Skip to main content Skip to navigation
R718 Mouse Anti-Human CD273 (PD-L2)
R718 Mouse Anti-Human CD273 (PD-L2)
Flow cytometric analysis of CD273 (PD-L2) expression on viable Human monocyte-derived mature dendritic cells.  Human monocyte-derived mature dendritic cells were stained with either BD Horizon™ R718 Mouse IgG1, κ Isotype Control (Cat. No. 566928; dashed line histogram) or BD Horizon™ R718 Mouse Anti-Human CD273 (PD-L2) antibody (Cat. No. 570058/570139; solid line histogram). DAPI Solution (Cat. No. 564907) was added to cells right before analysis. The fluorescence histogram showing CD273 (PD-L2) expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of viable (DAPI-negative) cells. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ Software.
Flow cytometric analysis of CD273 (PD-L2) expression on viable Human monocyte-derived mature dendritic cells.  Human monocyte-derived mature dendritic cells were stained with either BD Horizon™ R718 Mouse IgG1, κ Isotype Control (Cat. No. 566928; dashed line histogram) or BD Horizon™ R718 Mouse Anti-Human CD273 (PD-L2) antibody (Cat. No. 570058/570139; solid line histogram). DAPI Solution (Cat. No. 564907) was added to cells right before analysis. The fluorescence histogram showing CD273 (PD-L2) expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of viable (DAPI-negative) cells. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ Software.
Product Details
Down Arrow Up Arrow


BD Horizon™
CD273; PD-L2; PDL2; PDCD1LG2; B7-DC; B7DC
Human (QC Testing)
Mouse IgG1, λ1
Human PD-L2 cDNA
Flow cytometry (Routinely Tested)
5 µl/test
80380
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unreacted dye was removed. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  3. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  4. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  5. An isotype control should be used at the same concentration as the antibody of interest.
  6. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  7. This product is provided under an Agreement between BIOTIUM and BD Biosciences. This product, and only in the amount purchased by buyer, may be used solely for buyer’s own internal research, in a manner consistent with the accompanying product literature. No other right to use, sell or otherwise transfer (a) this product, or (b) its components is hereby granted expressly, by implication or by estoppel. This product is for research use only. Diagnostic uses require a separate license from Biotium, Inc. For information on purchasing a license to this product including for purposes other than research, contact Biotium, Inc., 3159 Corporate Place, Hayward, CA 94545, Tel: (510) 265-1027. Fax: (510) 265-1352. Email: btinfo@biotium.com.
  8. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  9. Clones without a listed workshop have not been investigated in an HLDA workshop to receive a CD nomenclature. We use “CD” provisionally when our internal testing indicates that this clone binds to the same CD antigen as workshopped clones.
  10. Alexa Fluor™ is a trademark of Life Technologies Corporation.
  11. For U.S. patents that may apply, see bd.com/patents.
570058 Rev. 1
Antibody Details
Down Arrow Up Arrow
IPI683.rMab

The IPI683.rMAb recombinant monoclonal antibody specifically recognizes Programmed cell death 1 ligand 2 (PD-L2) which is also known as CD273 and Butyrophilin B7-DC (B7-DC). This regulatory molecule is a 42-kDa type I membrane glycoprotein encoded by PDCD1LG2 which belongs to the B7 family of the Ig superfamily. CD273 (PD-L2) is comprised of an extracellular region with an N-terminal IgV-like domain followed by an IgC2-type domain, a transmembrane sequence, and a cytoplasmic tail. Although not detected on resting leucocytes, its expression is upregulated upon activation of macrophages and dendritic cells (DC) by a variety of stimulatory factors including IL-4, IL-13, or GM-CSF. CD273 (PD-L2) has been recognized as an inhibitory regulator of human T-cell activation and serves as a ligand for the coinhibitory receptor, CD279 (PD-1), a receptor that likewise binds to the CD274 (PD-L1) ligand. CD273 (PD-L2) also binds to Repulsive guidance molecule b (RGMb) that is expressed by T cells, macrophages, neutrophils, and DC. RGMb may associate with other receptors that transduce costimulatory or coinhibitory signals.

570058 Rev. 1
Format Details
Down Arrow Up Arrow
R718
The BD Horizon™ Red 718 (R718) Dye is part of the BD red family of dyes. It is a small organic fluorochrome with an excitation maximum (Ex Max) at 695-nm and an emission maximum (Em Max) at 718-nm. Driven by BD innovation, R718 is designed to be excited by the red laser (627–640-nm) and detected using an optical filter centered near 720-nm (e.g., a 720/40-nm bandpass filter). R718 is a brighter alternative to Alexa Fluor™ 700. R718 is also a bright small molecule alternative to APC-R700 with lower spread into the APC detector. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
R718
Red 627-640 nm
695 nm
718 nm
570058 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "570058" on CiteAb

Development References (3)

  1. Brown JA, Dorfman DM, Ma FR, et al. Blockade of programmed death-1 ligand on dendritic cells enhances T cell activation and cytokine production. J Immunol. 2003; 170:1257-1266. (Biology). View Reference
  2. Pfistershammer K, Klauser C, Pickl WF, et al. No evidence for dualism in function and receptors: PD-L2/B7-DC is an inhibitory regulator of human T cell activation. Eur J Immunol. 2006; 36(5):1104-1113. (Biology). View Reference
  3. Rodig N, Ryan T, Allen JA, et al. Endothelial expression of PD-L1 and PD-L2 down-regulates CD8+ T cell activation and cytolysis.. Eur J Immunol. 2003; 33(11):3117-26. (Biology). View Reference
570058 Rev. 1

Please refer to Support Documents for Quality Certificates

 

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

 

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.