559317 Rev. 2
Format Details
Down Arrow Up Arrow
PE
R-Phycoerythrin (PE), is part of the BD family of Phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 496 nm and 566 nm and an emission maximum (Em Max) at 576 nm. PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 575/26-nm bandpass filter). As PE is excited by multiple lasers, this can result in cross-laser excitation and fluorescence spillover on instruments with various combinations of Blue, Green, and Yellow-Green lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
576 nm
559317 Rev.2
Citations & References
Down Arrow Up Arrow

Development References (1)

  1. Prussin C, Metcalfe DD. Detection of intracytoplasmic cytokine using flow cytometry and directly conjugated anti-cytokine antibodies. J Immunol Methods. 1995; 188(1):117-128. (Biology). View Reference
559317 Rev. 2

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.