The site is undergoing maintenance on
Thursday, September 10, 2026, 12:00 - 8:00 pm (EDT).
If you encounter problems while ordering, please contact us at BDBCustomerService@bd.com
See More
The site is undergoing maintenance on
Thursday, September 10, 2026, 12:00 - 8:00 pm (EDT).
If you encounter problems while ordering, please contact us at BDBCustomerService@bd.com
See MoreThe site is undergoing maintenance on
Thursday, September 10, 2026, 12:00 - 8:00 pm (EDT)
.If you encounter problems while ordering, please contact us at BDBCustomerService@bd.com
Looks like you're visiting us from {countryName}.
Would you like to stay on the current country site or be switched to your country?
Top: Schematic workflow of the human MSC analysis kit.
Bottom: Cells grown in BD Mosaic™ hMSC SF Cell Culture Environment (Cat. No. 355700) were detached using BD™ Accutase™ Cell Detachment Solution (Cat. No 561527) and then stained with the positive and negative cocktails (solid lines) or the positive and negative isotype control cocktails (dashed lines). The plots were derived from gated events based on light scattering characteristics of the MSCs. Cells were analyzed using a BD™ LSRII flow cytometry system.
Top: Schematic workflow of the human MSC analysis kit.
Bottom: Cells grown in BD Mosaic™ hMSC SF Cell Culture Environment (Cat. No. 355700) were detached using BD™ Accutase™ Cell Detachment Solution (Cat. No 561527) and then stained with the positive and negative cocktails (solid lines) or the positive and negative isotype control cocktails (dashed lines). The plots were derived from gated events based on light scattering characteristics of the MSCs. Cells were analyzed using a BD™ LSRII flow cytometry system.
Top: Schematic workflow of the human MSC analysis kit.
Bottom: Cells grown in BD Mosaic™ hMSC SF Cell Culture Environment (Cat. No. 355700) were detached using BD™ Accutase™ Cell Detachment Solution (Cat. No 561527) and then stained with the positive and negative cocktails (solid lines) or the positive and negative isotype control cocktails (dashed lines). The plots were derived from gated events based on light scattering characteristics of the MSCs. Cells were analyzed using a BD™ LSRII flow cytometry system.
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Human multipotent mesenchymal stromal cells (MSCs), also referred to as mesenchymal stem cells, are a rare population of adult stem cells that can be isolated from a variety of tissues. MSCs that have been isolated from bone marrow and subsequently cultured can differentiate to a variety of cell types, most notably adipocytes, osteocytes and chondrocytes. MSCs also have immunomodulatory effects in vivo and in vitro. In 2006, the International Society for Cellular Therapy (ISCT) proposed a cell surface marker panel for the minimal identification of human MSCs derived from bone marrow. Under this recommendation MSCs should be positive for CD73, CD90, and CD105, but be negative for CD34, CD45, CD11b or CD14, CD19 or CD79α, and HLA-DR. MSCs are also known to express numerous cell surface markers such as CD44, CD29, CD200, CD166, CD146 and CD271. In this kit we include the panel that was proposed by the ISCT. In addition, we designed this kit to be modular so that additional markers could be "dropped-in". Specifically, the MSC positive cocktail (FITC CD90, PerCP-Cy™5.5 CD105 and APC CD73) leaves the PE channel open to use in combination with the supplied negative MSC cocktail (PE CD45, PE CD34, PE CD11b, PE CD19 and PE HLA-DR), the included PE CD44 antibody conjugate, or a variety of other commercially available PE antibody conjugates. Multi color analysis minimizes cell numbers required for an assay and antibody cocktails facilitate a streamlined staining protocol to analyze multiple samples. Individual positive markers are included for compensation set-up.
Kit Components
Component Description Size Vol. Per Test Storage Buffer
51-9007661 PE hMSC Negative Cocktail 50 Test 20 µl Aqueous buffered solution containing
BSA and ≤0.09% sodium azide
51-9007662 PE hMSC Isotype Control Negative Cocktail 50 Test 20 µl Aqueous buffered solution containing
BSA and ≤0.09% sodium azide
51-9007663 hMSC Positive Cocktail 50 Test 20 µl Aqueous buffered solution containing
BSA and ≤0.09% sodium azide
51-9007664 hMSC Isotype Control Positive Cocktail 50 Test 20 µl Aqueous buffered solution containing
BSA and ≤0.09% sodium azide
51-9007657 FITC Mouse Anti-Human CD90 50 Test 5 µl Aqueous buffered solution containing
BSA and ≤0.09% sodium azide
51-9007656 PE Mouse Anti-Human CD44 100 Test 5 µl Aqueous buffered solution containing BSA,
protein stabilizer, and ≤0.09% sodium azide
51-9007655 PE Mouse IgG2b, k Isotype Control 50 Test 5 µl Aqueous buffered solution containing
BSA and ≤0.09% sodium azide
51-9007649 APC Mouse Anti-Human CD73 50 Test 5 µl Aqueous buffered solution containing
BSA and ≤0.09% sodium azide
51-9007648 PerCP-Cy™5.5 Mouse Anti-Human CD105 50 Test 5 µl Aqueous buffered solution containing
(Endoglin) BSA and ≤0.09% sodium azide
Description of Kit Components
Vial Contents Purpose
hMSC Positive Cocktail CD90 FITC (Clone: 5E10) Cocktail to positively identify hMSCs
CD105 PerCP-Cy5.5 (Clone: 266)
CD73 APC (Clone: AD2)
hMSC Positive Isotype Control Cocktail mIgG1, κ FITC (Clone: X40) Corresponding Isotype Control for hMSC Positive mIgG1, κ PerCP-Cy5.5 (Clone: X40) Cocktail
mIgG1, κ APC (Clone: X40)
PE hMSC Negative Cocktail CD34 PE (Clone:581) Cocktail to identify potential contaminants
CD11b PE (Clone: ICRF44)
CD19 PE (Clone: HIB19)
CD45 PE (Clone: HI30)
HLA-DR PE (Clone: G46-6)
PE hMSC Negative Isotype Control Cocktail mIgG1, κ PE (Clone: X40) Corresponding isotype control for PE hMSC
mIgG2a, κ PE (Clone:G155-178) Negative Cocktail
FITC Mouse Anti-human CD90 CD90 FITC (Clone: 5E10) Compensation control
PE Mouse Anti-Human CD44 CD44 PE (Clone: G44-26) Compensation control/MSC positive drop-in
PerCP-Cy™5.5 Mouse Anti-Human CD105 CD105 PerCP-Cy™5.5 (Clone: 266) Compensation control
APC Mouse Anti-Human CD73 CD73 APC (Clone:AD2) Compensation control
PE Mouse IgG2b, κ Isotype Control mIgG2b, κ (Clone: 27-35) Corresponding Isotype Control for PE Mouse
Anti-Human CD44, when used as a drop in
(1) Detach cells using BD™ Accutase™ Cell Detachment Solution (Cat. No 561527) or similar detachment solution, wash cells and resuspend at
a concentration of 1x10^7 cells/ml in BD Pharmingen™ Stain Buffer (Cat. No. 554656) or other appropriate staining buffer.
(a) Cells can also be resuspended at a concentration of 5x10^6 cells/ml if cell number is a limiting factor.
(2) Label tubes and add antibodies as shown below:
Tube Add (1 test size)
(1) FITC Mouse Anti-Human CD90 (5µl)
(2) PE Mouse Anti-Human CD44 (5µl)
(3) PerCP-Cy™5.5 Mouse Anti-Human CD105 (5µl)
(4) APC Mouse Anti-Human CD73 (5µl)
(5) Nothing
(6) hMSC Positive Isotype Control Cocktail (20µl)
PE hMSC Negative Isotype Control Cocktail (20µl)
(7) hMSC Positive Cocktail (20µl)
PE hMSC Negative Cocktail (20µl)
And/or
(8) hMSC Positive Isotype Control Cocktail (20µl)
Drop in isotype control (i.e. PE Mouse IgG2b, κ) (5 µl)
(9) hMSC Positive Cocktail (20µl)
PE Drop in (i.e. PE Mouse Anti-Human CD44) (5µl)
(3) Repeat tubes 5-7 and/or 8-9 for each additional cell sample.
(4) Add 100 µl of prepared cell suspension to tubes 1 through 9.
(5) Incubate tubes in the dark for 30 minutes (May be done on ice or at room temp)
(6) Wash the cells twice with BD Pharmingen™ Stain Buffer (FBS) and resuspend at 300-500 µl in BD Pharmingen™ Stain Buffer (FBS) .
Alternatively, 1X Washing/Staining Solution (1 x PBS,1% FCS, and 0.09% sodium azide) may be used.
(7) Analyze cells on flow cytometer
(a) tubes 1-5 are to be used as controls to set up cytometer (i.e Compensation)
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.